Water is the main stimulus for the development of microorganisms, and its flow has an important role in the spreading of contaminants. In hospitals, the water distribution system requires special attention since it can be a source of pathogens, including those in the form of biofilms often correlated with resistance of microorganisms to various treatments. In this paper, information relevant to cases of nosocomial infections involving water circuits as a source of contaminants is compiled, with emphasis on the importance of microbiological control strategies to prevent the installation, spreading and growth of microorganisms in hospitals. An overview of the worldwide situation is provided, with emphasis on Brazilian hospitals. Different approaches normally used to control the occurrence of nosocomial infections due to waterborne contaminants are analyzed, and the use of the polysaccharide chitosan for this specific application is briefly discussed.

A hospital infection can be defined as any infection acquired after patient admission and manifested during hospitalization or after patient release, being then related to hospitalization or hospital procedures. A hospital infection can be also defined as a localized or systemic condition resulting from an adverse reaction to the presence of an infectious agent(s) or its toxin(s) that was not present on admission to the acute care facility. Commonly used synonyms of hospital infection include the terms nosocomial or healthcare-associated infection (HAI).

The transmission of microorganisms responsible for nosocomial infections is a serious and recurrent public health problem, affecting both developing and developed countries. As an example, in the USA around 2 million healthcare-associated infections occur yearly, causing approximately 90,000 deaths and costing close to $4.5 billion in excess healthcare (Ecker & Carroll 2005). While the average rate of hospital infection in the USA and Europe is 10%, in Brazil it is around 15% (ANVISA 2004).

The control of hospital infections in Brazil has been regulated since 1982 by the Ministry of Health; however, only in 1997 was a Federal law (number 9431) formally established to compel hospitals to maintain a program of preventive and corrective actions related to the spreading of pathogens. Around 45,000 deaths are recorded yearly as a result of infections acquired in hospitals in Brazil, from a total of 12 million hospitalizations. General hospital infections are, unfortunately, the leading cause of deaths in intensive care units (ICUs) in Brazil, and waterborne-related contaminations play a significant role in this scenario. As a result of general nosocomial infections, the length of stay of a patient in a hospital can be extended by 10 to 14 days on average, generating costs of around $5 billion annually in complementary treatments (APM 2006).

Organisms related to nosocomial infections are very diverse, being detected both in suspension and bound to surfaces in contact with water, in the form of biofilms. The source of microbial dissemination depends on many environmental factors, which can be minimized by specific control programs involving critical materials (surfaces, equipments and others) to prevent the occurrence of high contamination levels. Regular programs include periodical microbiological counts, visual inspection, and regular disinfection procedures, in accordance with the regulatory practice in force.

Wet surfaces and water storage and distribution systems are major sources of potentially pathogenic microorganisms that are not easy to detect or to control. The so-called waterborne pathogens include different types of bacteria, mycobacteria, fungi, parasites, and viruses (Anaissie et al. 2002a). Microbial biofilms, in particular, may be responsible for more than 65% of bacterial infections in the USA (Potera 1999), and this estimation was more recently increased to 80% by the National Institutes of Health of the same country (Lebeaux et al. 2013).

Microorganisms can easily adhere to piping systems and regions that accumulate water, especially those in which the water flow is difficult, forming biofilms. Relevant factors in the reduction of the overall quality of water and which favor the development of biofilms include the number and position of stagnant points in the water supply system, corrosion, and aging of the distribution system itself (pipe lines, connections, and storage tanks), as well as the formation of solid deposits on their surfaces. The contaminants may not only be transported by the running water system, but they may also be spread by the aerosol formed in taps and showers, dissipating easily in the environment. Surfaces conditioned by spills of contaminated water facilitate the deposition of other molecules and pathogens, and are prominent among the areas most favorable to microbial growth in hospitals.

As a result, the exposure of a patient to waterborne pathogens in a hospital may occur in many different situations, such as during a shower or a bath, while drinking water, due to the use of medical equipment rinsed with contaminated water, or to manipulation by medical personnel whose hands were previously washed with contaminated tap water (Shareef & Mimi 2008).

Biofilm-related infections are characterized by their chronicity and high resistance to antibiotics (Hanke et al. 2013), which makes microbiological diagnosis difficult and generally worsens a hospitalized patient's condition. In fact, in the worst scenario, the contact of a patient with waterborne pathogens can even lead to death, particularly in patients with compromised immune systems.

When in biofilms, microorganisms are more protected from the environment. Also, cells within biofilms interact more effectively through small secreted molecules (the quorum sensing concept), which enable them to better adapt to local chemical stimuli and to control the population density themselves due to the combination of intracellular signaling with modulation of gene expression (Camilli & Bassler 2006). Typically, Gram-positive bacteria secrete peptides, while Gram-negative bacteria secrete acyl homoserine lactones. As a result of population control, nutrient usage is better regulated and local permanence of the microbial community is more assured. In addition, many pathogenic bacteria are able to migrate from the environment to the human body and vice versa, having the ability to adapt to sudden responses of the host immune system, biofilm formation being a relevant example of microbial adaptation (Jefferson 2004).

For centuries, people who became ill were isolated in places with no natural light and no hygienic and dietetic care. Often, patients admitted for the treatment of an external injury or degenerative disorder died due to infectious diseases such as cholera, typhoid fever or suppuration. However, the development of new diseases and the death of those in isolation were associated with beliefs and superstitions. Over time, although extensive knowledge in microbiology was not yet a fact, the association between hospitalization and infection development was realized.

Conceptual and intellectual development, especially in the eighteenth century, made it possible for hospitals to perform more effective therapeutic actions, with questions raised about the conditions that favored microbial spreading, and by changing the design of hospitals from places where people were admitted to be excluded from social life to institutions of healing and medication (Angerami & Andrade 1999).

Ignaz Philipp Semmelweis, a Hungarian obstetrician, is considered the forerunner in the control of hospital infections. In mid-1840, Semmelweis observed a difference in the number of cases of postpartum infections acquired in two clinics in a hospital in Vienna. In the first clinic, pregnant women were examined by doctors who were constantly present in the autopsy room, while in the second clinic, where the number of infections was substantially lower, the treatments were performed by midwives. On one occasion, one of the doctors was accidentally wounded by a knife while performing a necropsy, and developed an infection similar to that of the mothers. This fact led Semmelweis to conclude that the doctor had been contaminated by the same ‘matter’ affecting the patients, since at that time the concept of the existence of microorganisms was not well established. As a result, in 1847, Semmelweis made it compulsory for all employees of the hospital to wash their hands with a chlorine solution, thus drastically reducing the mortality associated with this problem from 12% to 1.9% (Veiga & Padoveze 2011).

The use of systemic antimicrobial drugs on a large scale began in the 1940s, allowing treatment and the reduction of the number of cases of infections in hospitalized patients. However, military hospitals were soon confronted with Streptoccoccus pyogenes resistance to sulfonamide, a drug widely used at that time for the treatment of wounds. Similarly, the resistance of Mycobacterium tuberculosis to streptomycin occurred shortly after the introduction of this drug on the market. Disturbed by the infections in hospitals, the medical community received with enthusiasm other antimicrobial agents (Santos 2006), but soon after the initial use of penicillin hospitals were confronted with the resistance of Staphylococcus aureus to this drug. In the mid-1950s, outbreaks of resistant Staphylococcal infections were identified around the world, demonstrating the pandemic nature of the phenomenon. Later, in the 1960s, other microorganisms, especially Gram-negative bacteria and fungi, were detected as agents of infections in hospitals (Santos 2006).

