Abstract
The present study proposes a new interactive methodology and an interactive tool for the response to water network failure events facilitating near real-time decision-making. The proposed methodology considers: (i) a structured yet flexible approach supporting and guiding the operator throughout the entire response process to water network failure events, while allowing the operator to have a final say; (ii) a novel interaction with the operator in near real time via the proposed tool (e.g. allowing operators to propose different ‘what-if’ scenarios without being hydraulic experts); (iii) the provision of automatically generated advice (e.g. optimal response solutions and assessed end-impacts) – although optimal response solutions not identified in near real time yet; and (iv) improved impact assessment using realistic impact indicators that cover different aspects of the event – which are consistently calculated for every proposed response solution (to facilitate easy comparison between different response solutions). The new methodology was applied on a semi-real case study. The results obtained demonstrated the potential of the new response methodology and its application through the interactive tool to improve water utilities' current practice. This was accomplished through supporting/guiding operators in the identification of effective response solutions with low end-impact on the consumers and low cost for the utility.
HIGHLIGHTS
Novel structured overall response methodology supporting operators throughout the whole response process.
Improved impact assessment.
Realistic selection of operational interventions (based on operational costs, the availability of different types of interventions, etc.).
Novel near real-time interaction with the control room operator (manual ‘what-if’ scenarios and automatic optimal solutions).
INTRODUCTION
The water industry in the UK and worldwide faces considerable challenges in making effective use of sensor and other data that are collected in water distribution systems (WDSs) in near real time (typically every 15–30 mins). These data are still not used much in a water utility's control room, especially when it comes to identifying a suitable strategy to respond to failure events in near real time, i.e. events such as major pipe bursts, equipment failure or water treatment work (WTW) shutdowns. Relevant academic work has not adequately addressed this challenge mainly due to the focus on specific stages (i.e. isolation, impact assessment or intervention) rather than the overall response process. Furthermore, for an effective near real-time response, there is still a need to develop: (1) improved impact assessment methods that are based on realistic metrics used in the water industry and that are also used in a consistent manner to facilitate easy comparison between different response solutions (i.e. a response intervention or a set of interventions), (2) more realistic selection of response interventions to be implemented (e.g. based on operational costs, the availability of different types of interventions, etc.) and (3) effective interaction with the control room operators that takes into account their expert judgement, preferences and experience.
In this study, a novel response methodology that aims to fulfil the above needs is proposed. The new response methodology is implemented via an interactive decision-support tool entitled the Interactive Response Planning Tool (IRPT). The IRPT is used to guide/support operators in identifying an effective response solution in near real time (i.e. usually required up to 1 h after the event detection/localisation). The main aim of this study is to show the potential of the IRPT to improve utilities' current practice by supporting/guiding operators in the identification of low end-impact (i.e. the total impact after the implementation of the response solution) and low-cost response solutions.
This paper is organised as follows. Firstly, background information relevant for the present study is presented. Subsequently, the new response methodology (including its concept, details of the indicators used in the impact assessment and information regarding the optimisation of the response interventions) is described. Later, results from a semi-real case study are presented and discussed. Finally, conclusions from the application of the new methodology and of the interactive tool are drawn.
BACKGROUND
An ‘event’ is denoted here as any failure that has a negative impact on a WDS's performance in terms of the water utility's temporary inability to deliver a regular service. An efficient event management process in WDSs can be divided into three principal stages: event detection, event localisation and event response (Vamvakeridou-Lyroudia et al. 2010; Romano et al. 2011; Jung et al. 2015; Kapelan et al. 2017). The first two stages involve detecting and localising the event in the network and raising the relevant alarm. The third stage is associated with the decisions and actions required to reduce and, ultimately, eliminate the negative impact of the event on the consumers (Jeong et al. 2006; Bicik et al. 2009; Nayak & Turnquist 2016). The first two stages have been researched extensively in the literature (Bicik et al. 2011; Romano et al. 2011; Casillas Ponce et al. 2014; Romano et al. 2014; Jung et al. 2015; Okeya et al. 2015; Laucelli et al. 2016; Romano 2019; Zhou et al. 2019). Hence, the focus of this paper is on the event response stage.
The event response stage typically includes two sub-stages, namely isolation and recovery (Vamvakeridou-Lyroudia et al. 2010, Mahmoud et al. 2018). The isolation sub-stage aims to minimise the negative initial impact of an event and prepare the affected part of the network for follow-on repairs. This sub-stage has been thoroughly studied in the past by several authors such as Jun & Loganathan (2007) and Giustolisi & Savic (2010). Hence, it is not the subject of the present work. The recovery sub-stage, on the other hand, involves impact assessment of the event and selection of the best response solution. This sub-stage is the focus of this study.
Several methods for event impact assessment, such as Kapelan et al. (2006), Kao & Li (2007), Giustolisi et al. (2008), Bicik et al. (2009) and Qi et al. (2018), have been proposed in the literature. These methods are all based on rather theoretical impact assessment metrics. This aspect is, therefore, further investigated in this work by developing and using a wider range of improved impact assessment metrics that are based on real-life indicators used by water utilities.
