Abstract
We conducted a survey to investigate the distribution of bacteria recovered from the bidet toilets at a district hospital. The nozzle surface and spray water of 192 bidet toilets were sampled for contamination. Of the 192 toilets sampled, the nozzle surface of 167 (87%) and the spray water of 181 (94%) were found to be contaminated by one or more of the following organisms: Enterobacteriaceae, Enterococcus spp., Staphylococcus spp., non-glucose-fermenting rods, other Gram-negative bacteria, other Gram-positive bacteria, and Candida spp. An extended spectrum of β-lactamase producing Escherichia coli was found in one nozzle surface and one spray water. The frequency of colonization with 104 or more recovered from the nozzle surface was significantly greater in the toilets scrubbed every week than that in the units scrubbed every day, but that from the spray water was not significantly different between the groups. The nozzle surface and the spray water in the bidet toilets were contaminated with a wide range of bacteria. Because the interval of scrubbing the toilets did not have an influence on the contamination of the spray water, self-cleaning mechanisms of spray water should be developed to prevent patients' possible infections.
INTRODUCTION
Electric bidet toilets are automatic devices that deliver a jet of water to clean the anus after defecation. Since the first Japanese-made electric bidet toilets were introduced in the Japanese market in 1967, they have been steadily gaining popularity and have been developed to incorporate different functions to improve user comfort. Today, the user can select the water pressure and temperature they prefer, as well as water angle, from narrow to wide. In Japan, 79% of households have bidet toilets (Cabinet Office Government of Japan 2017). We conducted a survey to investigate the use of bidet toilets among community-dwelling Japanese people and found that 55% of 4,963 responders used bidet toilets either before or after defecation (Tsunoda et al. 2016).
Bidet toilets have been increasingly installed in schools, airports, hotels, and other public facilities. These units are also found in many hospital lavatory facilities. However, the patient's possible infectious risk has not been assessed sufficiently. As the distribution of antimicrobial-resistant bacteria in hospitals is higher compared with the community (Roca et al. 2015), concerns have been reported regarding the potential risk that patients may be exposed to antimicrobial-resistant bacteria in the warm-water sprayed from bidet toilets’ nozzles (Iyo et al. 2016; Kanayama Katsuse et al. 2017). Iyo et al. (2016) surveyed a sample of 127 bidet toilets at a university hospital and detected bacterial contamination of spray water, and found Escherichia coli and Pseudomonas aeruginosa in 5% and 2% of the spray water, respectively. Kanayama Katsuse et al. (2017) surveyed a sample of 292 bidet toilets at a university hospital and explored bacterial contamination of both the nozzle surface and toilet seats, and found that an extended spectrum of β-lactamase (ESBL) producing E. coli and methicillin-resistant Staphylococcus aureus was recovered from the nozzle surface.
Although the bacterial survey of spray water alone or both the toilet seats and the nozzle surface was valuable, the correlation between the contamination of the nozzle surface and the spray water may be more important to know the equipped cleaning function of the nozzle before and after use. In addition, whether the severity of bacterial contamination of bidet toilets may be affected by the interval of scrubbing the dirt from these units by a cleaning staff remains unknown. Therefore, we surveyed bacterial contamination of the nozzle surface and the spray water of bidet toilets at the Kameda Medical Center and explored its relation to the interval of scrubbing these units.
METHODS
Bidet toilets
To evaluate the hygiene status of bidet toilets, a survey of their microbial communities was conducted at a district hospital between February and March 2018. A total of 192 tank-type bidet toilets were surveyed, of those 103 were in an inpatient ward (48 individual, 55 shared), 34 were in an outpatient clinic, and 55 were in a research building for an employee. Fifty-three toilets were for men only, 67 for women only, and 72 were not fixed or shared. Bidet toilets for patients (n = 137) were scrubbed every day and those for employees (n = 55) every week by cleaning staff. The nozzle was scrubbed with a brush using Toilet HeiterTM (Kao Co., Ltd, Tokyo, Japan) which contains hypochlorous acid. Between 5 and 13 years had passed since these bidet toilets had been installed, and all were functioning properly.
Sampling protocol
Nozzle surface
The nozzle surface was sampled firstly using swabs before spray water. Samples were placed in 1 ml of sterile physiological saline, centrifuged with 3,000 G for 20 min, and its sediment was used for samples.