Interestingly, antimicrobial resistance was a driving force for health professionals and hospital administrators to recognize the need to establish procedures to monitor, control, and prevent the occurrence of infections developed during hospitalization. Such procedures have to take into account the main groups of occupants in a hospital, formed by patients, professionals, and visitors. These groups are different in terms of health status, exposure to infectious agents, susceptibility to developing diseases, and also regarding cross-transmission issues (Leung & Chan 2006), and all these factors demand great attention.

One of the main factors involved in the persistence of pathogens in the hospital environment is the improper use of sanitizers regarding type and concentration. This action may cause a false sense of disinfection, generating strains tolerant to different treatments performed in the water flow system, where the contaminants may then still proliferate. The same principle applies to the indiscriminate use of antibiotics, which favors subsequent microbial resistance to various treatments. Frequently, no direct relationship can be drawn between the effect of an antimicrobial agent on free cells and on cells organized in a biofilm, since besides the structural and physiological differences between both forms, the adherent cells in a given location may not be the same as those dispersed (Capelletti 2006). The concentration of an antimicrobial agent required to eliminate sessile cells (in biofilms) can be up to 1,000 times higher than that usually used on planktonic cells (in suspension) (Costerton et al. 1987; Capelletti 2006; Lucchesi et al. 2006).

Ferranti et al. (2014), after compiling worldwide information from 125 scientific reports on waterborne healthcare-associated infections published in the period from 1990 to 2012, noticed that representative microorganisms of the families Legionellaceae, Pseudomonadaceae, Burkholderiaceae, Mycobacteriaceae, Enterobacteriaceae, Moraxellaceae, Sphingomonadaceae, Xanthomonadaceae, Flavobacteriaceae, Aeromonadaceae, Campylobacteriaceae, and Gram-negative cells stand out as opportunistic environmental bacteria associated with this problem. A higher number of reports were determined for the families Legionellaceae (38.4% of the total), associated with pneumonia, Pseudomonadaceae (19.2%), frequently detected in respiratory tract and bloodstream infections, and Burkholderiaceae (12.8%), also related to bloodstream infections. The unit seen as the most commonly affected was the ICU, probably due to the frequently compromised physical and immunological condition of the patients. The primary source of Legionnaires' disease was shown to be the hot-water distribution system, while contamination of bottled water and of distilled and sterile water were mainly attributed to contamination by Pseudomonaceae and Burkholderiaceae, respectively. Most of the reports were from Europe (52.8%, of which 14 articles were from France and 11 from Germany) or from American countries (28.8%, of which 28 were from the USA). The occurrence of the problem in developing countries is certainly underreported.

Contact with microorganisms in normal environments is continuous but rarely noticed, unless it causes a disease or other deleterious effects. Indoors, air typically has about 1 million bacteria per cubic meter and tap water around 10 million bacteria per liter. Each microbial ecosystem has particular characteristics according to the environmental conditions of the place where it is installed (Feazel et al. 2009), and in hospitals, the occurrence of airborne contaminants' transmission is quite common. Assuming that the air of a given environment has a microbial concentration of around 1,000 colony-forming units (CFU) per cubic meter, and given that a person breathes normally 30 liters of air per minute, the load of inhaled microorganisms would be approximately 1,800 CFU every hour, while a conventional filter system with an average pore size of 0.5 micron processes about 90 CFU per hour (Lee et al. 2004). The viability of pathogens in the air is provided by water droplets or dust particles suspended in the environment for long periods. Microorganisms suspended in air may then be easily dispersed by air currents and be inhaled by a susceptible host. Fungi of the genus Aspergillus, as an example, can affect approximately 15% of patients with leukemia and transplant, leading to death in around half of this population.

Generally, microorganisms in sessile form have strong virulence factors due to genetic changes that allow the synthesis of new protective substances that act outside and inside the cells. As reported by Kaur & Singh (2014), antifungal resistance is related to the capability of the extracellular matrix to adsorb antimicrobial agents, preventing their free diffusion to the contaminants inside the biofilm and also to the activation of multidrug resistance pumps during biofilm development, which may export biocide molecules from within the cells to the external environment. This combination of characteristics provides favorable cell survival conditions, which make cells in biofilms less susceptible to elimination when compared to the same microorganisms in planktonic form (Morck et al. 2001).

Despite the implementation of prophylactic procedures for the control of airborne contaminants in a given location, the water distribution system frequently acts also as a reservoir of opportunistic microorganisms. Sections of piping where water tends to stagnate provide good growth conditions for pathogens. The concentration of microorganisms dispersed in air increases in areas with intense use of water, which strengths the transmission of pathogens to the environment (Anaissie et al. 2002b). The level of humidity of the surfaces near points of water use can be an important indicator in helping prevent the establishment of contaminants. Even moisture levels as low as a little above 20% may facilitate the development of microorganisms and their dissemination on absorbent structural items such as carpeting, wallboards, and wallpapers if these materials are not properly dried within 72 hours after wetting (Centers for Disease Control and Prevention 2003).

Under adequate growth conditions, a bacterium with a doubling time of around 20 minutes can generate more than two million cells in 8 hours. Given that small amounts of substrate can fulfill the nutritional needs of the contaminants and that concentrations as low as one part per billion of organic matter in 1 milliliter of water may make possible the growth of approximately 9,500 bacteria (Dreeszen 2003), it is clear that water systems have the potential not only to disseminate contaminants but also to support their propagation.

Nosocomial infections originating from water can be transmitted not only by aspiration, but also by contact and ingestion. Many pathogens can survive in hospital water supply systems, transferring antibiotic resistance genes and being implicated in numerous outbreaks.

Among the highest water consumption areas in a hospital are steam generators, hemodialysis equipment, laboratories, surgical materials processing sections, air conditioning systems, and laundries (Anaissie et al. 2002b). The main reservoirs of pathogens in clinical settings reported in the literature are drinking water, water for dialysis, water used for washing medical devices, water used in taps and showers, water lines in dental clinics, and eye washers (Centers for Disease Control and Prevention 2003).

Proper guidelines for the monitoring and prevention of hospital waterborne infections are still limited. In recent years, increases in the occurrence of pathogenic fungi and molds in hospital areas have been detected (Falvey & Streifel 2007), and studies pointing to contaminated surfaces and water supplies as possible sources for aspergillosis (Streifel et al. 1987; Anaissie et al. 2002c) thus raise the need to formulate general and specific guidelines for monitoring hospital water sources. Avoidance of drinking hospital tap water, routine and targeted surveillance cultures for water sources, and hospital staff and patients' education are major measures to control water-associated nosocomial infections.

Monitoring and detection of the transference of pathogens from water to medical instruments are not frequently performed and can lead to incorrect diagnosis of infection. Data provided by a study of nosocomial infections related to water sources (Pall Corporation 2006) showed that devices commonly involved in microbial transmission include not only taps but also nebulizers, affecting patients with respiratory problems, and burns, neonates, patients recovering from cardiac surgery and neurosurgery, as well as the elderly, who are particularly vulnerable. According to the instructions of the Centers for Disease Control and Prevention (2003), for cleaning medical materials, such as endoscopes and bronchoscopes, the water must be of high quality to avoid microbial growth and biofilm formation within these devices.

