Skip to Main Content

pH is a key parameter in oxidation processes. In this context, its effect in both wastewater treatment systems was compared. Table 2 shows TPh and COD removal after 120 min of catalytic ozonation (20 gO3/Nm3; 1 gcat/L) and Fenton's peroxidation ([H2O2] = 35 mM; 40 gcat/L) at different medium pH values ranging from 3 to 7.

Table 2

TPh and COD removal percentage after 120 min of catalytic ozonation and heterogeneous Fenton's process over ZVI for different medium pH values. Ozonation (20 gO3/Nm3, 1 gcat/L) and Fenton's ([H2O2] = 35 mM, 40 gcat/L)

pHOzonation
Fenton
TPh (%)COD (%)mgCODRemoved/molO3TPh (%)COD (%)mgCODRemoved/molH2O2
98 61 14,774 92 54 18,684 
90 50 12,110 64 16 5,536 
100 50 12,110 64 2,768 
pHOzonation
Fenton
TPh (%)COD (%)mgCODRemoved/molO3TPh (%)COD (%)mgCODRemoved/molH2O2
98 61 14,774 92 54 18,684 
90 50 12,110 64 16 5,536 
100 50 12,110 64 2,768 