The selection of the best response solution to implement is strongly dependent on the preceding steps of the event management process. An effective event management process should be based on an integrated methodology that takes into account all the preceding stages. However, in the literature, the recovery sub-stage has been approached mainly through (1) proposing theoretical mitigating methods for the minimisation of the consequences of a physical attack (e.g. Jeong et al. 2006; Jeong & Abraham 2009; Turner et al. 2012) and (2) proposing generic decision-support systems (DSSs). For example, Bicik et al. (2008) proposed a general risk-based DSS methodology for supporting operators in decision-making against a failure. Vamvakeridou-Lyroudia et al. (2010) proposed an integrated Intervention Management Model, in the context of a general DSS methodology for operational WDS management. Finally, Mahmoud et al. (2018) proposed an integrated methodology for the near real-time response to pipe burst events in WDSs. All these methods, however, are rather academic in nature as they do not take into account the complexities of real-world response problems. This aspect is accounted for in this work by making use of the control room operators' extensive knowledge and experience via their interaction with the IRPT.
Paez et al. (2020), in their summary paper, presented several methods for the response to WDS events after an earthquake disaster (i.e. they considered real-life and complex pipe network failures). Later, Zhang et al. (2020) proposed an optimisation-based framework to maximise resilience of a WDS after a disaster-type event (e.g. earthquake). However, both these studies identified the optimum set of response interventions that includes pipe repair or replacement only (i.e. without proposing different types of response interventions). This limitation is circumvented in this work by developing a methodology that utilises multiple intervention types (e.g. rezoning, water injection) and that also enables identifying the best time for their implementation in the field in order to restore supply.
RESPONSE METHODOLOGY
Current practice response methodology
Different utilities deal with events in a different way and use more or less structured approaches. This section briefly describes a response methodology mainly based on ad hoc response interventions that can be considered typical for the UK water sector. In this methodology, the response interventions are largely based on the experience and expert judgement of control room operators, despite various systems being used by the operators to support their decisions.
The detection of an event in a water utility is nowadays usually done in two possible ways: (a) through customer calls (i.e. reporting no water/low pressure/discolouration, etc.) and/or (b) through an automated detection system (i.e. alarms generated based on flow and/or pressure data). Once the detected event is confirmed and approximately localised (e.g. roughly based on customer calls' addresses and/or using other semi-automated means), the utility typically mobilises some available water trucks, called Alternative Supply Vehicles (ASVs). This is done as an immediate restoration measure after an initial impact assessment usually carried out manually and/or with limited hydraulic model support. Here, an assessment involving the calculation of the water volume required to be supplied per hour (and hence the number of ASVs required per hour) based on the affected district metered areas (DMAs) normal water demand may also be carried out. At the same time, in the control room, after further manual (e.g. by checking service reservoirs' levels using online systems) and/or hydraulic model-supported initial impact assessment, operators request isolation of the event. Isolation is then carried out either as soon as possible (e.g. if the service reservoirs' levels are quickly dropping or there is significant third-party damage) or later in the day, depending on severity/time of the event and other factors. There are also occasions where the repair can be conducted without isolating the failure (i.e. under pressure). If isolation is required, the isolation valves are usually identified manually – as the closest operable valves to the event. With some ASVs already on site (or not), the control room operators then attempt to identify the most suitable response solution (e.g. how many more ASVs should be sent to the site, a suitable rezoning plan, overland bypasses, etc.) to be implemented while the repair is being carried out. Online map systems, offline connectivity maps, calculation sheets and hydraulic models can be used by the operators for this purpose.
Bearing in mind the above, it is worth stressing that despite using hydraulic models for some of the aforementioned activities can be considered as common practice, hydraulic analysis is not always carried out thoroughly due to limitations in terms of the time that can be dedicated to this activity, the skills required to run hydraulic simulations, the ability to only test a few scenarios and the difficulty to consistently assess their end-impact.
New response methodology
The concept
The new response methodology proposed in this paper consists of the following main steps: Step (1) initial impact assessment, Step (2) identification of the isolation plan, Step (3) manual identification of a response solution proposed by an operator, Step (4) automatic identification of a response solution generated using optimisation and Step (5) identification of the response solution to be implemented in the field. Note that these five steps do not need to be necessarily carried out in a sequential manner as presented here.
The implementation of the new methodology within the IRPT is conducted through the following three-stage routine in each step: Stage (1) involves obtaining the operators' inputs, Stage (2) involves carrying out hydraulic simulations to assess the end-impact/cost for each solution and Stage (3) involves visualising the calculated end-impact of each solution. The new response methodology's steps are described in more detail in the remainder of this section and are also shown as a flowchart in Figure 1.
Step 1. Following the confirmation (i.e. detection and localisation) of an event, an initial impact assessment is performed assuming the ‘do nothing’ scenario. At this point, the operators are asked if isolation needs to take place or if it can be carried out.
- a.
If yes, the operators create an event isolation plan in Step 2.
- b.
If no, they move to Step 3 to propose a manual solution.
Step 2. For the identification of the isolation plan, the best (i.e. closest to the event) set of valves is automatically provided to the operators by the IRPT and the operators are then asked if they are satisfied with this set (e.g. if the identified valves can been localised and are operable). If they are not satisfied, they ask the IRPT to automatically provide the next best set of isolation valves. As soon as the best set of isolation valves is selected, the operators input into the IRPT the isolation duration and different potential isolation start times. Then, the IRPT automatically calculates the end-impact of the different isolation start times, and these are presented to the operators. In view of the calculated end-impacts, the operators can then select a desired start time of isolation. Once the isolation plan is finalised, the operators are asked if they consider the resulting end-impact low.