A study of disinfection in an Italian hospital contaminated with Legionella pneumophila was performed by circulating peracetic acid through the piping system (Ditommaso et al. 2005). In vitro tests showed that the effective concentration for contaminant inactivation in the system was 50 ppm after 5 minutes of contact. Based on these results, a four-step disinfection protocol was then established. In the first step, the disinfectant was used at this dose but for a contact time of 30 minutes. In the second step, the treatment was repeated weekly for 3 weeks, and in the third step, the disinfection was performed in the same conditions of dosage and contact time, and repeated every month for 5 months. Finally, in the last step, the dosage was raised to 1,000 ppm of peracetic acid for a 30 minute exposure period. Despite the multiple disinfection steps, the growth of the same bacteria was detected again 30 days after the procedures, in a concentration even higher than the initial one, due to remaining cells in the form of biofilms within the water pipes, which protected the microorganisms from the disinfecting agent (Ditommaso et al. 2005).

Shower use can provide a source of exposure to microorganisms through aerosolization, as the inside of a showerhead provides a moist, warm, and dark environment that is frequently replenished with nutrients. The heating provided by shower water systems is obviously not hot enough to overcome the transmission of microorganisms, and most of the microbiota found in these devices is composed of groups commonly found in water and soil capable of forming biofilms in favorable conditions (Feazel et al. 2009). A shower system may include a reservoir of bacteria such as Legionella. As a result of the warming of the water in showers, this microorganism may easily spread and reach the respiratory system of the patient. In addition, water drains often cause problems in hospitals if overflow occurs, spreading pathogens on the floor surface (Prade et al. 1995).

Showers and taps in hospitals may also be a significant source of fungi that cause infections in patients with weakened immune systems. In 2001, a detailed study was performed focusing on the route of transmission of Aspergillus related to hospital showers and taps (Warris et al. 2001). In this study, a total of 100 samples of this fungus were collected from air, water, and patients in a hospital in Norway. Among the samples analyzed, 55 were collected from the water system (51% in taps, 44% in the main piping system. and 5% in showers), 25 were obtained from the air, and 20 originated from 13 immunocompromised patients. The samples collected from the water were genetically distinct from those obtained from the air. However, in nine of the 13 patients evaluated, Aspergillus strains genetically similar to those found in the water system were detected.

Although opportunistic pathogens have been cultured from showerheads, little is known about either the prevalence or the nature of the microorganisms that can be aerosolized during showering. To determine the composition of showerhead biofilms and water, in 2009 a study was carried out focusing on the ribosomal RNA gene sequences of biofilms from 45 showerheads from nine sites in the USA (Feazel et al. 2009). The authors found that sequences representative of non-tuberculous mycobacteria and other opportunistic pathogens were highly frequent in many showerhead biofilms.

The development of cyanobacteria (blue algae) in drinking water reservoirs, which culminated in a toxic syndrome known as toxic pneumonia, was reported in Scandinavia (Annadotter et al. 2005). Symptoms such as fever and signs of respiratory tract failure were usually detected in only 1.5 to 6 hours after people had bathed, and the presence of endotoxins dispersed in the aerosols generated during the bath were reported as the probable causative agent.

In Brazil, in 1996, a major outbreak of waterborne nosocomial infection occurred in the town of Caruaru, Pernambuco, affecting 131 patients with chronic renal failure undergoing hemodialysis. Of these, 46 died due to intoxication by microcystin produced by the algae present in the water circuit (FAPESP 1996).

As already mentioned, several pathogens can affect debilitated patients, such as Escherichia coli, Klebsiella, Staphylococcus aureus, Streptococcus pneumoniae, Nocardia spp., Mycobacterium spp., Haemophilus influenzae, and Neisseria meningitidis (Nucci & Maiolino 2000), among others. However, some microorganisms are noteworthy, both in number and type of infection, such as the bacterium Pseudomonas aeruginosa, which is often found in different regions of the body and the environment due to being easily adaptable to different conditions. This bacterium is ubiquitous in water and has been responsible for mortality rates around 30% among patients with pneumonia and sepsis and 60% in burned patients (Angelbeck 2004). Bacteria such as L. pneumophila can cause pneumonia during hospitalization, both through contaminated water and by airborne transmission, while Serratia marcescens may usually be associated with pneumonia and sepsis in patients undergoing chemotherapy. The last mentioned microorganism is slow growing, has invasive properties and the tendency to resist many of the antibiotics used nowadays (Koneman et al. 2001). Additionally, Methylobacteria, a group characterized by being composed of slow-growing microorganisms resistant to chlorine-based treatments, are described as important pathogens transmitted by water (Hiraishi et al. 1995). Also noteworthy are the Mycobacteria, which are capable of survival at extreme temperatures, such as in ice machines and hot water, particularly the intracellulare species, which can persist for more than a year in distilled water. Other bacteria commonly found in drinking water and of great importance regarding the incidence of infections include Stenotrophomonas maltophilia, Aeromonas hydrophila, Acinetobacter spp., Enterobacter spp., Flavobacterium spp., and Burkholderia cepacia (Angelbeck et al. 2006).

Another microorganism associated with major concern is Acinetobacter, due to its rapid ability to develop resistance to many antimicrobial agents, including several antibiotics and heavy metals (Akbulut et al. 2014). This bacteria may demonstrate hemolytic activity, and if infecting a hospitalized person, its discharge through untreated or only partially treated hospital contaminated wastewater may direct it to surface waters, where it is capable of persisting for extended periods, continuing the contamination and spreading cycle.

Fungi are responsible for approximately 8% of total hospital infections, the ones from the genus Aspergillus being the most important regarding infections in immunocompromised patients, particularly those from the species flavus, niger, and fumigatus (ANVISA 2004), which may cause death in about half of the patients affected.

Therefore, taking into account the high prevalence of contaminants in water, various contamination control alternatives complementary to the use of chemical agents are being considered in many hospitals, particularly in Europe. In Germany, since over 40% of infections by Pseudomonas spp. in intensive care units were associated with the use of water, a growing number of disposable filters have been installed in taps and showers for the protection of patients (Reiter 2004). The installation of these filters is considered a very cost-effective alternative if elements such as the expense of rehabilitation of the affected patients and measures to treat the contaminated area are taken into account. It was observed that the installation of only seven filters in a hospital reduced substantially the infections, with savings of approximately 82% in the total usually spent to circumvent the problem.

In severe cases, more aggressive intervention strategies are required and sometimes the only possible measure to prevent or stop the process of infection in patients with high risk is restriction of water use (Squier et al. 2000) and establishing very strict water quality control standards. As an example, healthcare guidelines of the Centers for Disease Control and Prevention (2003) state that for dialysis water, microbial count levels below 200 CFU per milliliter are recommended.

The severity of the problem is illustrated by a case related to the intensive care unit of a hospital in France, in which the bacterium P. aeruginosa was detected in approximately 10% of 657 samples of tap water collected (Rogues et al. 2007). The percentage of transmission of this contaminant particularly through the hands of the local health workers was 14%, with the same strain being isolated from 38 patients. This case report strengthens the concept that among the many sources responsible for nosocomial infections, hospital water is a controllable but surely overlooked one.

Although in Brazil the first hospital infection control committees arose in the 1960s (Padoveze & Fortaleza 2014), the Brazilian National Agency of Sanitary Surveillance (Agência Nacional de Vigilância Sanitária, ANVISA) was only officially instituted in 1999. Since then, this agency has been responsible for the national program of prevention and control of infections related to healthcare facilities. However, to our knowledge, no systematic and detailed studies on nationwide statistics of the occurrence of hospital infections exclusively related to waterborne microorganisms and biofilms are available in the literature.

