A novel transient-based technique – the direct backward transient analysis (DBTA) – for leak location of single pressurized pipes is presented and tested using real-life data. A transient flow is generated in the pipe by closing the downstream end valve. The transient pressure signal is then measured only at the valve location. Using the method of characteristics and exploiting the measurements after full valve closure, the transient flow is backwardly analyzed by sweeping the pipe from the downstream to the upstream end. Knowing the upstream end heads, additional equations are developed to make the problem of leak detection determined and possible to be solved directly. A system of equations and unknown variables of leaks and flow specifications are then established and simultaneously solved together. Eventually, nodes with non-zero leak size are introduced as leaks. Finally, the method is applied to a real transmission pipeline, Lintrathen East Trunk Main Network at Scottish Water (Dundee, UK) and its abilities are investigated. The results show that the method is capable of dealing with real systems and is reliable, fast and easy to use.
Skip Nav Destination
Article navigation
May 2012
This article was originally published in
Journal of Water Supply: Research and Technology-Aqua
Article Contents
Research Article|
May 01 2012
Direct backward transient analysis for leak detection in pressurized pipelines: from theory to real application
Ali Haghighi;
1Department of Civil Engineering, Faculty of Engineering, Shahid Chamran University, Ahwaz, Iran
E-mail: [email protected]; [email protected]
Search for other works by this author on:
Didia Covas;
Didia Covas
2Department of Civil Engineering – Instituto Superior Técnico (IST), Technical University of Lisbon, Lisbon, Portugal
Search for other works by this author on:
Helena Ramos
Helena Ramos
2Department of Civil Engineering – Instituto Superior Técnico (IST), Technical University of Lisbon, Lisbon, Portugal
Search for other works by this author on:
Journal of Water Supply: Research and Technology-Aqua (2012) 61 (3): 189–200.
Article history
Received:
February 23 2011
Accepted:
March 09 2012
Citation
Ali Haghighi, Didia Covas, Helena Ramos; Direct backward transient analysis for leak detection in pressurized pipelines: from theory to real application. Journal of Water Supply: Research and Technology-Aqua 1 May 2012; 61 (3): 189–200. doi: https://doi.org/10.2166/aqua.2012.032
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00