Abstract
The focus of this work is on deriving the governing equations for the ‘shock damper’, an instrument used in water flow systems. The shock damper is a mechanical tool with a single degree of freedom system that includes a tank, connecting pipe, mass, spring and damper. This tool serves as a boundary condition for characteristic line equations. Additional equations are included by considering the conservation of mass, momentum and energy. This system of equations is then explicitly solved at each time step. In order to illustrate how the shock damper performs, two gravity feed systems with and without a damper are considered. In the first system, the control valve suddenly shuts, and in the second system, rapid demand change occurs in one of the nodes to impose a water hammer condition. Subsequently, unsteady flow parameters such as minimum/maximum flow velocity and pressure are evaluated and a sensitivity analysis is carried out. The results demonstrate that despite being simple and economically efficient, the shock damper is highly capable of moderating unsteady flow characteristics.
INTRODUCTION
One of the key factors to consider in designing a water distribution system is the effect of possible unsteady flow caused by a water hammer. A water hammer is a pressure surge or wave propagating at the speed of sound, which is created when a fluid (usually a liquid) in motion is forced to stop or change direction suddenly (momentum change). This phenomenon can occur for various reasons, including rapid valve opening and/or shutting, pump, joint or pipe failure, and using check valves. Water hammers cause intensive damage in some cases, making it a significant factor to keep in view while designing water distribution systems.
Two approaches to tackle this problem have been reported: (a) taking the necessary precautions to avoid a sudden change in flow velocity (or direction) that would cause a water hammer; and (b) equipping the water system with efficient tools to dampen the harmful impacts of a water hammer. As water hammers seem to be inevitable, the second approach is widely employed. Such tools (e.g., shock dampers) help depreciate the consequences of unsteady flow due to water hammers by compensating for any changes in flow pressure. Surge tanks and safety valves are the two kinds of water hammer damping equipment (Tijsseling 1996; Tijsseling et al. 1996). In order to simulate the dynamic behaviour of surge tanks, they are introduced as a boundary condition for characteristic line equations. Taking the conservation of mass, momentum and energy into account augments the number of equations in a system to n, where n is the number of unknown surge tank variables. Detailed discussions on this topic have been presented by Larock et al. (1999) and Skulovich et al. (2015, 2016). Safety valves are also applied as a boundary condition, and additional equations are derived to form a system of equations. Niełacny (2004) modelled spring safety valves in a water distribution system with pumps.
High operational cost is a major concern with utilizing surge tanks. Despite being expensive, one-way surge tanks are unable to dampen the positive pressure wave caused by a water hammer. They are only capable of preventing the negative waves and column separation by injecting flow to the pipeline (Larock et al. 1999; Chamani et al. 2013; Fathi-Moghadam et al. 2013). Air surge tanks can handle both positive and negative waves, but they are costly (Larock et al. 1999; Kim 2008, 2010). On the other hand, safety valves have much lower installation and maintenance costs, yet they perform poorly in restraining positive waves and are incapable of hindering negative waves; thus, column separation and consequent damage to the system are inevitable (Bergant & Simpson 1995; Ghidaoui et al. 2005). For this reason, we aim to find a simple and economic alternative for handling both negative and positive waves.
This study focuses on the shock damper in an attempt to derive its governing equations and illustrate its effectiveness. According to the results, shock dampers are highly capable of moderating unsteady flow characteristics. The rest of this paper is structured as follows. The next section defines the problem under study, which includes deriving and solving the equations for the given boundary conditions. Then the performance of the proposed approach is demonstrated by solving a case study. The results are depicted in the following section and the conclusions comprise the final section.
PROBLEM DEFINITION
The current study focuses on the proposed instrument, i.e., the shock damper. It is capable of encountering positive and negative waves caused by water hammers. In this section, the shock damper is demonstrated, the governing equation is derived, boundary conditions are considered and the resulting system of equations is solved.
Shock damper
A shock damper consists of a damper, spring, mass, tank and joint (Figure 1). The spring, damper and mass perform together as a vibrant system with a single degree of freedom (vertically) when positive or negative waves occur. The spring here is pre-pressed to capture sufficient force, which is used to balance the force caused by the pressure head. In the case of positive waves, the excessive pressure imposed on the spring compresses it further, storing potential energy. This potential energy protects the rest of the water distribution system from water hammer effects (waves). When a negative wave hits the shock damper, the pre-pressed spring elongates and water stored in the shock damper's tank is injected into the flow to compensate for the negative pressure. This helps prevent column separation and subsequent damage to the system. Theoretically, after a water hammer occurs, an infinite number of periodic waves must be created in the system. However, this is never the case as a result of friction and energy depreciation. The shock damper acts to accelerate the process of water hammer wave depreciation. Figure 1 illustrates a shock damper and its components, including the (1) damper, (2) spring, (3) mass, (4) joint and (5) tank.
Governing equations
Intermediate nodes