An analysis of the magnitude of general nosocomial infections in Brazil was performed by the Department of Infection Control in Hospitals of the Ministry of Health, involving 99 hospitals located in different capitals of Brazilian states, totaling 8,624 patients (Prade et al. 1995). The average hospital stay of patients affected by nosocomial infections was 21.7 days and the infection rate was 13%. Prevalence was observed for respiratory tract (28%), followed by surgical (15%), skin (15%), and urinary-related (11%) cases. In a situation different from what is now seen, it was noticed in 1995 that 46% of the patients in surgical clinics and 24% of patients in regular clinics used antibiotics without apparent infection or diagnostic, a practice that favors the development of microbial resistance and complications of further treatment. The southeast region had at that time the highest prevalence of nosocomial infections (16.4%, 37 hospitals), followed by the northeast (13.1%, 27 hospitals), north (11.5%, eight hospitals), south (9.0%, 15 hospitals), and midwest (7.2%, 12 hospitals). The nature of the hospitals was taken into consideration, and public hospitals that had higher rates of infection (18.4%) were compared to teaching hospitals (11.8%) and to those of the private sector (10%).

In 2007, a nationwide search was performed to analyze the existence of committees for hospital infection control, as well as for microbiological laboratories in Brazilian hospitals (ANVISA 2013). According to the reported information, only 4.3% of the evaluated institutions had the support of municipal committees for the control of hospital infections. Moreover, it was detected that in approximately 40% of the hospitals, microbiology laboratories were unavailable. This hampers the adoption of policies for the rational use of antimicrobial agents and also contributes to increase the risk of treatment failure in patients with infectious diseases. It was noted that effective measures for monitoring, evaluating, and reporting of nosocomial infection indicators needed to be improved. This study also shows that hand washing was identified as one of the most relevant items related to infection control, as also stressed by Borges et al. (2012); nevertheless, water itself is seldom recognized as a potential source of contaminants. Obviously, despite hand washing being a simple, inexpensive, and effective measure to prevent the spreading of pathogens in the hospital environment (El-Far & Richtmann 2001), the water used to do it must have adequate microbiological quality.

An investigation performed from 2007 to 2008 in a state hospital of Sumaré, in São Paulo State, showed that from the 862 deaths observed in that period, around 9% were associated with nosocomial infections (Guimarães et al. 2011). Although bacterial resistance was not the focus of that particular study, multidrug resistance rates above 30% for Gram-positive cells and over 40% for Gram-negative cells were detected.

Similarly, according to the National Agency of Sanitary Surveillance in Brazil, in 2007, 64 hospitals reported multidrug resistance of cultures of the bacterium P. aeruginosa, commonly found in water (ANVISA 2008). On average, only 58% of the tested cultures showed susceptibility to at least one of nine major antimicrobials used in conventional antibiotic therapy (amikacin, gentamicin, levofloxacin, ciprofloxacin, meropenem, imipenem, cefepime, ceftazidime, and tazobactam).

In 2013, a survey on the prevalence of healthcare-associated infections in Brazilian hospitals was carried out, in which 91 hospitals were evaluated (Fortaleza et al. 2013). The overall infection rate was 11.1%, varying from 2.5% (hospitals with less than 50 beds) to 18.3% (hospitals with more than 200 beds). The most prevalent infections were pneumonia (3.6%), bloodstream infection (3.5%), surgical site infection (1.4%), urinary tract infection (1.1%), and skin infection (0.4%). The risk factors more frequently identified were: central venous catheter (17.8%), surgery (15.5%), urinary catheter (14.0%), and mechanical ventilators (8.1%). Etiologic agents were identified only in 9.1% (43 of 473) of infections. Gram-negative organisms were more frequent (56.0%) and, among them, Klebsiella spp. (19.0%) and P. aeruginosa (16%) were predominant. Among Gram-positives (35.0%), coagulase-negative Staphylococci were more prevalent (16%) than S. aureus (9.0%) or Enteroccoccus spp. (6%). Yeasts were identified in 9.0% of the infections in this study, and in a former survey, molds were also found to be relevant as hospital waterborne contaminants in Brazil (Varo et al. 2007). The monitoring of seven points of distribution of water in a hemodialysis unit in the state of São Paulo, from April to July 2006, indicated the presence of 116 isolates of filamentous fungi, of which 41% were Trichoderma spp., 25% Cladosporium spp., 14% Aspergillus spp., and 10% Fusarium.

A recent analysis (ANVISA 2013) showed that among the elements recommended for evaluation by the World Health Organization (WHO 2011), the items that better met the international compliance standards with regard to prevention and control of nosocomial infections in Brazilian healthcare institutions are vigilance, technical guides, and environment. Monitoring, evaluation, and relation to public health, however, did not reach adequate levels.

Owing to being among the 10 largest economies in the world, Brazil's situation regarding statistics, prevention and control of infections related to healthcare facilities attributed to waterborne microorganisms and biofilms may be potentially correlated to that of other developing countries in the BRICS group (Brazil, Russia, India, China and South Africa, which represents more than 40% of the world's population) and also of other nations. Therefore, the data presented herein could well serve to instigate more thorough assessment of the problem and also of ways to more effectively deal with it.

In natural environments, microorganisms are mostly found as biofilms, in sessile communities, consisting of microbial associations of interdependent species that can colonize and develop on various types of surfaces. The cells in biofilms are protected by an extracellular polymeric matrix (EPS) of complex and heterogeneous composition, which promotes microbial attachment, proliferation, and differentiation. Owing to displaying hydrophilic and hydrophobic regions, the EPS enables the development of biofilms on different materials (Tsuneda et al. 2003).

Biofilms are formed in a sequence of events, which may vary according to the microbial flora present and cell adaptation to different media (Figure 1). Initially, planktonic cells are transported to the surface of the liquid phase by sedimentation, diffusion, or convection. Then, cell adhesion to the surface occurs, normally through weak forces in an initially reversible step, and afterwards through less reversible forces such as ionic or covalent bonds. After adhesion, cell growth effectively takes place and the structure of the biofilm stabilizes as a whole with the formation of the EPS, through which circulates the fluid in the vicinity of the biofilm. The biofilm is then considered mature, releasing cells as a result of quorum sensing or nutrient level control, biofilm tearing due to continuous liquid flow or by shedding of daughter cells. The released cells may, in turn, colonize other surfaces, restarting the contamination cycle.
Figure 1

Major steps involved in biofilm formation. Planktonic cells attach to the surface, forming an extracellular polymeric matrix that stabilizes the biofilm and through which the fluid is able to circulate. Extracellular and intracellular signaling activates modulation of gene expression, contributing to improved cell resistance and survival. Upon biofilm maturation, daughter cells and microcolonies may be released and dispersed in the fluid stream, thus being able to colonize other surfaces.

Figure 1

Major steps involved in biofilm formation. Planktonic cells attach to the surface, forming an extracellular polymeric matrix that stabilizes the biofilm and through which the fluid is able to circulate. Extracellular and intracellular signaling activates modulation of gene expression, contributing to improved cell resistance and survival. Upon biofilm maturation, daughter cells and microcolonies may be released and dispersed in the fluid stream, thus being able to colonize other surfaces.

Close modal

Currently, the most used methods to prevent and control microbiological contamination on surfaces can be divided basically into three categories: mechanical cleaning procedures, use of sanitizing agents, and use of antimicrobial coatings or membranes. However, there are many factors that may contribute to microbiological contamination of water and culminate in biofilm formation. The misuse of disinfection methods is among the most problematic, because in this way the elimination of the contaminant focus may not be obtained. Some of the most frequently used approaches to disinfect water are compiled in Table 1. Nonetheless, their limitations should be considered when selecting a specific treatment (Schindler 2001).