Spray water
Spray water was collected directly as it came out of the nozzle. About 50 ml of the spray water from the nozzle was collected in sterilized bottles, centrifuged with 3,000 G for 20 min, and its sediment was used for samples.
Tap water
Tap water for control specimens was collected from faucets in the restrooms which were surveyed. Of the 123 samples of tap water analyzed, 82 were in an inpatient ward, 17 were in an outpatient clinic, and 24 were in a research building. To eliminate as much contamination as possible on the faucet, the tap water was allowed to run for about 30 s before samples were collected for testing for microorganisms. About 50 ml of the tap water was collected in sterilized bottles, centrifuged with 3,000 G for 20 min, and its sediment was used for samples.
Bacterial analysis
Samples were inoculated on Trypticase Soy Agar II with 5% Sheep Blood/Drigalski Lactose Agar (Nippon Becton Dickinson Co., Ltd, Tokyo, Japan). Also, these were inoculated on CHROMager Orientation (CHO)/ESBL medium (Kanto Chemical Co. Inc., Tokyo, Japan), which differentiates Gram-negative bacteria based on the pigmentation and detection of ESBL or metallo-β-lactamase (MBL) producing organisms following incubation. To detect vancomycin-resistant Enterococci (VRE), the broth microdilution MIC test (National Committee for Clinical Laboratory Standards 1993) was used.
Following incubation at 37 °C under aerobic conditions for 48 h, the color and intensity of the colonies on the media were recorded according to the coloration types provided by the manufacturers' instructions. Each type of colony was counted for the colony-forming units (CFU) by the microbiological technologists, where the greater number of colonies was roughly judged as 104, 105, and 106 CFU or more, respectively. Thin colonies under 100 CFU were counted as an actual number. All colonies were identified using the matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) system (Bruker Daltonics GmbH, Germany) (Veloo et al. 2011).
Statistical analysis
Chi-squared test or Fisher's exact test was used for the comparison of the pattern of bacterial colonization of toilets between the groups, or the frequency of bacterial colonization with 104 CFU or more, recovered from the toilets sampled between the groups.
RESULTS
Table 1 shows the pattern of bacterial colonization of the 192 bidet toilets sampled, where the nozzle surface of 167 (87%) and the spray water of 181 (94%) were found to be contaminated. Figure 1 showed the detection frequency of colonies by CFU recovered from the toilets. Twenty-nine colonies with 104 CFU, 5 colonies with 105 CFU, and 7 colonies with 106 CFU or more were recovered from the nozzle surface (Figure 1(a)). Similarly, 13 colonies with 104 CFU and 2 colonies with 105 CFU and 106 CFU or more, respectively, were isolated from the spray water (Figure 1(b)). The mean standard deviation number of thin colonies recovered from the nozzle surface was 14.4 (16.2) CFU, and that done from the spray water was 16.3 (17.1) CFU. Of 123 samples of tap water, bacteria colonization was recovered from one toilet in an inpatient ward, which was identified as Sphingomonas paucimobilis.
Nozzle surface contamination . | Spray water contamination . | No. (%) of toilets . |
---|---|---|
+ | + | 161 (83.9) |
+ | – | 6 (3.1) |
– | + | 20 (10.4) |
– | – | 5 (2.6) |
Nozzle surface contamination . | Spray water contamination . | No. (%) of toilets . |
---|---|---|
+ | + | 161 (83.9) |
+ | – | 6 (3.1) |
– | + | 20 (10.4) |
– | – | 5 (2.6) |
+, positive for bacteria; –, negative for bacteria.
