Summary statistics for the experimental filter physical carbon content analysis, optical analyses, flowrate tests, and efficacy results in terms of log reduction values are given in Table 1.

Table 1

Summary of experimental filter testing

GroupStatisticCarbon content (%)Visual median tone
Flowrate (mL)
LRV
HiROXLeicaInitialFinal
Oxidizing Mean 0.0284 172 190 44 29 3.66 
Std dev. 0.0064 17.7 3.2 5.8 4.9 0.48 
CV 0.224 0.103 0.017 0.131 0.167 0.131 
Mid-range Mean 0.216 110 92 49 29 4.09 
Std dev. 0.252 40.8 49.0 5.9 7.7 0.41 
CV 1.166 0.370 0.533 0.121 0.260 0.101 
Reducing Mean 1.423 57 39 63 35 2.84 
Std dev. 0.274 10.9 11.4 5.2 8.1 0.83 
CV 0.193 0.190 0.290 0.083 0.234 0.294 
Overall Mean 0.556 113 107 52 31 3.52 
Std dev. 0.667 54.1 69.9 9.6 7.1 0.79 
CV 1.200 0.479 0.652 0.185 0.228 0.225 
GroupStatisticCarbon content (%)Visual median tone
Flowrate (mL)
LRV
HiROXLeicaInitialFinal
Oxidizing Mean 0.0284 172 190 44 29 3.66 
Std dev. 0.0064 17.7 3.2 5.8 4.9 0.48 
CV 0.224 0.103 0.017 0.131 0.167 0.131 
Mid-range Mean 0.216 110 92 49 29 4.09 
Std dev. 0.252 40.8 49.0 5.9 7.7 0.41 
CV 1.166 0.370 0.533 0.121 0.260 0.101 
Reducing Mean 1.423 57 39 63 35 2.84 
Std dev. 0.274 10.9 11.4 5.2 8.1 0.83 
CV 0.193 0.190 0.290 0.083 0.234 0.294 
Overall Mean 0.556 113 107 52 31 3.52 
Std dev. 0.667 54.1 69.9 9.6 7.1 0.79 
CV 1.200 0.479 0.652 0.185 0.228 0.225 

Std dev., standard deviation; CV, coefficient of variation.