p-factor, r-factor, coefficient of determination (R2) and NS are calculated for performance evaluation of SWAT. In discharge calibration, 67% of measured data were bracketed by the 95PPU, whereas for sediment calibration, 56% of measured data fell in the 95PPU band (Table 4).
Results of calibration and uncertainty analysis in SUFI-2
. | Runoff . | Sediment . | ||
---|---|---|---|---|
Criteria . | Calibration . | Validation . | Calibration . | Validation . |
NS | 0.77 | 0.80 | 0.61 | 0.64 |
R2 | 0.82 | 0.85 | 0.61 | 0.66 |
r-factor | 0.76 | 0.73 | 0.85 | 0.81 |
p-factor | 0.64 | 0.67 | 0.52 | 0.56 |
. | Runoff . | Sediment . | ||
---|---|---|---|---|
Criteria . | Calibration . | Validation . | Calibration . | Validation . |
NS | 0.77 | 0.80 | 0.61 | 0.64 |
R2 | 0.82 | 0.85 | 0.61 | 0.66 |
r-factor | 0.76 | 0.73 | 0.85 | 0.81 |
p-factor | 0.64 | 0.67 | 0.52 | 0.56 |