Table 2 shows the organisms recovered from the nozzle surface and the spray water. Enterobacteriaceae were isolated from 11 (5.7%) bidet toilets. E. coli was recovered from five nozzle surfaces and four spray water; of these, ESBL-producing E. coli was found in one nozzle surface and one spray water in a different inpatient ward. Klebsiella spp. were found from one nozzle surface and two spray water, although Klebsiella oxytoca or Klebsiella pneumonia was not recovered. Enterococcus spp. were isolated from seven nozzle surfaces, although no VRE were detected. Staphylococcus spp. were recovered from two nozzle surfaces and three spray water; of these, S. epidermidis was found from two nozzle surfaces and one spray water. S. aureus was not isolated. Among non-glucose-fermenting rods (NFR), Acinetobacter johnsonii were isolated from 17 nozzle surfaces and 10 spray water and Stenotrophomonas maltophilia were isolated from three nozzle surfaces and six spray water, although no isolates were shown to be multi-drug resistant or MBL producer. Sphingomonas spp. were recovered from 32 nozzle surfaces (one S. paucimobilis was included) and 56 spray water. Of other Gram-negative bacteria, Pseudomonas spp. were isolated from 11 nozzle surfaces and 17 spray water, but P. aeruginosa was not included. Bacillus spp. were the most frequently isolated (43 toilets) Gram-positive bacteria, although possible pathogenic Bacillus spp., such as B. anthracis and B. cereus, were not detected. Among Candida spp., C. albicance was not isolated.
Isolates . | No. of samples (%) (N = 192) . | Isolated from . | No. of samples . | |
---|---|---|---|---|
Nozzle surface . | Spray water . | |||
E. coli | 8 (4.2) | + | + | 1 |
+ | – | 4 (1: ESBL producer) | ||
– | + | 3 (1: ESBL producer) | ||
Klebsiella spp.a | 3 (1.6) | + | – | 1 |
– | + | 2 | ||
Enterococcus spp.b | 7 (3.6) | + | – | 7 |
Staphylococcus spp.c | 5 (2.6) | + | – | 2 |
– | + | 3 | ||
Acinetobacter spp. | 24 (12.5) | + | + | 3 |
+ | – | 14 | ||
– | + | 7 | ||
Stenotrophomonas maltophylia | 8 (4.2) | + | + | 1 |
+ | – | 2 | ||
– | + | 5 | ||
Other NFR | 174 (90.6) | + | + | 127 |
+ | – | 13 | ||
– | + | 34 | ||
Sphingomonas spp.d | 71 (37.0) | + | + | 17 |
+ | – | 15 | ||
– | + | 39 | ||
Other GNR | 115 (59.9) | + | + | 27 |
+ | – | 34 | ||
– | + | 54 | ||
Other GPR | 83 (43.2) | + | + | 7 |
+ | – | 55 | ||
– | + | 21 | ||
Candida spp. | 13 (6.8) | + | + | 1 |
+ | – | 11 | ||
– | + | 1 |
Isolates . | No. of samples (%) (N = 192) . | Isolated from . | No. of samples . | |
---|---|---|---|---|
Nozzle surface . | Spray water . | |||
E. coli | 8 (4.2) | + | + | 1 |
+ | – | 4 (1: ESBL producer) | ||
– | + | 3 (1: ESBL producer) | ||
Klebsiella spp.a | 3 (1.6) | + | – | 1 |
– | + | 2 | ||
Enterococcus spp.b | 7 (3.6) | + | – | 7 |
Staphylococcus spp.c | 5 (2.6) | + | – | 2 |
– | + | 3 | ||
Acinetobacter spp. | 24 (12.5) | + | + | 3 |
+ | – | 14 | ||
– | + | 7 | ||
Stenotrophomonas maltophylia | 8 (4.2) | + | + | 1 |
+ | – | 2 | ||
– | + | 5 | ||
Other NFR | 174 (90.6) | + | + | 127 |
+ | – | 13 | ||
– | + | 34 | ||
Sphingomonas spp.d | 71 (37.0) | + | + | 17 |
+ | – | 15 | ||
– | + | 39 | ||
Other GNR | 115 (59.9) | + | + | 27 |
+ | – | 34 | ||
– | + | 54 | ||
Other GPR | 83 (43.2) | + | + | 7 |
+ | – | 55 | ||
– | + | 21 | ||
Candida spp. | 13 (6.8) | + | + | 1 |
+ | – | 11 | ||
– | + | 1 |
NFR, non-glucose-fermenting rods; GNR, Gram-negative rods; GPR, Gram-positive rods.
ESBL, extended-spectrum β-lactamase.
aThree E. faecalis (nozzle) were included.
bOne K. pneumoniae (nozzle) and two K. oxytoca (spray water) were included.
cThree S. epidermidis (two from nozzle and one from spray water) were included.
dOne S. paucimobilis (nozzle) was included.