- a.
If yes, they proceed with the implementation of the ‘isolation only’ final solution without applying any further intervention. The operators then move to Step 6.
- b.
If no (or isolation is not possible), they then identify the more comprehensive response solution as follows. The operators are asked if they want the IRPT to automatically generate an optimal solution.
- i.
If yes, they move to Step 4.
- ii.
If no, they proceed by proposing a manual solution in Step 3.
- i.
Step 3. In this step, the operators are able to propose a manual solution by interacting with the IRPT. Here, the IRPT firstly enables the operators to input their desired and available (e.g. accessible/operable rezoning valves) intervention(s) and the start time of this (these) intervention(s). It then provides decision support to the operators by assessing and visualising the end-impact/cost of the proposed manual solution. Then the operators are asked if they are satisfied with the end-impact/cost of their proposed manual solution.
- a.
If yes, a final solution has been found and the operators move to Step 6.
- b.
If no, the operators are allowed to propose alternative manual solutions and compare their end-impact/cost by moving to Step 5 or ask the IRPT to automatically generate an optimal solution in Step 4.
Step 4. Operators input into the IRPT all the desired and available interventions, as well as a time range in which the various interventions could start. Then, the optimisation runs and optimal solutions are automatically generated and assessed by the IRPT. Operators are then able to select one (or more) optimal solution(s) on the Pareto front (depending on whether or not the end-impact/cost is low). Finally, they are asked if they wish to further modify this (these) solution(s) manually.
- a.
If yes, they move to Step 5.
- b.
If no, a final solution has been found and they move to Step 6.
Step 5. In this step, the operators are first asked if they want to go back all the way to Step 1, with the modified system state used as a starting point. This is done to account for the fact that the situation may have changed in the meantime. If not, they can further modify a solution from Step 3 or Step 4, as well as proposing new solution. Here, the IRPT enables operators to compare all of the identified solutions consistently (i.e. consistent impact metrics) and with support of effective visualisations (e.g. multiple maps in a single window) of the end-impacts and costs. All this enables the operators to select the final solution they wish to implement.
Step 6. Once the system operation is back to normal, the operators identify the lessons learned.
In the IRPT, the hydraulic simulations are carried out by using EPANET2 (Rossman 2000) and pressure-driven network modelling based on methodology developed by Paez et al. (2018). The demand-driven analysis conducted by EPANET2 accurately estimates the nodal demands in normal operating conditions but not in the pressure-deficient ones that occur during various system failures (e.g. during a pipe burst or some equipment failure). Hence, in this study, the original EPANET2 hydraulic model is modified by using the approach proposed by Paez et al. (2018). This method works by adding suitably chosen dummy elements to the original EPANET2 model. This creates the pressure-driven model that is able to simulate hydraulic conditions in the network under both normal- and pressure-deficient conditions. Paez et al.’s pressure-driven method has been selected here as it was thoroughly tested, validated and demonstrated to work effectively on real-sized networks producing accurate hydraulic results (Paez et al. 2018). The use of this model provides additional computational burden for the calculation of different impact indicators but then so does any other pressure-driven method – this is simply the price to pay for being able to simulate pressure-driven conditions in the pipe network. Finally, note that the selection of a pressure-driven model is not the focus of this study, i.e. any other reliable and accurate pressure-driven model can be used instead within the response methodology presented in this paper.
The IRPT also links to the Quantum Geographic Information System (QGIS) software to visualise the spatial distribution of end-impact on a suitable map of the analysed water system.
The key novelties of the new response methodology proposed are as follows: (i) structured yet flexible approach supporting and guiding the operator throughout the entire response process (from detection and localisation of a failure event to the implementation of the identified response solution in the field) while allowing the operator to have a final say, (ii) novel interaction with the operator in near real time (i.e. up to 1 h) via the IRPT (e.g. ‘what-if’ scenarios) without hydraulic expertise requirements, (iii) provision of automatically generated advices (e.g. optimal response interventions and assessed impacts) – although the optimal response interventions are not yet provided in near real time due to the long (e.g. several hours) optimisation time currently required (longer than the time typically available in a control room for identifying a response), (iv) improved impact assessment (based on realistic impact indicators) that covers different aspects of the event – which are consistently calculated for every proposed response intervention (to facilitate easy comparison between different response solutions) and (v) more realistic selection of operational interventions (based on operational costs, the availability of different types of interventions, etc.).
Impact assessment
The IRPT provides to operators the capability to automatically assess the end-impact of a proposed solution (i.e. in Stage 2 of each step of methodology) based on realistic metrics. In the IRPT, a consistent framework for end-impact assessment (i.e. same impact metrics calculated for every proposed response solution) is implemented. This facilitates the comparison of different response solutions (in Step 5 of the methodology) and enables more informed decision-making. Furthermore, the IRPT allows the operators to perform this comparison without the need for them to be hydraulic model experts.
