Table 4

Design capacities and costs of the objects

Solution #1Solution #2
PVCconst(BR)PVCop(BR)Capacitya (MCM/Season)PVCconst(BR)PVCop(BR)Capacitya (MCM/Season)
Reservoir 44.170 2.650 9.293 49.092 2.946 12.813 
Reservoir to demand area 0.0 0.0 0.0 17.133 0.007 4.853 
Reservoir to artificial recharge area 0.0 0.0 0.0 0.0 0.0 0.0 
Aquifer to reservoir 0.0 0.0 0.0 0.0 0.0 0.0 
River to demand area 20.484 5.172 9.357 1.05 0.337 0.402 
River to artificial recharge area 7.656 0.838 6.046 2.627 0.564 2.024 
Pumping wells – 1.629 N/A – 1.41 – 
Recharge wells – 2.095 N/A – 1.283 – 
Sum 72.310 12.384  69.902 6.547  
 84.694  76.449    
Solution #1Solution #2
PVCconst(BR)PVCop(BR)Capacitya (MCM/Season)PVCconst(BR)PVCop(BR)Capacitya (MCM/Season)
Reservoir 44.170 2.650 9.293 49.092 2.946 12.813 
Reservoir to demand area 0.0 0.0 0.0 17.133 0.007 4.853 
Reservoir to artificial recharge area 0.0 0.0 0.0 0.0 0.0 0.0 
Aquifer to reservoir 0.0 0.0 0.0 0.0 0.0 0.0 
River to demand area 20.484 5.172 9.357 1.05 0.337 0.402 
River to artificial recharge area 7.656 0.838 6.046 2.627 0.564 2.024 
Pumping wells – 1.629 N/A – 1.41 – 
Recharge wells – 2.095 N/A – 1.283 – 
Sum 72.310 12.384  69.902 6.547  
 84.694  76.449    

aReservoir capacity is in MCM.