Over the past two decades, techniques have been developed for pipeline leak detection and condition assessment using hydraulic transient waves (i.e. water hammer waves). A common measurement strategy for applications involves analysis of signals from a single pressure sensor located at each measurement site. The measured pressure trace from a single sensor is a superposition of reflections coming from upstream, and downstream, of the sensor. This superposition brings complexities for signal processing applications for fault detection analysis. This paper presents a wave separation algorithm, accounting for transmission dynamics, which enables the extraction of directional travelling waves by using two closely placed pressure sensors at one measurement site (referred to as a dual-sensor). Two typical transient incident pressure waves, a pulse wave and a step wave, are investigated in numerical simulations and laboratory experiments. Comparison of the wave separation results with their predicted counterparts shows the wave separation algorithm is successful. The results also show that the proposed wave separation technique facilitates transient-based pipeline condition assessment.
INTRODUCTION
The aging of water distribution systems worldwide has brought many issues, ranging from significant water and energy losses (Colombo & Karney 2002) to risks to public health due to possible pathogen intrusion (Karim et al. 2003). Over the past two decades, hydraulic transients (water hammer waves) have been identified as a useful tool for non-invasive pipeline leak detection (Mpesha et al. 2001; Ferrante & Brunone 2003; Covas et al. 2005; Lee et al. 2005; Soares et al. 2011; Ferrante et al. 2013; Duan 2016), blockage detection (Sattar et al. 2008; Meniconi et al. 2013; Massari et al. 2014), wall condition assessment (Gong et al. 2013; Stephens et al. 2013) and general system parameter identification (Zecchin et al. 2013, 2014a). When undertaking a hydraulic transient analysis of a pipeline system, a transient disturbance (a pulse or a step pressure wave) is typically introduced by abruptly operating a valve. Then the transient pressure wave propagates along the pipe in both upstream and downstream directions. Any physical changes or anomalies in a pipeline will affect the propagation of transient pressure waves, resulting in specific reflections. These reflections can be analysed in either the time or frequency domain, in order to diagnose the anomalies in the pipeline system.
Most existing studies are based on the analysis of the transient pressure measured by a single sensor, or by multiple sensors usually separated by a significant distance along pipes. However, there are often simultaneous waves travelling in opposite directions. The hydraulic pressure at any single point in a pipeline can be expressed as the sum of a travelling pressure wave coming from upstream of the measurement point and a travelling pressure wave coming from downstream. As a consequence, for a single pressure sensor, the measured signal is always a superimposed signal of waveforms propagating upstream and downstream. One measurement strategy to avoid a superposition problem is by placing the measurement point at a dead end to ensure the reflection comes only from one direction (Gong et al. 2014). However, when investigating transmission mains, which may be tens of kilometres long, it is not always practical to find an ideal measurement point at a dead end. Moreover, when multiple anomalies exist on both sides of a sensor, which is the common case in most pipelines, the measured pressure signal can be very complex and difficult to interpret, even when multiple measurement sites are used (Gong et al. 2016a).
To investigate and extract the directional information of travelling transient pressure waves, Gong et al. (2012a) proposed a technique that uses two pressure sensors (100 m spaced in a pipe with an internal diameter 600 mm) to separate the pressure waves travelling downstream from those travelling upstream along a pipeline. In a subsequent study by Gong et al. (2012b), a new measurement strategy, which involved the use of two pressure sensors in close proximity (1 m spaced in a pipe with an internal diameter 600 mm), was proposed to facilitate the wave separation. However, these preliminary studies were limited to numerical simulations with ideal conditions where the pipeline between two sensors is assumed to be lossless and the incident wave is a sharp step signal.
Zecchin et al. (2014b) proposed a technique for extracting the impulse response of a single pipeline using a pair of sensors (10 m spaced in a pipe with an internal diameter of 200 mm) for measurement, and using hydraulic noise as the excitation. The hydraulic noise is in the form of wide-sense stationary pressure signals (the mean function and correlation function do not change over time). In that study, a theoretical propagation loss between two sensors was considered. However, the directional travelling waves were not extracted from the measurements. The wide-sense stationary pressure signals are difficult to achieve in practice, and only a numerical case study was conducted in that paper.