The impact indicators proposed in this paper have been developed bearing in mind the UK water industry practice as well as previous relevant literature (e.g. Bicik et al. 2009). Most of these indicators have not been used before in this context (at least in the published literature). The following aspects of end-impact are considered here: water supply interruption, low pressure impact and discolouration risk increase (DRI) impact. More specifically, the following indicators are used: (1) customer minutes lost (CML), (2) average minutes low pressure (AMLP), (3) unaccounted for water (UW) and (4) DRI. AMLP and UW are calculated for different customer types, namely residential, industrial and sensitive (i.e. schools and hospitals). The impact horizon in the new response methodology is the period of time for which the end-impact is assessed. It starts from the detection/localisation time of an event and lasts until the repair is completed (i.e. time period over which restoration interventions can be implemented).
The DRI is estimated based on a combination of the methods found in Beuken et al. (2008) and Bicik et al. (2009). Beuken et al. (2008) suggest to calculate discolouration risk based on minimum and maximum velocities and maximum flow rates. Here, the minimum and maximum flow velocities in an average demand day are calculated with a hydraulic model for each pipe. The same model is used to estimate the largest flow rate for each pipe under the same demand conditions. Then, a score is assigned to each pipe for each discolouration risk type (i.e. based on velocities and on flow rates). Hence, a score of 1 means low, a score of 2 means moderate and a score of 3 means high discolouration risk. The discolouration risk for every pipe is calculated as the sum of the scores based on both velocity and flow rate. The resulting discolouration risk scores are grouped in five severity categories (Beuken et al. 2008), i.e. ‘VERY LOW’ with a total score of 2, ‘LOW’ with a total score of 3, ‘MODERATE’ with a total score of 4, ‘HIGH’ with a total score of 5 and ‘VERY HIGH’ with a total score of 6.
Once the discolouration risk score for every pipe has been found, the DRI for every pipe can be calculated as the difference between the discolouration risk score under ‘failure’ and normal conditions. The ‘failure’ condition is defined here as the WDS condition after the occurrence of the event and/or the implementation of the intervention(s). The DRI is then ranked based on the total score increase, i.e. ‘NO RISK’ with a total score increase equal to 0, ‘LOW INCREASE’ with a total score increase equal to 1, ‘MODERATE INCREASE’ with a total score increase equal to 2 or 3 and ‘HIGH INCREASE’ with a total score increase equal to 4.
Interventions optimisation
The IRPT provides to operators the capability to automatically identify a number of optimal solutions (i.e. in Step 4 of the methodology) by solving a two-objective optimisation problem. The two objectives are the minimisation of total end-impact (of a response solution) and the minimisation of the total cost associated with this solution.
The decision variables of the optimisation problem are (1) the operational interventions used and (2) the start times of their implementation. The operational interventions considered in this methodology are (1) rezoning by valve manipulations (i.e. opening of initially closed boundary valves), (2) water injection at different network locations and (3) combination of these. Water injection, which is a novel type of intervention considered in this study, is carried out through the ASVs. In this study, an ASV is modelled as a tank linked to the injection point through a pump (to manage the pressure pumped into the network) and a valve (to allow water flow from the tank to the system). Usually, utilities dispatch three ASVs of 30 m3 to every injection point in order to guarantee continuous supply to the affected node/customers. In this study, to simplify the coding required in the IRPT, one artificial ASV with volume equal to 90 m3 (i.e. 3 × 30 m3) is modelled at each injection point.
It is important to highlight here that apart from the type of interventions, the start time of each intervention is a decision variable too. Likewise, it is important to stress that rezoning is assumed to last until the repair is complete (i.e. as in utility's general practice) and, hence, its duration is not considered as a decision variable. ASV injection, on the other hand, is carried out until the tank (modelled at each injection point, see above) gets empty. This may happen before the repair is complete, depending on the water demand (under normal conditions) of the affected area.
In view of the above, each identified optimal solution takes the form of an action plan, as it was also done in Sophocleous et al. (2018). The Non-Dominated Sorting Genetic Algorithm II or NSGA II (Deb et al. 2002) is used in this paper to solve the optimisation problem. This method has already been proved to be appropriate for solving a similar optimisation problem (Mahmoud et al. 2018). The mathematical description of the present multi-objective problem, as well as the optimisation constraints considered in this study, can be found in the Supplementary Material.
It is stressed here that optimising for minimum end-impact and cost has multiple benefits for a utility. The most important benefit is reducing the impact on the customers which can be costly in many ways (financially but also in terms of reputation, etc.). A couple of other examples related to costs include: (1) operational savings in the long term as many events may occur each year – although the cost of a single response solution may be small (e.g. hundreds of pounds) and (2) less time spent on site for opening valves or injecting water – this could benefit utilities in terms of more efficient scheduling of the technicians' activities.
CASE STUDY
The present case study aims to illustrate the benefit of a response solution identified through interaction with the IRPT (hereafter referred to as the ‘New methodology response’) by comparing it to a response solution based on utilities' current practice (hereafter referred to as the ‘Current practice response’). For this purpose, a semi-real case study (described hereunder) was considered. Then, the IRPT's steps are implemented for the case study's event in order to identify the ‘New methodology response’. The ‘New methodology response’ is ultimately compared with the ‘Current practice response’, in order to demonstrate the benefit resulting from the operator's interaction with the IRPT.
