Statistics of calibration and verification test results
Calibration . | Verification . | ||||||
---|---|---|---|---|---|---|---|
Time span . | R . | R2 . | Time span . | r . | RE . | CE . | ST . |
1969–1989 | 0.71** | 0.50 | 1990–2013 | 0.64** | 0.40 | 0.41 | 16+/5−* |
1990–2013 | 0.56* | 0.31 | 1969–1989 | 0.71** | 0.36 | 0.35 | 17+/5−* |
1969–2013 | 0.62** | 0.38 |
Calibration . | Verification . | ||||||
---|---|---|---|---|---|---|---|
Time span . | R . | R2 . | Time span . | r . | RE . | CE . | ST . |
1969–1989 | 0.71** | 0.50 | 1990–2013 | 0.64** | 0.40 | 0.41 | 16+/5−* |
1990–2013 | 0.56* | 0.31 | 1969–1989 | 0.71** | 0.36 | 0.35 | 17+/5−* |
1969–2013 | 0.62** | 0.38 |
r, Pearson's correlation coefficient; R2, explained variance; RE, reduction of error; CE, coefficient of efficiency; ST, sign test.
*Denotes significance at p(a) < 0.05.