Boundary conditions
To derive the governing equations of a shock damper, a gravity feed system is considered. Such a system includes a pipe, tank, valve and shock damper, each with a specific equation (boundary condition).
Reservoir


Valve at node number i = Bv







Shock damper at node number i = Bsh



















Solving the system of equations for a shock damper




CASE STUDIES
The efficiency of the proposed model is examined against two benchmark examples from the literature. The examples are solved in two scenarios: with and without a shock damper. The aim is to demonstrate the effect of installing a shock damper on the flow characteristics of such systems.
First case study (rapid valve closure)
The example involves transients caused by rapid valve closure downstream of a long conduit with an upstream reservoir (solved by Saikia & Sarma (2006) and Afshar & Rohani (2008)). A water hammer condition is created by shutting the downstream valve at TC = 4 seconds. The initial system condition includes a constant flow rate in the pipe.
Scenario 1
In this case, the system is not equipped with a shock damper. The piezometric head in the tank is 600 ft; the main pipe diameter is 2 ft; the pipe length is 12,000 ft and the Darcy–Weisbach coefficient is f = 0.02 (for both steady and unsteady flow). The steady discharge is 12 ft3/sec, the pressure wave velocity after valve closure is a = 3,000 ft/sec and and
are assumed to be 3,000 ft and 1 sec, respectively.
Scenario 2
All other parameters are assumed similar to those in scenario 1.
Second case study (rapid demand change)
This example considers transients caused by rapid demand changes in one of the nodes (solved by Larock et al. 1999). This network is supplied by gravity flow from two elevated reservoirs. The pipe and node numbers are shown in Figure 4 with the pipe diameters and lengths. The pressure wave velocity in all pipes is a = 2,800 ft/sec, and are assumed to be 300 ft and 0.1 sec, respectively.
Scenario 1
In this case, the system is not equipped with a shock damper. Nodes 1 through 4 have ground elevations of 860 ft, while nodes 5 and 6 have ground elevations of 980 ft and 960 ft, respectively. The equivalent sand roughness of all pipes is e = 0.002 in. The demand increases from 450 to 900 gal/min at node 2 to meet the sudden need for more water for fire suppression. This effect indicates an increase in demand on the head of node 4.
Scenario 2
A shock damper is used in this scenario located 50 ft upstream of node 4. The parameters related to the shock damper are similar to those in the first case study, except the tank diameter here is Dr= 5 ft.
RESULTS AND DISCUSSION
As seen in Figures 5 and 6, a water hammer caused by sudden valve closure can generate piezometric heads (and corresponding pressure) of up to 1,200 ft and 100 ft when no shock damper is used. This is relatively severe pressure resulting in extensive damage to the system. Maximum pressure (positive values) can cause pipes to explode. Moreover, the next head peaks reach 1,100 ft and 150 ft due to friction in the pipeline and energy depreciation, although the resulting pressure is high. In this scenario, the impact of the water hammer is still visible after around 300 sec. When a shock damper is utilized as described in scenario 2, the maximum and minimum pressure heads calculated are 720 ft and 540 ft, respectively. This is a greater reduction (40% for the maximum and 80% for the minimum head) compared to scenario 1. Moreover, the peak heads significantly depreciate after almost 50 sec, reaching 650 ft and 550 ft. In the second case study and as indicated in Figure 7, the maximum and minimum pressure heads adjust from 260 ft and 0 ft, respectively, to 165 ft and 55 ft. After about 15 sec, the pressure oscillation also disappears due to the shock damper.
Pressure head vs time at valve node calculated by previous researchers and in the current work for result fitting (first case study – scenario 1).