Description of the semi-real case study
The case study used here is based on the following real system and event. On Saturday 2nd November 2019 at 14:00, a WTW that serves approximately 100,000 customers located in the North West of England shut down following observation of high turbidity levels. This event was due to a burst on a main within the WTW. The shutdown resulted in intermittent supply and low pressure to some customers. The WTW remained shut until the quality of the water leaving the WTW could be assured to meet the required standards. The utility mobilised ASVs to the area and implemented network changes (i.e. rezoning) in order to minimise customer end-impact. Bottled water was delivered directly to priority services and sensitive customers. The repair was completed 24 h after the shutdown.
In the IRPT, the shutdown is modelled by closing the pipe downstream the service reservoir directly fed by the WTW (the WTW feeds this service reservoir only), in order to facilitate the hydraulic simulations. As far as the actual utility's response actions are concerned, a number of simplifications and assumptions were made to simplify the coding required in the IRPT. For example, ASV injection at each point is carried out by using a single artificial ASV (equivalent to the 3 × 30 m3 ASVs usually sent to every injection point). However, in reality ASVs supplied water intermittently at some injection points (i.e. started at different times during the event and did not inject water consecutively) and with more than three ASVs used in some cases. Additionally, the rezoning valves considered in the IRPT's simulations do not necessarily coincide with the rezoning valves actually used by the utility during the event. This is due to the fact that the hydraulic model used did not precisely reflect the real valves' layout. Finally, the actual start times of the interventions have been rounded to the next hour (e.g. if an intervention started at 19:30 in real-life, then in the IRPT it assumed to start at 20:00).
Because of all of the above, we refer to the case study under scrutiny as ‘semi-real’ (i.e. based on a real system and event, but with several simplifications and assumptions). Bearing in mind the typical response strategy described earlier, we refer to the response actions shown in Table 1 as the ‘Current practice response’ although they only approximate (i.e. in terms of total end-impact, start time of impact, affected areas, etc.) the actual real-life response. This said, it is also important to stress here that many factors may have influenced the actual response actions taken by the utility. These factors have not been accounted for in this study and, hence, the term ‘Current practice response’ should be construed accordingly.
Saturday Nov 2nd 2019 | |
14:00 | WTW shut down |
20:00 | ASV injection in DMA 009 (one injection point) |
21:00 | ASV injection in DMA 004 (one injection point) |
22:00 | ASV injection in DMA 010 (one injection point) |
Sunday Nov 3rd 2019 | |
00:00 | Rezoning from DMA 001 to DMA 005 (five rezoning valves) |
00:00 | Rezoning from DMA 005 to DMA 006 (five rezoning valves) |
01:00 | ASV injection in DMA 007 (two injection points) |
09:00 | ASV injection in DMA 003 (one injection point) |
09:00 | Rezoning from DMA 003 to DMA 008 (two rezoning valves) |
14:00 | Repair is completed |
Saturday Nov 2nd 2019 | |
14:00 | WTW shut down |
20:00 | ASV injection in DMA 009 (one injection point) |
21:00 | ASV injection in DMA 004 (one injection point) |
22:00 | ASV injection in DMA 010 (one injection point) |
Sunday Nov 3rd 2019 | |
00:00 | Rezoning from DMA 001 to DMA 005 (five rezoning valves) |
00:00 | Rezoning from DMA 005 to DMA 006 (five rezoning valves) |
01:00 | ASV injection in DMA 007 (two injection points) |
09:00 | ASV injection in DMA 003 (one injection point) |
09:00 | Rezoning from DMA 003 to DMA 008 (two rezoning valves) |
14:00 | Repair is completed |
New methodology response
In this section, the identification of the response solution through the IRPT's steps is presented. It is worth stressing at this point that Step 2 of the IRPT methodology is not applied here because the event is considered to be the shutdown (i.e. not the burst). Hence, in this case, operators do not need to ask the support of the IRPT for the identification of the best isolation start time and of the best isolation valves to close.
Initial impact assessment (methodology Step 1)
The first step of the methodology is to apply the initial impact assessment. Here, operators aim at assessing the initial end-impact over the impact horizon (i.e. until the repair is completed). Therefore, for the purposes of this work, they input into the IRPT the repair completion time as 24 h. This is because, despite the fact that the completion time can only roughly be estimated before the actual repair commences, 24 h is considered to be a reasonable period over which the repair of a major burst is likely to be carried out. Figure 2(a) shows the location of the considered service reservoir and the downstream pipe that was closed (i.e. pipe P8703) for modelling the shutdown, as well as the location of the industrial users, schools, hospital and the network model's DMAs (each DMA represented with different colouration).
The values of the four impact indicators, for the initial condition of the system (denoted hereafter as ‘No response’), are calculated in the IRPT. Considering that the total number of customers registered in the utility is equal to 3,293,080 (value obtained by the utility), Pmin is equal to 3 m and Preq is equal to 15 m (as applied in water utilities' practice), then CML is equal to 4.0 mins/cust, AMLP is equal to 3.6 mins/cust, UW is equal to 3,330 m3 and DRI is equal to 14 pipes (out of the 8,950 pipes in this section of network). This results in a total initial end-impact as equal to 11.1%. The location of the affected customers with supply interruption (SI) for more than 3 h is shown in Figure 5(a) (with purple-gradient colouration), in sets of 3 h (i.e. 3–6, 6–9, 9–12, >12 h). The above impact values (computed over the 24-h impact horizon) highlight the significance of this event that affected a wide area comprising different DMAs. The affected area also includes two schools and one industrial node and the hospital (all purple-gradient coloured depending on the SI duration). However, the risk of discolouration (or DRI) could be considered low (i.e. only 14 pipes are at high risk).