It should be noted that the use of two pressure sensors in close proximity (referred to as a ‘dual-sensor’ in the following) for wave separation has been studied in the acoustics research area, where acoustic waves in ducts measured by two (or more) microphones are analysed (Chung & Blaser 1980). However, hydraulic transient waves in water-filled pipes have many differences from acoustic waves propagating in the air, namely, they have a different signal bandwidth, wave magnitude and wave propagation properties where wall friction plays a much more significant role. Moreover, the research in acoustic ducts focuses on calculating the reflection and transmission coefficients, rather than splitting the directional travelling waves explicitly, which is the focus of the wave separation method developed in the current paper. In the field of pipeline transient analysis, the use of two pressure sensors in close proximity has been used for unsteady flow measurement (Washio et al. 1996; Kashima et al. 2013). However, except for the preliminary numerical work reported in Gong et al. (2012a, 2012b) and Zecchin et al. (2014b), to the knowledge of the authors, there is no study on the separation of hydraulic transient waves using a dual-sensor in pressurised pipelines.
The research reported in the current paper develops a systematic wave separation algorithm that can extract the two directional travelling hydraulic transient waves from pressure traces as measured by two closely spaced pressure sensors. Compared to the preliminary numerical work in Gong et al. (2012a, 2012b) and Zecchin et al. (2014b), the new developments include: (1) an experimental data-driven approach to estimate the transfer function between the two sensors, which enables wave separation without the knowledge of the specific pipe parameters (e.g. flow rate, friction factor, and diameter of the pipe); (2) the extraction and removal of the incident waves, making the algorithm applicable to real incident waves with curved wave fronts rather than the theoretical sharp incident waves used in previous studies; and (3) the first experimental verification of the wave separation technique.
To validate the wave separation algorithm, a pulse incident wave is used in a numerical study and a step wave is considered in a laboratory study. In both studies, as presented in this paper, the comparison between the extracted directional reflection trace with its counterpart, which has a reflection from one direction only, shows the wave separation algorithm is successful. The wave separation algorithm provides the directional information of travelling transient pressure waves in pipelines and simplifies the interpretation of the signals. The directional waves, as obtained in the laboratory study, are then used to determine the properties of two deteriorated pipe sections in the experimental system (simulated by short pipe sections with thinner wall thicknesses). The results demonstrate that the proposed wave separation technique can adequately facilitate transient-based pipeline condition assessment. Limitations of the technique and practical challenges are discussed before drawing the conclusions.
WAVE SEPARATION ALGORITHM USING A DUAL-SENSOR
Hydraulic wave propagation theory
Determination of the transfer function H(s)
Analytic representation
From a practical perspective, using the analytic form (11), H(s) can be completely specified using measured values of l, a, and a calibrated value of R (or known D with estimates of and f).
Experimental representation
As an alternative to the analytic expression for H(s), the properties of the transfer function can also be determined experimentally. In hydraulic transient analysis, a pipeline system is typically excited by abruptly opening or closing a valve, which results in a discrete wave with a short duration as an incident pressure wave (e.g. a sharp step or pulse wave). Under these conditions, an assumption can be made that during the time of the incident wave entering into the system at T1 then exiting the system at T2, there are no transient waves entering the system from T2 (i.e. in Figure 1). This assumption is often valid when the incident wave is short, and the system is excited from a steady state condition. Therefore, the LTI system in Figure 1(a) can be temporarily treated as a single-input and single-output system for this short time period. The input is the incident wave at T1, and the output is the incident wave at T2. The incident waves and can be extracted from the original measured pressure trace and by applying a rectangular time window (i.e. truncating the short signal section that includes the wave front out of the whole pressure trace).
The wave separation algorithm
In Figure 1(a), when an incident pressure wave is generated at G and arrives at sensor T1, the positive travelling pressure wave at T1 contains the incident wave and the reflected wave coming from upstream of T1. The reflected wave is the focus because it carries the pipeline information that can be used for pipeline condition assessment. However, compared to the incident wave, the reflections due to wall deterioration are usually small (Gong et al. 2015). Given this, removing the dependence of the incident wave from the wave separation results leads to clearer separated directional travelling waves, and the method is described below.
The inverse Laplace transforms of Equations (21) and (22) will give the positive travelling reflected waves and the negative travelling reflected waves in the time domain.
For analysis of real pipeline systems where the pressure signals measured by sensors are used, the value of the Laplace variable is restricted to the imaginary axis, i.e. , where i is the imaginary unit and is the radial frequency. Consequently, the Fourier transform can be used instead of the Laplace transform.
To apply the wave separation algorithm to pressure traces [ and ] measured by a dual-sensor as in Figure 1(a), the following steps will be performed:
- 1.
Time-windowing to separate incident waves and reflections in the original pressure traces measured by a dual-sensor using Equations (19) and (20).
- 2.
Transfer incident waves and reflections into the frequency domain by using the Fourier transform.