Table 1

Relevant strategies of water disinfection and their characteristics (compiled from Schindler 2001; EPA 2011; Lin et al. 2011)

Disinfection techniqueAdvantagesDisadvantages
Flow of hot water Does not require specialized equipment Risk of burns 
 Does not involve the use of chemical agents Damage to pipes 
  Difficulty in reaching the whole area in complex distribution systems 
Chlorination Good short-term efficacy Requires periodic analysis of the chlorine level 
 Well understood disinfectant capability Mycobacteria and Legionella are potentially resistant 
 Established dosing technology Ineffective against Cryptosporidium 
  Development of odor, allergic reactions, and carcinogenic byproducts (trihalomethanes) 
  Corrosive 
  Does not permeate effectively in biofilms 
Ionization (copper/silver) Good efficacy in short- and long-term use Water must present low concentration of dissolved solids 
 Easy equipment installation and maintenance High water pH and low ion concentrations may affect the method's efficacy 
 Accumulation of ions inside the biofilm considered as the basis for the prolonged bactericidal effect Requires routine maintenance and monitoring (every week for copper and once every 2 months for silver) 
  Only effective with flow of hot water 
  Corrosive to steel and galvanized pipes 
Exposure to UV light Easy installation Poor penetration in biofilms 
 Pronounced action in planktonic cells Frequent microbial recolonization 
 Does not require the use of chemical agents Water supply should not be turbid for higher treatment efficacy 
 No significant by-product implications Difficulty in reaching the whole area in complex distribution systems 
 Generally highly effective for protozoa, bacteria, and most viruses and particularly for Cryptosporidium Efficacy is reduced by high water flow, presence of organic materials, and high microbial levels 
  High costs 
  No residual effect distributed to the remainder of the system 
Ozonization Good short-term efficacy Requires specialized equipment which is difficult to install and maintain 
 Benefits of destruction of organic micropollutants (pesticides, taste and odour compounds) High costs 
 Strong oxidant and highly effective disinfectant compared with chlorine Action limited to the injection point 
  Fast decomposition of ozone 
  Questionable effect on biofilms 
  Residual effect insufficiently long lasting for distribution over the system under treatment 
Chloramination No significant by-product issues Considerably less effective compared with chlorine 
 Generally less taste and odour issues than chlorine Monochloramine can cause anemia in patients undergoing hemodialysis 
 Stable monochloramine residual penetrates biofilms Increased populations of other microorganisms (Mycobacterium species) 
 Wider working pH range than copper/silver ionization and chlorine Presence of nitrogen by-products and increased lead leaching in drinking water 
  Use of monochloramine generally limited to municipal water treatment plants 
Disinfection techniqueAdvantagesDisadvantages
Flow of hot water Does not require specialized equipment Risk of burns 
 Does not involve the use of chemical agents Damage to pipes 
  Difficulty in reaching the whole area in complex distribution systems 
Chlorination Good short-term efficacy Requires periodic analysis of the chlorine level 
 Well understood disinfectant capability Mycobacteria and Legionella are potentially resistant 
 Established dosing technology Ineffective against Cryptosporidium 
  Development of odor, allergic reactions, and carcinogenic byproducts (trihalomethanes) 
  Corrosive 
  Does not permeate effectively in biofilms 
Ionization (copper/silver) Good efficacy in short- and long-term use Water must present low concentration of dissolved solids 
 Easy equipment installation and maintenance High water pH and low ion concentrations may affect the method's efficacy 
 Accumulation of ions inside the biofilm considered as the basis for the prolonged bactericidal effect Requires routine maintenance and monitoring (every week for copper and once every 2 months for silver) 
  Only effective with flow of hot water 
  Corrosive to steel and galvanized pipes 
Exposure to UV light Easy installation Poor penetration in biofilms 
 Pronounced action in planktonic cells Frequent microbial recolonization 
 Does not require the use of chemical agents Water supply should not be turbid for higher treatment efficacy 
 No significant by-product implications Difficulty in reaching the whole area in complex distribution systems 
 Generally highly effective for protozoa, bacteria, and most viruses and particularly for Cryptosporidium Efficacy is reduced by high water flow, presence of organic materials, and high microbial levels 
  High costs 
  No residual effect distributed to the remainder of the system 
Ozonization Good short-term efficacy Requires specialized equipment which is difficult to install and maintain 
 Benefits of destruction of organic micropollutants (pesticides, taste and odour compounds) High costs 
 Strong oxidant and highly effective disinfectant compared with chlorine Action limited to the injection point 
  Fast decomposition of ozone 
  Questionable effect on biofilms 
  Residual effect insufficiently long lasting for distribution over the system under treatment 
Chloramination No significant by-product issues Considerably less effective compared with chlorine 
 Generally less taste and odour issues than chlorine Monochloramine can cause anemia in patients undergoing hemodialysis 
 Stable monochloramine residual penetrates biofilms Increased populations of other microorganisms (Mycobacterium species) 
 Wider working pH range than copper/silver ionization and chlorine Presence of nitrogen by-products and increased lead leaching in drinking water 
  Use of monochloramine generally limited to municipal water treatment plants 

Several strategies can be employed to control the infection rates originating from water in hospitals (Curtis 2008), including simple measures such as using sterile water as drinking water and in showers. Also, cleaning of showers with detergents and phenolic compounds, heating water at temperatures above 50 °C, and immediate repair of leaks and damages resulting from water flow are rather effective. More elaborate strategies are also available, such as water treatment with UV light or ionization systems based on copper and silver. The use of chemical agents is also indicated, however most of them, even at dosages above the usual, are unable to completely and permanently eradicate biofilms already installed, which develop again and may turn resistant (Angelbeck et al. 2006).

In general, the concentration of chlorine necessary to eradicate most of the microorganisms present in water is approximately 0.3 milligrams per liter. However, even with the addition of free chlorine in water pipes at concentrations as high as 4.3 milligrams per liter, some coliforms can survive (LeChevallier et al. 1984). This can be attributed to some common factors in water circuits: the chlorine added may not reach all areas of the water distribution network in sufficient quantity for its action, and part of the chlorine added may react with traces of pre-existing organic matter or corrosion products, among other possibilities. Even portions of biofilms detached from surfaces as a result of the action of disinfectants can be problematic. Such fragments can serve as a source of easily assimilable organic carbon for the maintenance of the living microorganisms remaining in the system.

In most cases, the cost for the treatment of biofilm-related contamination is much greater than the amount that would be spent if there were actions to prevent its occurrence. As mentioned previously, a current alternative, very attractive and with proven efficacy, is the use of filters at points of final consumption, such as in taps and showers (Ortolano et al. 2005; Sheffer et al. 2005; Exner et al. 2005; Lin et al. 2011). Point-of-use water filtration is one of the particular strategies recommended by Lin et al. (2011) for emergency disinfection methods in the case of hospital-acquired Legionnaires' disease, in addition to the use of superheat-and-flush disinfection and/or shock chlorination.

The high efficiency of the approach based on installing point-of-use water filters was recently reported by Zhou et al. (2014). The filters were capable of eliminating Legionella spp., P. aeruginosa, Mycobacterium spp., and filamentous fungi from the tap water of a liver transplant unit in a hospital in Shanghai, China, also reducing the incidence of colonization and infection with Gram-negative bacteria by 47%.

