Skip to Main Content

Sewer Lateral Electro Scan Field Verification Pilot

By
Jerome Flogel
Jerome Flogel
Search for other works by this author on:
Andrew Lukas
Andrew Lukas
Search for other works by this author on:
IWA Publishing
Volume
12
ISBN electronic:
9781780405063
Publication date:
September 2013

This research effort evaluated an innovative sewer lateral condition assessment tool in unique testing conditions, providing an opportunity for comparison to other traditional assessment approaches. This study field tested over 100 sanitary sewer lateral pipes for potential infiltration-generating defects using the Electro Scan ES-38TM technology according to ASTM F2550-006. Results of these inspections were compared to the results of other infiltration data produced in rainfall simulation tests of the same laterals and water exfiltration tests of each scanned pipe. The Electro Scan ES-38TM measurements were also compared to closed-circuit television (CCTV) inspection of laterals according to NASSCO Pipeline Assessment Certification Program (PACP) standards. Statistical comparisons of Electro Scan ES-38TM assessments to estimated leakage rates, from a field rainfall simulation test, were performed to determine the best means of correlating the two data sets.

The research effort was used to test the Electro Scan approach against the dye water/rainfall simulation testing techniques that the City of Wauwatosa (Wauwatosa) has already used to derive convincing condition information in general and on specific properties within the proposed testing area. Prior to this research effort, Electro Scan technology had only been tested side-by-side against CCTV inspection information.

The objectives of this proposed research effort were as follows:

Test Electro Scan ES-38TM in the two pilot lateral rehabilitation project areas;

  1. Compare Electro Scan ES-38TM results to pre-rehabilitation condition dye water/rainfall simulation tests;

  2. Compare Electro Scan ES-38TM results to CCTV inspection results;

  3. Perform water exfiltration tests and compare results to Electro Scan ES-38TM results;

  4. Evaluate the feasibility of performing Electro Scan ES-38TM tests from basement cleanouts; and

  5. Establish pros and cons of Electro Scan ES-38TM lateral condition evaluations, including estimated costs.

This title belongs to WERF Research Report Series.

ISBN: 9781780405063 (eBook)

Sewer Lateral Electro Scan Field Verification Pilot
By: Jerome Flogel, Andrew Lukas
DOI: https://doi.org/10.2166/9781780405063
ISBN (electronic): 9781780405063
Publisher: IWA Publishing
Published: 2013

Download citation file:


×
This content is PDF only. Please click on the PDF icon to access.
Close Modal
This Feature Is Available To Subscribers Only

Sign In or Create an Account

Close Modal
Close Modal