The pattern of bacterial colonization was not significantly different between the toilets scrubbed every day and every week (Table 3). When the incidence of bacterial colonization with 104 or more recovered from the toilets sampled was compared, the incidence recovered from the nozzle surface was significantly greater in the toilets scrubbed every week than in those done every day. However, the incidence recovered from the spray water was not significantly different between the groups. Fecal indicator bacteria showing the colonization with 104 or more were recovered from the nozzle surface in the toilets scrubbed every day (E. coli and K. oxytoca), and those scrubbed every week (E. coli and Enterococcus faecalis). Although fecal indicator bacteria with thin colonies were isolated from the spray water in the toilets scrubbed either every day or every week, those having the colonization with 104 or more were not isolated (Table 4).
Water-jet nozzle contamination . | Spray water contamination . | No (%) of toilets scrubbed . | P-value . | |
---|---|---|---|---|
every day (n = 137) . | every week (n = 55) . | |||
+ | + | 117 (85.4) | 44 (80.0) | 0.97 |
+ | − | 4 (2.9) | 2 (3.6) | |
− | + | 13 (9.5) | 7 (12.7) | |
− | − | 3 (2.2) | 2 (3.6) |
Water-jet nozzle contamination . | Spray water contamination . | No (%) of toilets scrubbed . | P-value . | |
---|---|---|---|---|
every day (n = 137) . | every week (n = 55) . | |||
+ | + | 117 (85.4) | 44 (80.0) | 0.97 |
+ | − | 4 (2.9) | 2 (3.6) | |
− | + | 13 (9.5) | 7 (12.7) | |
− | − | 3 (2.2) | 2 (3.6) |
+, positive for bacteria; −, negative for bacteria.
. | Total (n = 192) . | Toilets scrubbed . | P-value . | |
---|---|---|---|---|
every day (n = 137) . | every week (n = 55) . | |||
Nozzle surface | 39 (20.3) | 21 (15.3)a | 18 (32.7)b | 0.00067 |
Spray water | 15 (7.8) | 14 (10.2) | 1 (1.8) | 0.096 |
. | Total (n = 192) . | Toilets scrubbed . | P-value . | |
---|---|---|---|---|
every day (n = 137) . | every week (n = 55) . | |||
Nozzle surface | 39 (20.3) | 21 (15.3)a | 18 (32.7)b | 0.00067 |
Spray water | 15 (7.8) | 14 (10.2) | 1 (1.8) | 0.096 |
Parentheses, percentage.
aE. coli and K. oxytoca, and bE. coli and E. faecalis were found as fecal indicator bacteria.
The pattern of bacterial colonization was not significantly different between the toilets for men only and those for women only. Also, the incidence of bacterial colonization with 104 or more recovered from the nozzle surface and the spray water sampled was not significantly different between the toilets for men only and those for women only (data not shown).
DISCUSSION
In this study, we surveyed the 119 bidet toilets installed at a hospital and found that the nozzle surface of 87% and the spray water of 94% were contaminated. In addition, we found that the incidence of greater contamination of the spray water was not significantly different between the toilets scrubbed every day and every week.
Fecal indicator bacteria such as Enterobacteriaceae, including E. coli, Klebsiella spp., and Enterococcus spp., were isolated in this study. The nozzle surface can become contaminated with feces, because users wash the anus after defecation. When feces contaminate the nozzle surface or the region around the hole from which the spray water exists, fecal indicator bacteria can be detected in the spray water. Antimicrobial-resistant bacteria were observed in two of the 192 bidet toilets (1.0%), one recovered from the nozzle surface and the other from the spray water, and both were the ESBL-producing E. coli. The World Health Organization has recognized the importance of studying the emergence and determinants of acquired antimicrobial resistance and the need to devise appropriate strategies for their control (World Health Organization 2018). In particular, the ESBL-producing E. coli are emerging worldwide (Lu et al. 2012) and may significantly affect the course and outcomes of infection, both in the community and in the hospital. The increased incidence of urinary tract infection due to ESBL-producing E. coli has been reported previously (Lu et al. 2012; Picozzi et al. 2013). An earlier report from Japan described an outbreak of an MBL-producing P. aeruginosa in a hospital hematology ward that was traced to the contamination of the nozzle of six bidet toilets. The study concluded that the exposure of immune-compromised patients to the contaminated nozzle led to clonal spread within the ward. The risk associated with the use of bidet toilets in immune-compromised patients should be understood (Hayashi et al. 2015).