Using the IRPT, operators are also able to check the pressure over the impact horizon and, hence, get a view of when the aforementioned affected customers start getting end-impact. At the bottom of Figure 5(a), the pressure graph for DMA 005 (selected as an example here because the hospital is located in that DMA) is presented. It can be noticed that DMA 005 (and, hence, the hospital too) starts being affected approximately 5 h after the shutdown, if nothing is done. The IRPT also provides the capability to visualise the other aspects of the impact, such as the low pressure duration at each node, the volume of undelivered water at each node and the DRI at each pipe, as well as for different DMAs, in a similar way as shown in Figure 5(a). All this is a significant advantage over what done/available as part of current practices. This step takes approximately 3 mins to be completed on the PC used in this study (Intel processor, Core i5-6200U CPU at 2.30 GHz and 64-bit Windows 7), i.e. as long as a single impact evaluation takes for the present complex network.
Manually proposed solution (methodology Step 3)
For the purposes of this work, a fictional operator proposes a realistic (i.e. that could have potentially be identified in the utility's control room) manual solution (denoted hereafter as ‘New response – manual’) in Step 3 of the methodology, after having carried out the initial end-impact assessment. The available interventions are shown in Figure 2(b). Looking at the initial end-impact (in Figure 5(a)), the fictional operator decides to inject water into the affected DMAs 003, 004, 010 and 007 and rezone-affected DMAs 005, 006 and 008 by opening all the available rezoning valves. This is because the fictional operator wants to intervene into all affected DMAs where available interventions exist. Then, looking at the pressure graphs of the DMAs where ASV injection is available (i.e. DMAs 003, 004, 010 and 007), presented in Figure 3 for the ‘No response’ scenario, he/she decides to start injecting into these DMAs 5 h after the shutdown (i.e. when the impact starts in the horizon). This is because he/she wants to allow plenty of time to mobilise the ASVs and also allow injection to start at 19:00 when a peak in demand is expected. He/she finally decides to rezone as soon as possible (here assuming 2 h after the shutdown to allow plenty of time for technicians to get to site), because rezoning for longer periods is expected to significantly reduce end-impact without increasing cost (i.e. rezoning duration does not affect cost, see Equation (7)). Bearing in mind the above, it is worth stressing that the IRPT supports operators with modelling different ‘what-if’ scenarios in an easy way. For example, the same fictional operator could have also tried opening fewer valves to rezone those DMAs just by modifying the information he/she did input in one field of the IRPT's graphical user interface.
Assuming that crez is equal to £27, cASV is equal to £32 (both provided by the utility to make this manual solution more realistic) and drez = 2 h (i.e. 1 h for technicians to open one rezoning valve and another 1 h to close it), then CML is equal to 1.2 mins/cust, AMLP equal to 1.7 mins/cust, UW equal to 1,235 m3 and DRI is equal to 316 pipes in the network. The total end-impact is equal to 4.5% and the cost is equal to £813. The location of the affected customers with SI of more than 3 h and the pressure graph of DMA 005 after applying the ‘New response – manual’ solution are shown in Figure 5(b). This step takes approximately 3 mins to be completed on the PC used in this study, i.e. as long as a single impact/cost evaluation of one manual solution takes for the present complex network.
Optimal solution (methodology Step 4)
After having assessed the end-impact/cost of their manually proposed solution in Step 3, the fictional operator asks the support of the optimisation in Step 4. Details of the assumptions/simplifications applied in the optimisation carried out here are as follows: (1) each rezoning valve can open at different times in the horizon in the range of 1 h (i.e. the earliest time rezoning can usually start) and 23 h (i.e. the latest time rezoning can start in the present 24-h hydraulic simulation) after the shutdown, (2) injection at each ASV point can start at a different time in the range of 1 h (i.e. the earliest time injection can usually start) and 23 h (i.e. the latest time rezoning can start in the present 24-h hydraulic simulation) after the shutdown (the time ranges in points 1 and 2 can be easily modified by the operators) and (3) the operators decide to give priority to reducing CML and UW as in utilities' practice these indicators are usually considered important. Despite its importance, it was chosen not to give higher priority to DRI in this optimisation problem, because minimisation of the second objective (i.e. cost) is expected to substantially reduce the risk of discolouration (due to minimisation of the number of valve manipulations and ASV injections). Based on the above, the following indicator weights are used (see Equation (5)): wCML = 0.4, wAMLP = 0.15, wUW = 0.3 and wDRI = 0.15. These are indicative weight factors selected here to illustrate the desired priority, but can be easily changed in the IRPT by the decision-maker.
For the calculation of the total end-impact, the maximum values of the impact indicators (i.e. for normalisation, see Equation (6)) are calculated as follows. For the CML and AMLP, the total number of customers in the section of network under scrutiny is equal to 46,545, and the simulation duration is equal to 24 h = 1,440 mins. The maximum value of UW is equal to the total volume of water required to supply the whole section of network under normal operation (equal to 175,530 m3). The maximum value of DRI is equal to the total number of pipes in the section of network (equal to 8,750 pipes). Hence, CMLmax = 20.35 mins/cust, AMLPmax = 20.35 mins/cust, UWmax = 175,530 m3 and DRI = 8,750 pipes. The minimum values of all impact indicators are equal to 0.