Another example of the successful use of the filtration strategy is described by Vianelli et al. (2006), who reported the use of disposable filters with 0.2 μm pore size at points of consumption such as taps and showers in bathrooms at hematology and oncology areas in an Italian hospital. Such an approach not only allowed a significant reduction of P. aeruginosa bacteremia, but also contributed to the control of infection outbreaks involving the same organism. The authors also point out that despite the increase in the annual operating costs due to changing the filters weekly, a significant contribution to the reduction of morbidity, consumption of antibiotics, and length of stay of patients in the hospital was noticed.

The filtering approach can be used as a complementary procedure to chemical disinfection treatments, with the advantage of capturing microorganisms that may have survived exposure to these agents or have not been reached in stagnant regions of the piping system.

A comparative study of different strategies to control Legionella spp. in a hot water supply, conducted at a university hospital in Italy for 10 years (Marchesi et al. 2011), showed that filters placed directly in water use points perform best with respect to the reduction of contamination, followed by the use of heating, chlorine dioxide, heat shock, and hyperchlorination. The use of chlorine dioxide, however, is the least expensive procedure followed by thermal shock, hyperchlorination, heating, and filtration.

Although cost is a relevant factor in the analysis, strategies for high efficacy in microbial control of water and based on a combination of two or more distinct principles of disinfection can be vitally important in sectors where hospital treatments are carried out on severely immunocompromised patients. Strategies also comprehending the use of devices and materials of extremely low risk to patients and to the environment, such as those based on the use of natural-origin bioactive compounds like chitosan, are being increasingly considered, mostly to coat surfaces prone to short-time contact with moisture.

Chitosan, a polymer obtained by deacetylation of chitin, a polysaccharide that has a structure similar to cellulose, has attracted great interest for application in the biomedical area lately due to its antimicrobial properties (as a biocide and biostatic agent) (Chandy & Sharma 1990). Its use as a natural coagulant for the treatment of drinking water in the isolated form or together with other approaches is also well documented (Lee et al. 1992; Eikebrokk & Saltnes 2001; Fabris et al. 2010; Khaira et al. 2013).

Besides these attributes, chitosan is a versatile material that can be used alone or in combination with other compounds, aiming at improving its physical, mechanical, and/or biological characteristics for specific applications. It can be processed in different forms, such as solutions, gels, particles, dense and porous films and membranes, among others, and has low toxicity to humans. As a consequence of all these attractive characteristics, added to its high availability, its use in the development of biomaterials has been increasingly investigated in recent years, with great emphasis on the production of wound dressings (Jayakumar et al. 2011).

Chitosan has the capacity to inhibit the growth of a wide variety of bacteria, molds, and yeasts (Singla & Chawla 2001; Raafat & Sahl 2009). However, the presentation form of the final material can significantly influence its antimicrobial activity (Foster & Butt 2011). The high density of positive charges in chitosan molecules is highlighted in several studies as one of the main factors involved in its mode of action, propitiating the interaction with microbial cells and their toxins, which are typically negatively charged. The cell wall composition of many organisms commonly found in water, such as cyanobacteria, is similar to that of Gram-negative bacteria, which also have negative charges in their surface (Cossich 2000). The reproductive structures of some filamentous fungi are also negatively charged (Dunlap et al. 2005), as well as the surface of common yeasts (Saccharomyces spp. and Candida spp.), which in all of the situations described would favor the interaction of cells with chitosan. In this sense, chitosan is successfully used as a flocculating agent to remove impurities in chemical and biological water treatment (Strand et al. 2002).

Studies involving the use of chitosan as a coating for surfaces indicate that this method of antimicrobial protection provides a promising field of application in the control of nosocomial pathogens (Wang et al. 2012; Cobrado et al. 2013). However, the intrinsic bactericidal activity of chitosan seems to be more intense in preparations in the form of solutions or gels than in neutralized materials (Foster & Butt 2011). It is assumed that there is a significant contribution to the chitosan antimicrobial effect from the organic acids commonly used to solubilize this polysaccharide due to the pH reduction of its solutions or gels (Chung et al. 2003; Fujimoto et al. 2006). Consequently, the antimicrobial activity observed for chitosan and its derivatives is perceptible only when the pH is below the dissociation constant of the amino groups of the respective compounds. This mechanism is not limited to soluble forms of chitosan, but is also verified in solid chitosan samples (Kong et al. 2010). Thus, when the use of neutralized chitosan films at basic or neutral pH conditions is desired, the chitosan device should ideally be combined with compounds having microbicidal activity to more effectively control the development of microbial biofilms.

Styrene-acrylic coupons coated with this polymer and exposed to clinically relevant microorganisms such as Staphylococcus epidermidis and Candida albicans showed enhanced antifouling activity in comparison to coupons treated with conventional antimicrobial agents (Carlson et al. 2008). In the same type of application, chitosan in the form of a neutralized film in combination with the antibiotic rifampin has already been successfully used for controlling the development of S. epidermidis and S. aureus biofilms (Cao & Sun 2009).

Other prospects for application of this biopolymer in microbial control of water used in hospitals should be further explored, both directly as a potential antimicrobial agent in solution and in an indirect way as a matrix for the incorporation of other antimicrobial agents.

The number of cases of infections of nosocomial origin associated with systems of water distribution in hospitals around the world is highly significant. The development and adoption of more effective measures to prevent its progression is an assured need, as is providing qualified information on this matter to professionals working in healthcare facilities and also to patients and their companions, mostly in developing countries, where activities on prevention, monitoring, and control of waterborne contaminants tend to be more limited. It is essential that when the use of antimicrobial agents cannot be avoided to overcome waterborne pathogens' replication and spreading, these compounds should be employed in a rational way to minimize the major problem of development of microbial resistance to their presence. Despite the fact that filtration systems are particularly cost-effective as alternative or complementary approaches to control waterborne contaminants in hospitals, the use of antimicrobial agents of natural origin, such as chitosan, should be more frequently considered for the purpose of reducing the risk of nosocomial infections together with other useful strategies.

The authors are grateful to the Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) and to the Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) for support in the development of this work.

