Skip to Main Content

In Table 5, the specification and location of protection devices related to some Pareto solutions that are shown in Figure 8 are presented.

Table 5

The specification of some of the protection plans present in Pareto solutions

Solution#Air-inlet valves (location and type)Air-chambers (location and type)F1 cost (1,000*$)F2 (serviceability factor)
4(A),8(A),10(A),15(A),33(A),47(A),51(A),56(A),61(A) 27(A), 49(A) 173 0.906 
4(A),10(A),15(A),29(A),33(A),47(A),56(A),61(A) 2(B), 27(A),49(B) 311 0.642 
4(A),14(A),33(A),50(A),56(A) 2(B),8(A),27(B),49(A) 345 0.582 
4(A),10(A),14(A),56(A) 2(B),27(B),32(A),49(B) 383 0.265 
4(A),14(A),56(A) 2(B),27(B),32(B),49(B) 421 0.196 
Solution#Air-inlet valves (location and type)Air-chambers (location and type)F1 cost (1,000*$)F2 (serviceability factor)
4(A),8(A),10(A),15(A),33(A),47(A),51(A),56(A),61(A) 27(A), 49(A) 173 0.906 
4(A),10(A),15(A),29(A),33(A),47(A),56(A),61(A) 2(B), 27(A),49(B) 311 0.642 
4(A),14(A),33(A),50(A),56(A) 2(B),8(A),27(B),49(A) 345 0.582 
4(A),10(A),14(A),56(A) 2(B),27(B),32(A),49(B) 383 0.265 
4(A),14(A),56(A) 2(B),27(B),32(B),49(B) 421 0.196 