Calculated design parameters using Thomas and hybrid models for dynamic adsorption of Cd(II) ions by OBA/nZVI
Flow rate (mL min–1) . | Bed depth (cm) . | Cd(II) concentration (mg L–1) . | Results of design parameter . | ||||
---|---|---|---|---|---|---|---|
qads (mg g–1) . | kTh (mL min–1 mg–1) . | ||||||
Experimental . | Thomas model . | Hybrid model . | Thomas model . | Hybrid model . | |||
1 | 8 | 50 | 4.64 | 4.86 | 4.69 | 0.72 | 0.68 |
1 | 8 | 150 | 3.52 | 3.81 | 3.47 | 1.19 | 1.08 |
10 | 8 | 50 | 4.04 | 4.62 | 3.98 | 1.05 | 0.79 |
10 | 8 | 150 | 3.03 | 4.02 | 2.98 | 1.56 | 1.42 |
1 | 16 | 50 | 5.24 | 5.39 | 5.31 | 0.24 | 0.21 |
1 | 16 | 150 | 3.96 | 4.18 | 3.85 | 0.47 | 0.42 |
10 | 16 | 50 | 4.52 | 4.94 | 4.41 | 0.43 | 0.36 |
10 | 16 | 150 | 3.32 | 4.34 | 3.41 | 0.61 | 0.54 |
Flow rate (mL min–1) . | Bed depth (cm) . | Cd(II) concentration (mg L–1) . | Results of design parameter . | ||||
---|---|---|---|---|---|---|---|
qads (mg g–1) . | kTh (mL min–1 mg–1) . | ||||||
Experimental . | Thomas model . | Hybrid model . | Thomas model . | Hybrid model . | |||
1 | 8 | 50 | 4.64 | 4.86 | 4.69 | 0.72 | 0.68 |
1 | 8 | 150 | 3.52 | 3.81 | 3.47 | 1.19 | 1.08 |
10 | 8 | 50 | 4.04 | 4.62 | 3.98 | 1.05 | 0.79 |
10 | 8 | 150 | 3.03 | 4.02 | 2.98 | 1.56 | 1.42 |
1 | 16 | 50 | 5.24 | 5.39 | 5.31 | 0.24 | 0.21 |
1 | 16 | 150 | 3.96 | 4.18 | 3.85 | 0.47 | 0.42 |
10 | 16 | 50 | 4.52 | 4.94 | 4.41 | 0.43 | 0.36 |
10 | 16 | 150 | 3.32 | 4.34 | 3.41 | 0.61 | 0.54 |