- 3.
Determine the transfer function between two sensors using the analytic Equation (11) or using the experimental Equation (14).
- 4.
Extract the directional reflection waves in the frequency domain using Equations (21) and (22).
- 5.
Transfer wave separation results into the time domain using an Inverse Fourier Transform, or using the results directly in the frequency domain for further analysis, e.g. determine the frequency response of the pipe section.
It should be noted that, when other incident waves are used in place of discrete waves with a short duration, Step 1 can be ignored and Equations (9) and (10) in Step 4 used instead. Before the wave separation algorithm is applied to real data, pre-processing may be needed, including determining the effective frequency range to minimise the impact of high frequency noise on the time domain reconstruction of the separated reflected waves. Because the analysis is built on linear systems theory, the incident waves should be small perturbations to limit the effect of linearization (Lee & Vítkovský 2010).
NUMERICAL VERIFICATION
To verify the dual-sensor wave separation algorithm, numerical simulations have been conducted. A single pulse hydraulic pressure wave is used as the incident wave in the numerical investigations since it has never been studied previously for wave separation.
System layout and procedure
Link . | Length (m) . | Internal diameter (mm) . | Wall thickness (mm) . | Wave speed (m/s) . | Friction factor (–) . |
---|---|---|---|---|---|
L1 | 415.9593 | 500 | 8 | 1,154 | 0.017 |
L2 | 12.0213 | 504 | 6 | 1,083 | 0.030 |
L3 | 72.0096 | 500 | 8 | 1,154 | 0.017 |
L4 | 0.9809 | 500 | 8 | 1,154 | 0.017 |
L5 | 0.9809 | 500 | 8 | 1,154 | 0.017 |
L6 | 69.9901 | 500 | 8 | 1,154 | 0.017 |
L7 | 150.1451 | 500 | 7 | 1,123 | 0.017 |
L8 | 60.0080 | 500 | 8 | 1,154 | 0.017 |
L9 | 11.9944 | 506 | 5 | 1,036 | 0.030 |
L10 | 205.9890 | 500 | 8 | 1,154 | 0.017 |
Link . | Length (m) . | Internal diameter (mm) . | Wall thickness (mm) . | Wave speed (m/s) . | Friction factor (–) . |
---|---|---|---|---|---|
L1 | 415.9593 | 500 | 8 | 1,154 | 0.017 |
L2 | 12.0213 | 504 | 6 | 1,083 | 0.030 |
L3 | 72.0096 | 500 | 8 | 1,154 | 0.017 |
L4 | 0.9809 | 500 | 8 | 1,154 | 0.017 |
L5 | 0.9809 | 500 | 8 | 1,154 | 0.017 |
L6 | 69.9901 | 500 | 8 | 1,154 | 0.017 |
L7 | 150.1451 | 500 | 7 | 1,123 | 0.017 |
L8 | 60.0080 | 500 | 8 | 1,154 | 0.017 |
L9 | 11.9944 | 506 | 5 | 1,036 | 0.030 |
L10 | 205.9890 | 500 | 8 | 1,154 | 0.017 |
An incident pressure wave is generated at time t = 0.1 s by manoeuvring the side-discharge valve. The incident wave is a pulse wave with 20 ms duration, generated by fully closing the side discharge valve then fully opening it again (the manoeuvre is designed numerically that the incident pulse pressure wave as generated has a shape similar to a cosine function changing from to , to make the signal more realistic than a sharp instantaneous rise). The response of the pipeline system is simulated by MOC with steady friction only.
Wave separation results
For a comprehensive comparison, the wave separation results are compared with predicted results as computed directly from the MOC. The predicted results for upstream reflections ( as shown in Figure 4(a)) are obtained from MOC modelling the system similar to that depicted in Figure 2, but only with one deteriorated section L2 existing on the upstream side of the sensors. On the downstream side of the sensors, there are just uniform intact pipes (i.e. L7 and L9 are set as the same as the intact sections). Hence, the simulated reflections only come from upstream and are a result of section L2. Similarly, the predicted results for downstream reflections ( as shown in Figure 4(b)) are acquired by MOC modelling with no defective sections existing on the upstream side of the sensors, so reflections only occur on the downstream side of the sensors and include reflections from sections L7 and L9.
