The implementation of chloramine disinfection introduces free ammonia into drinking water distribution systems, and free ammonia serves as an energy source for ammonia oxidizing bacteria that cause nitrification. The occurrence of nitrification may be affected by many factors including temperature, pH, water age, chloramine residual, and chlorine-to-ammonia application ratio. No studies have been conducted to quantitatively evaluate the individual and total contributions of these factors to the risk of nitrification occurrence. This study evaluated the individual and total contributions of pH and other factors on nitrification occurrence using factorial-designed pilot-scale chloraminated distribution system experiments. The pilot-scale systems were operated at pH values of approximately 7.0, 8.0, and 9.0. Logistic models were developed to quantify the contribution of pH and other factors to the risk of nitrification occurrence in the pilot-scale systems. Results showed that pH, total chlorine residual, hydraulic detention time, and temperature were the significant factors that influenced the risk of nitrification occurrence. However, none of these factors appeared to be dominant in predicting the risk of nitrification occurrence under the studied conditions. A simplified model was able to predict the risk of nitrification occurrence in the pilot-scale systems based on a combination of pH, temperature, and total chlorine residual. The developed logistic models provide an easy-to-use tool for drinking water utilities to manage operation strategies to minimize the risk of nitrification occurrence based on ambient conditions (temperature and pH) and operating parameters (water age and chloramine residual).
Skip Nav Destination
Article navigation
August 2007
This article was originally published in
Journal of Water Supply: Research and Technology-Aqua
Article Contents
Research Article|
August 01 2007
Risk analysis of nitrification occurrence in pilot-scale chloraminated distribution systems
Jian Yang;
1Earth Tech Inc., 200 Indiana Ave., Stevens Point, WI 54481, USA
Tel.: 715/342-3052; Fax: 715/341-7390; E-mail: [email protected]
Search for other works by this author on:
Gregory W. Harrington;
Gregory W. Harrington
2Department of Civil and Environmental Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
Search for other works by this author on:
Daniel R. Noguera;
Daniel R. Noguera
2Department of Civil and Environmental Engineering, University of Wisconsin-Madison, Madison, WI 53706, USA
Search for other works by this author on:
Kala K. Fleming
Kala K. Fleming
3American Water, 1025 Laurel Oak Rd., Voorhees, NJ 08043, USA
Search for other works by this author on:
Journal of Water Supply: Research and Technology-Aqua (2007) 56 (5): 293–311.
Article history
Received:
April 17 2007
Accepted:
April 19 2007
Citation
Jian Yang, Gregory W. Harrington, Daniel R. Noguera, Kala K. Fleming; Risk analysis of nitrification occurrence in pilot-scale chloraminated distribution systems. Journal of Water Supply: Research and Technology-Aqua 1 August 2007; 56 (5): 293–311. doi: https://doi.org/10.2166/aqua.2007.007
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00