NFR can be a major problem in the clinical environment, being a common cause of nosocomial infections. A. johnsonii and S. maltophilia were most frequently recovered bacteria in this study. NFR can form a viable biofilm matrix over an extended period (Capelletti & Moraes 2016). NFR in the spray water showed a marked increasing trend, rising to levels more than 100 times higher than those in the tap water. This suggests that NFR stay and biofilms form at higher rates in the water tanks and internal tubing of bidet toilets than in the tap water pipes. Iyo et al. (2016) reported that this was caused by the decreased level of residual chlorine in the water tank due to heating and remaining stagnant for a long period. As A. johnsonii and S. maltophilia may cause opportunistic infection in immunocompromised patients (Seifert et al. 1993; Muder et al. 1996; Calza et al. 2003; Rodrígues et al. 2014), the use of bidet toilets in this patient population must be a part of hospital risk management. Sphingomonas spp. are Gram-negative bacilli and found in multiple environments. Most of Sphingomonas spp. do not play a role in human disease, but some of those, especially S. paucimobilis, may cause nosocomial infection (Ryan & Adley 2010). In this study, S. paucimobilis were recovered from not only the nozzle surface of one bidet toilet but also the tap water of the other toilets in an inpatient ward. Of other Gram-negative bacteria, Pseudomonas spp. were isolated from bidet toilets, but P. aeruginosa were not recovered.
Staphylococcus spp., including S. epidermidis, were also isolated from bidet toilets in this study. When water was sprayed on the perineal skin, the nozzle surface or the region around the hole can be contaminated by the exfoliated epithelium with S. epidermidis.
In this study, the incidence of either nozzle surface or spray water contamination was not significantly different between toilets scrubbed every day and every week. However, when the frequency of bacterial colonization with 104 CFU or more recovered from the toilets sampled was compared, the frequency recovered from the nozzle surface was significantly greater in the toilets scrubbed every week than those done every day. It may be natural that considerable numbers of bacteria come from either feces or spray water existed on the nozzle surface which had not been scrubbed for the previous six days. On the other hand, the frequency recovered from the spray water was not significantly different between the toilets scrubbed every day and every week. Bidet toilets are equipped with a mechanism that cleans the nozzle and internal tubing of bidet toilet seats before and after use. Considering the low frequency of fecal indicator bacteria recovered from bidet toilets or the low frequency of greater bacterial contamination of the spray water, it appears that the equipped cleaning function of the nozzle was generally working properly.
It is interesting to observe the pattern of bacterial colonization of bidet toilets closely, because spray water was contaminated, while the nozzle surface was not contaminated in 20 of 192 toilets. The mechanism is uncertain, but this pattern may be possible if bidet toilets had not been used since the nozzle surface was scrubbed previously. The nozzle surface was sampled prior to spray water actually and was not contaminated by spray water.
This study had several limitations. First, this was a cross-sectional study and was not able to confirm the continued bacterial contamination of bidet toilets. Second, samples were taken from lavatory facilities in a rural district hospital, and this limits its generalizability to the findings in other hospitals. Third, the number of people who had used each unit since the bidet toilets were scrubbed previously is uncertain.
CONCLUSIONS
The nozzle surface and the spray water in the bidet toilets were contaminated with a wide range of bacteria, which may be a potential vehicle for infection. Because the interval of scrubbing the toilets, including the nozzle surface, did not have an influence on the contamination of spray water, and possible infectious NFR bacteria were isolated from the spray water, self-cleaning mechanisms of spray water or structural changes should be developed to prevent patients' healthcare-associated infections.
ACKNOWLEDGEMENTS
The authors thank Tomo Yamada, Kouhei Hashimoto, Toshiya Hidaka, Haruka Nagano, and Hayato Abe for collecting the samples. The authors thank Dr. Naoto Hosokawa for reviewing the manuscript critically. We thank Yuko Tsunoda for her assistance with the statistical analysis.
DISCLOSURE
The authors declare no conflicts of interest.