In the present optimisation problem, the number of decision variables is equal to 36 (i.e. 18 time variables and 18 valve status manipulation variables). The population size was set to 15 and the number of maximum generations to 100 (although 45 generations were required for the identification of the final Pareto front). In Figure 4, the NSGA II Pareto front of optimal solutions (i.e. black colour), the ‘New response – manual’ solution (blue colour) and the ‘No response’ case (i.e. yellow colour) are presented. The present optimisation problem was completed in a couple of days, i.e. not in real time. This is considered as a drawback of the present methodology, which is addressed here by developing a heuristic-based optimisation methodology (i.e. this will be presented in future work as the focus of this paper is the new response methodology).
Identification of the final response plan (methodology Step 5)
After the optimisation (Step 4 of the methodology) is completed, in Step 5, the fictional operator decides to compare the identified optimal solutions with the ‘New response – manual’ solution in order to identify the best response plan. Here, for illustration reasons, he/she selects one solution from the Pareto front in order to compare it with the ‘New response – manual’ solution. The selected optimal solution (denoted hereafter as ‘New response – optimal’, pointed with a black arrow in Figure 4) is a solution with significantly reduced end-impact for a small cost increase compared with the rest of the optimal solutions with less cost and bigger impact (i.e. solutions found at the left side of the selected one) on the Pareto front. Such a solution is quite likely to be selected by a decision-maker.
The values of the impact indicators of the ‘New response – optimal’ solution (as well as those of the ‘New response – manual’ and ‘No response’) are shown in Table 2. As can be seen from this table, the values of CML and UW are significantly reduced in the ‘New response – optimal’ compared with the ‘No response’ case. This implies that the considered weight factors were effective in this problem. It is also observed that the ‘New response – manual’ solution obtains smaller impact values for the CML, AMLP and UW compared with the ‘New response – optimal’ solution. However, cost and DRI are significantly reduced in the ‘New response – optimal’ solution compared with the ‘New response – manual’ solution due to the optimisation enforcing cost minimisation. As expected, minimisation of cost function has also reduced the number of rezoning valves to open and the injection time, resulting in reduced disturbance in pipe flows, and consequently reduced risk of discolouration.
. | CML (mins/cust) . | AMLP (mins/cust) . | UW (m3) . | DRI (–) . | Cost (£) . | Total end-impact (%) . |
---|---|---|---|---|---|---|
No response | 4 | 3.6 | 3,330 | 14 | 0 | 11.1 |
Current practice response | 2.1 | 2 | 1,825 | 273 | 894 | 6.5 |
New response – manual | 1.2 | 1.7 | 1,235 | 316 | 813 | 4.5 |
New response – optimal (or New methodology response) | 1.6 | 2 | 1,475 | 92 | 55 | 5 |
. | CML (mins/cust) . | AMLP (mins/cust) . | UW (m3) . | DRI (–) . | Cost (£) . | Total end-impact (%) . |
---|---|---|---|---|---|---|
No response | 4 | 3.6 | 3,330 | 14 | 0 | 11.1 |
Current practice response | 2.1 | 2 | 1,825 | 273 | 894 | 6.5 |
New response – manual | 1.2 | 1.7 | 1,235 | 316 | 813 | 4.5 |
New response – optimal (or New methodology response) | 1.6 | 2 | 1,475 | 92 | 55 | 5 |
The ‘New response – optimal’ solution also suggests only one intervention, i.e. opening one rezoning valve which feeds DMA 005, starting 2 h after shutdown. No injection from ASVs is suggested, which explains the minimised cost (i.e. £55) of this solution. The significantly reduced total end-impact of the ‘New response – optimal’ solution (i.e. 5%), compared with the 11.1% of ‘No response’, is a consequence of starting the rezoning very early in the simulation (although only one valve is opened). It is also observed that the total end-impact of the ‘New response – manual’ solution (i.e. 4.5%) is not significantly lower than the total end-impact of the ‘New response – optimal’ solution (i.e. 5%). However, the cost of the ‘New response – optimal’ solution (i.e. £55) is much lower than the cost of the ‘New response – manual’ solution (i.e. £813).
Furthermore, Figure 5(c) shows that in the ‘New response – optimal’ solution, the number of affected customers with SI has been reduced when compared with the ‘No response’. However, in the ‘New response – manual’ solution, the affected area is smaller than the affected area in the ‘New response – optimal’ solution (e.g. DMA 011 is not affected with CML when applying the ‘New response – manual’ solution, but there is CML impact when applying the ‘New response – optimal’ solution). In both solutions, the hospital is not affected anymore (see also the pressure graphs in Figure 5(b) and 5(c)) when compared with the ‘No response’ case. If applying the ‘New response – manual’ solution, the initially (i.e. ‘No response’) affected schools (in DMAs 011 and 013) and the industrial node (in DMA 011) are not affected anymore. However, in the ‘New response – optimal’ solution, the school in DMA 011 is still affected, although for fewer hours (i.e. between 3 and 6 h) compared with the ‘No response’ case. Through Figure 5(b) and 5(c) operators are also informed that DMA 007 still has high SI impact (i.e. almost the whole DMA is affected with SI >12 h, although the total CML is low) in both ‘New response – manual’ and ‘New response – optimal’ solutions. It is reminded at this point that the only available intervention in DMA 007 is injection from two ASV points (see Figure 2(b)). Hence, the IRPT also serves the purpose of informing the operators that they should look into more available ASV points and/or available rezoning (e.g. from adjacent unaffected DMA 002) in DMA 007.