It can be seen in Figure 4 that the reflections from the three thinner-walled pipe sections are separated and clearly shown in the directional waves and respectively. The separation results from two different transfer function calculation methods (analytical and experimental) are almost identical, and both of them have an excellent match with the MOC predictions. It should be noted that the separated results of directional waves include multiple reflections while the predicted results do not. The multiple reflections are due to secondary reflections between anomalous sections on the two sides of sensors. For example, when all three thinner-walled sections are considered in the simulation, the major wave reflections from sections L7 and L9 (as shown in Figure 4(b)) will propagate from downstream to upstream, pass the dual-sensor and then be reflected by section L2 as secondary reflections. These secondary reflections will then propagate downstream as part of . Nevertheless, the numerical simulation demonstrates that the proposed wave separation approach is valid for pipelines excited by single pulse incident pressure waves.
EXPERIMENTAL VERIFICATION
Laboratory experiments have been conducted in a single copper pipeline in the Robin Hydraulics Laboratory at the University of Adelaide. The laboratory system is a copper pipe (internal diameter 22.14 mm, total length 37.43 m) bounded by two pressurised tanks. The pressurised tanks can be isolated by an in-line valve to make the system a reservoir-pipeline-valve (R-P-V) configuration. A step incident pressure wave is used to avoid repetition from the numerical study and it better represents the incident waves used in the field.
System layout and procedure
Pipe class . | Internal diameter (symbol = value (mm)) . | Wall thickness (symbol = value (mm)) . | Wave speed (symbol = value (m/s)) . |
---|---|---|---|
A | D0 = 22.14 | e0 = 1.63 | a0 = 1,319 |
B | D1 = 22.96 | e1 = 1.22 | a1 = 1,273 |
C | D2 = 23.58 | e2 = 0.91 | a2 = 1,217 |
Pipe class . | Internal diameter (symbol = value (mm)) . | Wall thickness (symbol = value (mm)) . | Wave speed (symbol = value (m/s)) . |
---|---|---|---|
A | D0 = 22.14 | e0 = 1.63 | a0 = 1,319 |
B | D1 = 22.96 | e1 = 1.22 | a1 = 1,273 |
C | D2 = 23.58 | e2 = 0.91 | a2 = 1,217 |
The majority of the pipeline is in Class A. Two short pipe sections of Class B and C, respectively, which have thinner wall thicknesses than that of Class A, are placed in the system to simulate pipe sections with wall deterioration. The head in the pressurised tank was controlled at approximately 31 m during the experiments. The in-line valve at the other end was kept closed during the experiments.
A solenoid side-discharge valve was used as the transient generator (G) and placed at the same location as pressure sensor T1. The other pressure sensor (T2) was located upstream (on the left) of the transient generator separated by a distance of 0.99 m. A step pressure wave was generated by abruptly closing the solenoid valve in approximately 3 ms. The pressure responses were measured by the two sensors with a sampling frequency of 20 kHz.
Wave separation results
Application to pipeline condition assessment
It is obvious that the original pressure measurements as shown in Figure 9 cannot be directly used for condition assessment because the reflections from the Class B and the Class C sections are superimposed. In contrast, the separated directional wave reflections as shown in Figure 8 show the wave reflections from the two sections separately and clearly, and they can easily be used for further analysis.
The values of the relative wave reflections from the Class C and Class B sections are determined from the minima of and respectively as shown in Figure 8, for which the results are and respectively. The magnitude of the incident step wave is determined as from the measured trace shown in Figure 6(b). As a result, the normalized reflections for the Class C and Class B sections are and , respectively. Referring to the look-up chart in Figure 10, the relative change in wall thickness corresponding to these two wave reflections are and , respectively. Finally, using the wall thickness of the Class A pipe of e0 = 1.63 mm, the wall thicknesses in the Class C and Class B sections are determined by the reflection analysis as and , respectively. Compared with the wall thicknesses as given by the manufacturer ( and as shown in Table 2), the wall thicknesses are estimated with relatively high accuracy.
These results have demonstrated that the wave separation algorithm as developed in this research can significantly facilitate pipeline condition assessment by resolving the complexity due to wave superposition.
DISCUSSION
Some practical issues related to real applications of transient-based pipeline condition assessment are discussed in this section. Recommended future work is also presented.
Detection resolution
The spatial resolution of detection is limited by the effective bandwidth of the pressure waves, which is itself related to the sharpness of the wave front. For a ramp incident wave, theoretically one can accurately diagnose deteriorated sections only with a length longer than , where is the rise time of the ramp wave front and is the wave speed in the deteriorated pipe section (Gong et al. 2013). Sections shorter than that may still be detectable but will not give a full-sized reflection, therefore the change in wall thickness will be underestimated. In the experimental study, the rise time of the incident step was about 3 ms. Using a wave speed of 1,300 m/s, the threshold is calculated as approximately 2 m.