Anaissie
E. J.
Penzak
S. R.
Dignani
M. C.
2002a
The hospital water supply as a source of nosocomial infections: a plea for action
.
Arch. Intern. Med.
162
(
13
),
1483
1492
.
Anaissie
E. J.
Stratton
S. L.
Dignani
M. C.
Summerbell
R. C.
Rex
J. H.
Monson
T. P.
Spencer
T.
Kasai
M.
Francesconi
A.
Walsh
T. J.
2002c
Pathogenic Aspergillus species recovered from a hospital water system: a three-year prospective study
.
Clin. Infect. Dis.
34
(
6
),
780
789
.
Angelbeck
J. A.
2004
Stopping Legionella and other waterborne pathogens in their tracks – a global perspective
.
Water Cond. Purif.
October
,
62
65
.
Angelbeck
J. A.
Ortolano
G. A.
Canonica
F. P.
Cervia
J. S.
2006
Hospital water: a source of concern for infections
.
Managing Infect. Control
6
(
1
),
44
54
.
Angerami
E. L. S.
Andrade
D.
1999
Reflexões acerca das infecções hospitalares às portas do terceiro milênio
.
Medicina
32
,
492
497
.
ANVISA (Agência Nacional de Vigilância Sanitária, National Agency of Sanitary Surveillance, Brazil)
2004
Manual de Microbiologia Clínica para o Controle de Infecção em Serviços de Saúde
.
(accessed 19 September 2014)
.
ANVISA (Agência Nacional de Vigilância Sanitária, National Agency of Sanitary Surveillance, Brazil)
2008
Relatório de Atividades
.
(accessed 13 July 2014)
.
ANVISA (Agência Nacional de Vigilância Sanitária, National Agency of Sanitary Surveillance, Brazil)
2013
Programa Nacional de Prevenção e Controle de Infecções Relacionadas à Assistência à Saúde (2013–2015)
.
2013 (accessed 24 June 2015)
.
APM (Associação Paulista de Medicina, Paulista Medical Association, Brazil)
2006
Infecção hospitalar leva cerca de 45mil pessoas à morte por ano no Brasil
.
(accessed 28 March 2014)
.
Borges
L. F. A.
Rocha
L. A.
Nunes
M. J.
Gontijo Filho
P. P.
2012
Low compliance to handwashing program and high nosocomial infection in a Brazilian hospital
.
Interdiscip. Perspect. Infect. Dis.
2012, article ID 579681, 5 pp
.
Camilli
A.
Bassler
B. L.
2006
Bacterial small-molecule signaling pathways
.
Science
311
(
5764
),
1113
1116
.
Capelletti
R. V.
2006
Evaluation of biocide activity on biofilms formed in cutting fluid employed in metal working industry
.
Master's dissertation
,
School of Chemical Engineering, University of Campinas, Campinas
,
São Paulo
,
Brazil
.
Carlson
R. P.
Taffs
R.
Davison
W. M.
Stewart
P. S.
2008
Anti-biofilm properties of chitosan-coated surfaces
.
J. Biomater. Sci. Polym. Ed.
19
(
8
),
1035
1046
.
Centers for Disease Control and Prevention
2003
Guidelines for environmental infection control in health-care facilities
. (
accessed 2 May 2012
).
Chandy
T.
Sharma
C. P.
1990
Chitosan as biomaterial
.
Biomater. Artif. Cells Artif. Organs.
18
,
1
24
.
Cobrado
L.
Silva-Dias
A.
Azevedo
M. M.
Pina-Vaz
C.
Rodrigues
A. G.
2013
In vivo antibiofilm effect of cerium, chitosan and hamamelitannin against usual agents of catheter-related bloodstream infections
.
J. Antimicrob. Chemother.
68
(
1
),
126
130
.
Cossich
E. S.
2000
Biossorção de cromo (III) pela biomassa da alga marinha Sargassum sp. [Chrome biosorption (III) the biomass of seaweed Sargassum sp.]
.
Doctorate thesis
,
School of Chemical Engineering, University of Campinas, Campinas
,
São Paulo
,
Brazil
.
Costerton
J. W.
Cheng
K. J.
Geesey
G. G.
Ladd
T. I.
Nickel
J. C.
Dasgupta
M.
Marrie
T. J.
1987
Bacterial biofilms in nature and disease
.
Annu. Rev. Microbiol.
41
,
435
464
.
Ditommaso
S.
Biasin
C.
Giacomuzzi
M.
Zotti
C. M.
Cavanna
A.
Moiraghi
A. R.
2005
Peracetic acid in the disinfection of a hospital water system contaminated with Legionella species
.
Infect. Control. Hosp. Epidemiol.
6
(
5
),
490
493
.
Dreeszen
P. H.
2003
Biofilm: The Key to Understanding and Controlling Bacterial Growth in Automated Drinking Water Systems
, 2nd edn.
Edstrom Industries
,
Waterford, WI
,
USA
.
Dunlap
C. A.
Biresaw
G.
Jackson
M. A.
2005
Cell surface properties of blastospores of the entomopathogenic fungus Paecilomyces fumosoroseus
. In
XLV Annual Meeting of American Phytopathological Society, Caribean Division
,
San José
,
Costa Rica
.
Ecker
D. J.
Carroll
K. C.
2005
Investments in high payoff technologies could reduce toll of infections
.
ASM News
71
(
12
),
576
581
.
Eikebrokk
B.
Saltnes
T.
2001
Removal of natural organic matter (NOM) using different coagulants and lightweight expanded clay aggregate filters
.
Water Sci. Technol. Water Supply
1
(
2
),
131
140
.
El-Far
F.
Richtmann
R.
2001
Prevenir ainda é a melhor opção: a luta contra os Gram-positivos multirresistentes
.
Revista Prática Hospitalar
13
,
7
9
.
EPA
2011
Water Treatment Manual Disinfection
.
Environmental Protection Agency
,
Wexford
,
Ireland
,
200 pp
.
Exner
M.
Kramer
A.
Lajoie
L.
Gebel
J.
Engelhart
S.
Hartemann
P.
2005
Prevention and control of health care-associated waterborne infections in health care facilities
.
Am. J. Infect. Control.
33
(
5
),
S26
S40
.
Fabris
R.
Chow
C. W. K.
Drikas
M.
2010
Evaluation of chitosan as a natural coagulant for drinking water treatment
.
Water Sci. Technol.
61
(
8
),
2119
2128
.
FAPESP (Fundação de Amparo à Pesquisa do Estado de São Paulo, São Paulo Research Foundation, Brazil)
1996
Toxina causou a tragédia da hemodiálise – algas encontradas na água usada em Caruaru liberaram substância que acabou provocando hepatite [Toxin caused hemodialysis tragedy – Algae found in water used in Caruaru released substance that eventually caused hepatitis]
.
(accessed 21 May 2012)
.
Feazel
L. M.
Baumgartner
L. K.
Peterson
K. L.
Frank
D. N.
Harris
J. K.
Pace
N. R.
2009
Opportunistic pathogens enriched in showerhead biofilms
.
Proc. Natl. Acad. Sci. U S A
106
(
38
),
16393
16399
.
Ferranti
G.
Marchesi
I.
Favale
M.
Borella
P.
Bargellini
A.
2014
Aetiology, source and prevention of waterborne healthcare-associated infections: a review
.
J. Med. Microbiol.
63
,
1247
1259
.
Fortaleza
C. M. C. B.
Padoveze
M. C.
Kiffer
C.
Barth
A. L.
Carneiro
I. C. R. S.
Rodrigues
J. L. N.
Filho
L. S.
Mello
M. J. G.
Asensi
M. D.
Filho
P. P. G.
Pereira
M. S.
Rocha
M.
Kuchenbecker
R. S.
Medeiros
E. S.
Pignatari
A. C. C.
2013
Countrywide prevalence study of healthcare-associated infections in Brazilian hospitals: preliminary results
.
Antimicrob. Resist. Infect. Control.
2
, (
Suppl 1
),
O26
.
Foster
L. J.
Butt
J.
2011
Chitosan films are not antimicrobial
.
Biotechnol. Lett.
33
(
2
),
417
421
.
Guimarães
A. C.
Donalisio
M. R.
Santiago
T. H. R.
Freire