Pressure head vs time at valve node calculated by previous researchers and in the current work for result fitting (first case study – scenario 1).
Pressure head vs time with shock damper at valve node (first case study – scenario 2).
Pressure head vs time with shock damper at valve node (first case study – scenario 2).
Pressure head vs time with and without shock damper at node 4 (second case study – scenarios 1 and 2).
Pressure head vs time with and without shock damper at node 4 (second case study – scenarios 1 and 2).
A sensitivity analysis of the system is described herein. The results indicate that shock damper performance is more sensitive to three parameters: main damping coefficient, tank diameter, and shock damper spring stiffness. Tables 1–3 summarize the sensitivity analysis outcome.
Maximum pressure change with damping coefficient (Dr= 10 ft and Ks = 1.4 × 107 lb/ft)
C (lb.s/ft) | 0.5 × 105 | 1.0 × 105 | 1.5 × 105 | 2.0 × 105 | 2.5 × 105 |
PMAX (ft) | 1,100 | 988 | 720 | 814 | 1,152 |
C (lb.s/ft) | 0.5 × 105 | 1.0 × 105 | 1.5 × 105 | 2.0 × 105 | 2.5 × 105 |
PMAX (ft) | 1,100 | 988 | 720 | 814 | 1,152 |
Maximum pressure change with tank diameter (C = 1.5 × 108 lb.sec/ft and Ks = 1.4 × 107 lb/sec)
Dr (ft) | 6 | 8 | 10 | 12 | 14 |
PMAX (ft) | 1,011 | 860 | 720 | 690 | 573 |
Dr (ft) | 6 | 8 | 10 | 12 | 14 |
PMAX (ft) | 1,011 | 860 | 720 | 690 | 573 |
Maximum pressure change with spring stiffness (Dr= 10 ft and C = 1.5 × 108 lb·sec/ft)
Ks (lb/ft) | 0.6 × 107 | 1.0 × 107 | 1.4 × 107 | 1.8 × 107 | 2.8 × 107 |
PMAX (ft) | 1,150 | 1,023 | 720 | 812 | 990 |
Ks (lb/ft) | 0.6 × 107 | 1.0 × 107 | 1.4 × 107 | 1.8 × 107 | 2.8 × 107 |
PMAX (ft) | 1,150 | 1,023 | 720 | 812 | 990 |
Table 1 shows the maximum pressure head obtained at the valve location for damping coefficients of +66% and −66% of its initial value. Evidently, an increase in the damping coefficient decreased the shock damper efficiency, hence a greater piezometric head was generated. Decreasing this parameter improved the shock damper's performance. However, a limitation is that further parameter reduction would deteriorate efficiency, suggesting the necessity to seek an optimal level. The system responses to main tank diameter changes are demonstrated in Table 2. As expected, the shock damper performed better with increasing tank size. However, there was a feasible upper limit to this expansion due to physical and economic constraints. Besides, beyond a certain level, any further increase in size appeared to have no considerable effect. Again, this implies there was an optimal level for this capacity expansion. In a situation where the diameter approaches zero, a system with a shock damper and main tank diameter of zero is expected to perform similarly to a system without a shock damper. Table 3 presents the maximum pressure head changes with spring stiffness. The table indicates that an increase and decrease from the optimum values increased the maximum head, so there were optimum values at which the maximum heads could be minimum.
CONCLUSION
Water hammers in water distribution systems are inevitable. Due to the extensive damage caused by this phenomenon, its impact on a system must be moderated efficiently. A shock damper is a simple and economically efficient piece of equipment that can be used to handle devastating consequences such as pipe explosions. The present study concentrated on deriving the governing equation of a shock damper and using it to model the system. Results demonstrated that installing a shock damper in a gravity-feed system can effectively dampen the pressure waves caused by a water hammer. A sensitivity analysis revealed that shock damper performance is mostly dependent on the main tank diameter and the shock damper's damping coefficient. This study also suggests obtaining optimal parameter values in order to maximize performance.