Detection range
The length of pipe that can be assessed reliably mainly depends on the signal-to-noise ratio (SNR). It is expected that measurements in the field can have stronger noise than in the laboratory (e.g. due to pump operations). The frequency range to include in the analysis should be selected carefully to balance the SNR and detection resolution (as discussed above). Usually low frequency waves have better SNR than high frequency components, because the latter typically have less initial energy and suffer higher damping rates. A spectrum analysis for the wave reflections (as described in the Experimental verification section) will help to determine the useful bandwidth. Nevertheless, field trials by the authors confirmed that a step transient pressure wave can travel many kilometres with insignificant attenuation in water transmission mains (diameter 600 mm) (Stephens et al. 2013; Gong et al. 2015, 2016a). However, the sharpness of the wave front decreases over the distance of propagation.
Non-uniform deterioration
In real pipelines, deteriorated sections most likely have non-uniform wall thickness variations. As a result, the wave reflections may not have sharp edges as shown in the laboratory study. In such cases, the extrema of the reflections should be used to calculate the normalized head perturbation. The determined wall thickness represents the general condition of the deteriorated section.
Other sources of reflections
In addition to deteriorated pipe sections, wave reflections can be induced by other sources, which typically include changes in pipe material and class, leaks, blocks, branches and air pockets. Priori information of pipeline systems (e.g. as constructed drawings) will be helpful in identifying the source of wave reflections. The characteristics of the wave form can also facilitate the categorisation (e.g. discrete blocks introduce extended positive reflections while leaks introduce extended negative reflections). Note that pipe joints typically do not introduce noticeable reflections, since the dimension of joints is much smaller than the effective wavelength.
Accuracy of transfer function
A topic for future work is to enhance the accuracy in the determination of the transfer function between the two pressure sensors. Error in the transfer function will affect the wave separation and therefore the condition assessment. It can be induced by background noise and the inconsistency among pressure transducers (i.e. for the same pressure condition, different sensors may give slightly different readings). The use of sensor arrays to provide redundant information may be helpful in enhancing the accuracy.
CONCLUSIONS
A wave separation algorithm has been developed for extracting the directional hydraulic transient pressure waves that travel along a pipeline in the downstream and upstream directions, respectively. Discrete incident transient waves, such as a single pulse or a step wave which are commonly used in transient-based pipeline fault detection, are used to excite a pipeline system and induce reflections from deteriorated pipe sections. The wave separation is achieved by analysing the pressure responses of the pipeline as measured by a proximity dual-sensor setup. The wave separation resolves the complexity of the superposition of travelling pressure waves in a pipeline, providing directional information of wave reflections and simplifying the wave forms. The key contributions of the research include: (1) the development of an experimental technique for estimating the transfer function between two sensors that is more practical than analytical estimation for real pipelines with parameter uncertainties; (2) the further development of the wave separation algorithm to enhance the accuracy for the separation of the relatively small wave reflections by removing the dependence of the relatively large incident wave; and (3) the verification of the wave separation technique by numerical and laboratory experiments.
In the numerical simulations, a discrete pulse pressure wave is considered as the incident wave, which has not been studied previously for hydraulic transient wave separation in pipelines. Three thinner-walled pipe sections are placed in the numerical pipeline system, with two of them simulating deteriorated sections due to internal corrosion and one simulating a section with a lower pipe class. The wave separation algorithm has been successfully implemented, with the resultant directional reflection waves consistent with the predicted results.
Experimental verification of the hydraulic transient wave separation algorithm has been conducted. A step transient pressure wave generated by a fast closure of a side-discharge valve is considered as the incident wave. The original pressure responses as measured by the dual-sensor spaced at 0.99 m include the superimposed wave reflections from two thinner-walled pipe sections. The directional reflection waves are extracted by the wave separation algorithm and the results are generally consistent with the numerically generated predicted results. An existing pipeline condition assessment technique that is based on direct time domain analysis of wave reflections is adopted and applied to the extracted directional waves. The wall thicknesses of the two thinner-walled pipe sections are estimated from the reflected waves by using the pipe wall thickness change look-up chart and the results are consistent with the specifications provided by the manufacturer. The experimental study has validated the proposed wave separation algorithm, and confirmed the usefulness of the algorithm in transient-based pipeline condition assessment and fault detection.
ACKNOWLEDGEMENTS
The research presented in this paper has been supported by the Australia Research Council through the Discovery Project Grant DP140100994 and the Linkage Project Grant LP130100567.