J. B.
2011
Mortality associated with nosocomial infection, occurring in a general hospital of Sumaré-SP, Brazil
.
Rev. Bras. Enferm.
64
(
5
),
684
689
.
Hiraishi
A.
Furuhata
K.
Matsumoto
A.
Koike
K. A.
Fukuyama
M.
Tabuchi
K.
1995
Phenotypic and genetic diversity of chlorine-resistant Methylobacterium strains isolated from various environments
.
Appl. Environ. Microbiol.
61
,
2099
2107
.
Jayakumar
R.
Prabaharan
M.
Sudheesh Kumar
P. T.
Nair
S. V.
Tamura
H.
2011
Biomaterials based on chitin and chitosan in wound dressing applications
.
Biotechnol. Adv.
29
(
3
),
322
337
.
Jefferson
K. K.
2004
What drives a bacteria to produce a biofilm?
FEMS Microbiol. Lett.
236
,
163
173
.
Kaur
S.
Singh
S.
2014
Biofilm formation by Aspergillus fumigatus
.
Med. Mycol.
52
(
1
),
2
9
.
Khaira
G. K.
Kumarya
R.
Chibber
M.
Ghosh
M.
2013
Development of a quaternized chitosan with enhanced antibacterial efficacy
.
J. Water Health
11
(
3
),
410
418
.
Koneman
E. W.
Allen
S. D.
Janda
W. M.
Schreckenberger
P. C.
Winn
J. W. C.
2001
Diagnóstico Microbiológico
, 5th edn
[Microbiological Diagnosis]
.
Guanabara Koogan
,
Rio de Janeiro – RJ
,
Brazil
.
Kong
M.
Chen
X. G.
Xing
K.
Park
H. J.
2010
Antimicrobial properties of chitosan and mode of action: a state of the art review
.
Int. J. Food Microbiol.
144
(
1
),
51
63
.
Lebeaux
D.
Chauhan
A.
Rendueles
O.
Beloin
C.
2013
From in vitro to in vivo models of bacterial biofilm-related infections
.
Pathogens
2
(
2
),
288
356
.
LeChevallier
M. W.
Hassenauer
T. S.
Camper
A. K.
McFeters
G. A.
1984
Disinfection of bacteria attached to granular activated carbon
.
Appl. Environ. Microbiol.
48
(
9
),
918
923
.
Lee
S.-I.
Koopman
B.
Lincoln
E. P.
1992
Effect of physicochemical variables on algal autoflotation
.
Water Sci. Technol.
26
(
7–8
),
1769
1778
.
Leung
M.
Chan
H. S.
2006
Control and management of hospital indoor air quality
.
Med. Sci. Monit.
12
(
3
),
SR17
SR23
.
Lucchesi
E. G.
Capelletti
R. V.
Eguchi
S. Y.
Moraes
A. M.
2006
Desenvolvimento de sistema simplificado para a formação de biofilmes in vitro e avaliação de seu desempenho em testes de susceptibilidade a biocidas
. In:
XVI Congresso Brasileiro de Engenharia Química
,
Recife, PE
,
Brazil
.
Marchesi
I.
Marchegiano
P.
Bargellini
A.
Cencetti
S.
Frezza
G.
Miselli
M.
Borella
P.
2011
Effectiveness of different methods to control Legionella in the water supply: ten-year experience in an Italian university hospital
.
J. Hosp. Infect.
77
(
1
),
47
51
.
Morck
D. W.
Olson
M. E.
Ceri
H.
2001
Microbial biofilms: preservation, control and removal
. In:
Disinfection, Sterilization and Preservation
(
Block
S. S.
, ed.).
Lippincott Williams & Wilkins
,
Philadelphia, PA
,
USA
.
Nucci
M.
Maiolino
A.
2000
Infecções em transplante de medula óssea [Infection in bone marrow transplantation]
.
Medicina
33
,
278
293
.
Ortolano
G. A.
McAlister
M. B.
Angelbeck
J. A.
Schaffer
J.
Russell
R. L.
Maynard
E.
Wenz
B.
2005
Hospital water point-of-use filtration: A complementary strategy to reduce the risk of nosocomial infection
.
Am. J. Infect. Control.
33
, (
5 Suppl 1
),
S1
19
.
Pall Corporation
2006
Safe Water for Patient Care
. (
accessed 15 May 2012
).
Prade
S. S.
Oliveira
S. T.
Rodriguez
R.
Nunes
F. A.
Netto
E. M.
Pereira
M.
1995
Estudo brasileiro da magnitude das infecções hospitalares em hospitais terciários [Brazilian study the magnitude of nosocomial infections in tertiary hospitals]
.
J. Hosp. Infect. Control
2
,
11
24
.
Reiter
M.
2004
Nosocomial infections: concepts for prevention focus increasingly on water-borne contaminants
. In
Annual Congress of the German Society for Hospital Hygiene
,
Berlin
,
Germany
.
(accessed 15 September)
.
Rogues
A. M.
Boulestreau
H.
Lashéras
A.
Boyer
A.
Gruson
D.
Merle
C.
Castaing
Y.
Bébear
C. M.
Gachie
J. P.
2007
Contribution of tap water to patient colonization with Pseudomonas aeruginosa in a medical intensive care unit
.
J. Hosp. Infect.
67
(
1
),
72
78
.
Santos
A. A. M.
2006
O modelo brasileiro para o controle das infecções hospitalares: após vinte anos de legislação, onde estamos e para onde vamos?
Master's dissertation
,
Health Sciences, Federal University of Minas Gerais
,
Belo HGorizonte, MG
,
Brazil
.
Schindler
P.
2001
Comments on investigations on the reduction of Legionella. Pall Corporation
. .
Sheffer
P. J.
Stout
J. E.
Wagener
M. M.
Muder
R. R.
2005
Efficacy of new point-of-use water filter for preventing exposure to Legionella and waterborne bacteria
.
Am. J. Infect. Control.
33
, (
5 Suppl 1
),
S20
S25
.
Singla
A. K.
Chawla
M.
2001
Chitosan: some pharmaceutical and biological aspects – an update
.
J. Pharm. Pharmacol.
53
(
8
),
1047
1067
.
Squier
C.
Yu
V. L.
Stout
J. E.
2000
Waterborne nosocomial infections
.
Curr. Infect. Dis. Rep.
2
(
6
),
490
496
.
Strand
S. P.
Nordengen
T.
Ostgaard
K.
2002
Efficiency of chitosans for flocculation of different bacteria
.
Water Res.
36
(
19
),
4745
4752
.
Streifel
A.
Stevens
P.
Rhame
F.
1987
In-hospital source of airborne Penicillium species spores
.
J. Clin. Microbiol.
25
(
1
),
1
4
.
Tsuneda
S.
Aikawa
H.
Hayashi
H.
Yuasa
A.
Hirata
A.
2003
Extracellular polymeric substances responsible for bacterial adhesion onto solid surface
.
FEMS Microbiol Lett.
223
(
2
),
287
292
.
Varo
S. D.
Martins
C. H. G.
Cardoso
M. J. O.
Sartori
F. G.
Montanari
L. B.
Pires-Gonçalves
R. H.
2007
Isolamento de fungos filamentosos em água utilizada em uma unidade de hemodiálise [Isolation of filamentous fungi from water used in a hemodialysis unit]
.
Rev. Soc. Bras. Med. Trop.
40
(
3
),
326
331
.
Veiga
J. F. S.
Padoveze
M. C.
2011
Infecção hospitalar. Centro de vigilância epidemiológica Prof. Alexandre Vranjac, Secretaria de Estado da Saúde de São Paulo, 2003
. (
accessed 10 July 2014
).
Vianelli
N.
Giannini
M. B.
Quarti
C.
Sabattini
M. A. B.
Fiacchini
M.
de Vivo
A.
Graldi
P.
Galli
S.
Nanetti
A.
Baccarani
M.
Ricci
P.
2006
Resolution of a Pseudomonas aeruginosa outbreak in a hematology unit with the use of disposable sterile water filters
.
Haematologica
91
(
7
),
983
985
.
Warris
A.
Gaustad
P.
Meis
J. F. G. M.
Voss
A.
Verweij
P. E.
Abrahamsen
T. G.
2001
Recovery of filamentous fungi from water in a paediatric bone marrow transplantation unit
.
Hosp. Infect.
47
(
2
),
143
148
.
WHO
2011
Core components for infection prevention and control programs. Assessment tools for IPC programmes
.
World Health Organization
,
Geneva
,
Switzerland
.