Skip to Main Content

Low Phosphorus Analytical Measurement Study

By
Lazaro Eleuterio
Lazaro Eleuterio
HDR, Inc 2365 Iron Point Road, Suite 300 Folsom, CA 95630, Email: lazaro.eleuterio@hdrinc.com
Search for other works by this author on:
JB Neethling
JB Neethling
Senior Vice President, HDR, Inc 2365 Iron Point Road, Suite 300 Folsom, CA 95630, Phone: (916) 817-4830; Cell: (916) 801-9043; Fax: (916) 817-4747; Email: jb.neethling@hdrinc.com
Search for other works by this author on:
IWA Publishing
Volume
8
ISBN electronic:
9781843392873
Publication date:
September 2009

Phosphorus measurements at very low concentrations have been tested and proven to be unreliable. The establishment of stricter phosphorus discharge requirements has challenged the wastewater facilities to be capable of measuring low phosphorus concentrations (20 μg/L) in the effluent. The major challenge associated with low phosphorus measurements seems to be related to the sample matrix and the digestion methodologies. The results of total phosphorus measurements in wastewater effluent, high quality deionized water samples, and orthophosphate measurements in wastewater effluent samples show a broad variability. In contrast, the orthophosphate measurements in the deionized water matrix spiked to 3 μg/L and 6 μg/L show an insignificant variability. The Ascorbic Acid Method seems to be a reliable technique to measure orthophosphate at low levels. The findings of the current study have demonstrated that as the phosphorus concentration increases, the variability decreases. A good reliable analytical process is needed to provide information to regulators for setting sound permit limits and by utilities required to meet those limits. Current methods show significant variability at very low (<20 μg/L) concentrations when measuring total phosphorus and orthophosphate.

This study provides important information regarding the capability of wastewater and commercial laboratories to determine low phosphorus concentration (0-20 μg/L) accurately. The findings of this study raises some important questions regarding establishing permit limits and the ability of utilities to comply with the limits. Measurements to comply with very low limits (<20 μg/L TP) will inherently vary, making it impossible to determine both the environmental impact of the discharge stream and the performance of the utility.

This title belongs to WERF Research Report Series.

ISBN: 9781843392873 (eBook)

Low Phosphorus Analytical Measurement Study
By: Lazaro Eleuterio, JB Neethling
DOI: https://doi.org/10.2166/9781843392873
ISBN (electronic): 9781843392873
Publisher: IWA Publishing
Published: 2009

Download citation file:


×
This content is PDF only. Please click on the PDF icon to access.
Close Modal
This Feature Is Available To Subscribers Only

Sign In or Create an Account

Close Modal
Close Modal