At this point in time (i.e. in Step 5 of methodology), based on the information obtained by using the IRPT, the fictional operator has to make the following decision: (1) apply the ‘New response – manual’ solution due to the reduced CML, AMLP and UW when compared with the ‘No response’, (2) apply the ‘New response – optimal’ solution where CML, AMLP and UW are also reduced when compared with the ‘No response’ (although higher than those in the ‘New response – manual’ solution) but with cost and DRI impact much lower than the cost and DRI impact of the ‘New response – manual’ solution, (3) test/assess a different manual solution (i.e. ‘what-if’ scenario) and compare it with the other identified solutions or (4) select a different optimal solution from the Pareto front in Figure 4 and compare it with the other identified solutions. For the purpose of this work, the different ‘what-if’ scenarios and the different optimal solutions are discounted due to space limitation. Hence, based on the results obtained, it is assumed that the fictional operator is more likely to select the ‘New response – optimal’ solution because of the minimum DRI (and small cost), as well as relatively low values of all the other impact indicators. The ‘New response – optimal’ solution is therefore considered to be the ‘New methodology response’ in the remainder of this paper. This step can be completed in a number of minutes in a water utility control room, when a limited number of comparisons takes place. In this case study, operators carried out a single comparison between the ‘New response – manual’ and the ‘New response – optimal’; hence, it is assumed that this step was completed in approximately 5 mins (as an example). From the above, it is shown that the whole response methodology can be implemented within 1 h, required for the near real-time response decision-making.
Comparison between ‘Current practice response’ and ‘New methodology response’
In Table 2, CML, AMLP, UW, DRI, cost and total end-impact calculated by the IRPT for the ‘Current practice response’ described in Table 1 are shown. It can be noticed that even though CML, AMLP and UW are reduced when compared with the ‘No response’ scenario, the ‘New methodology response’ (i.e. the ‘New response – optimal’ solution) offers further improvements. Indeed, the ‘New methodology response’ further reduced all impact indicators (especially DRI and cost), except AMLP which remained the same. The ‘New methodology response’ also suggested fewer interventions to implement (i.e. opening of only one rezoning valve compared with opening of 12 valves and injecting from 5 points in the ‘Current practice response’), justifying the significant improvement in DRI and cost.
In light of the above, it can be concluded that the ‘New methodology response’ identified through interaction with the IRPT outperforms the ‘Current practice response’.
CONCLUSIONS
This paper presents a novel overall response methodology that aims to support/guide water utility operators in making better informed decisions regarding water network failures. The new response methodology considers (1) improved impact assessment methods (based on realistic metrics used in the water industry), (2) consistent impact assessment (i.e. impact metrics consistently calculated for every response solution to facilitate easy comparison), (3) provision of automatically generated advices (e.g. optimal response interventions and assessed end-impacts), (4) more realistic selection of operational interventions (based on operational costs, the availability of different types of interventions, etc.) and (5) novel near real-time (i.e. identification of a solution within 1 h after event detection/localisation) interaction with the control room operator that takes into account their expert judgement/experience (e.g. proposing ‘what-if’ scenarios) without hydraulic model expertise requirements. The new methodology is implemented via an interactive decision-support tool aiming to support operators in making better informed decisions.
The application of the new methodology on a semi-real case study showed that the tool enabled operators to identify a more effective response solution (i.e. reduced end-impact and cost) compared with the ‘Current practice response’. This is because the tool allowed operators to compare alternative response strategies (i.e. manually created by the operator and automatically generated by the IRPT through optimisation). This comparison was facilitated by the consistent impact assessment (i.e. same metrics assessed for each solution) used in the tool, as well as by the comprehensible impact metrics (i.e. well-known metrics in utilities), impact coverage (shown in maps) and cost of different solutions (shown in graphs). Hence, this application showed the potential of the IRPT to be used by utilities to make better and more informed decisions. All the methodology's steps apart from the optimisation step can currently be conducted in near real time (i.e. to identify a solution within 1 h after event detection/localisation).
Future work on further improvement of the proposed methodology and tool will focus on: (1) the improvement of the DRI index (e.g. to take into account the flow direction into the pipe network, as well as the pipe material), (2) the improvement of ASV injection modelling (i.e. injection in one point at different times in the day should be modelled) and (3) the improvement of the optimisation methodology in order to identify optimum solutions faster (i.e. in near real time). The latter point is of crucial importance to effectively enable optimal solutions to be used in the near real-time response framework presented in this paper.
ACKNOWLEDGEMENTS
This work was funded as part of the Water Informatics Science and Engineering Centre for Doctoral Training (WISE CDT) under a grant from the Engineering and Physical Sciences Research Council (EPSRC) (grant no. EP/L016214/1), as well as from United Utilities. The present work has made use of resources, data and information provided by United Utilities.