Table 3

Leaching of Cu and Ag determined after 24 h of contact with A. baumannii isolates in diluted nutrient media at 22 °C

c (mg L−1)12481632641282565121,024
CuNZ Mean <0.02 <0.02 <0.02 0.041 0.119 0.247 0.357 0.456 0.701 1.090 1.291 
±SD – – – 0.010 0.043 0.124 0.089 0.064 0.052 0.050 0.190 
– – – 32 46 48 34 22 17 13 
AgNZ mean <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 0.024 0.040 0.076 0.145 0.223 
±SD – – – – – – 0.011 0.018 0.018 0.021 0.038 
– – – – – – 0.9 0.8 0.8 0.6 
c (mg L−1)12481632641282565121,024
CuNZ Mean <0.02 <0.02 <0.02 0.041 0.119 0.247 0.357 0.456 0.701 1.090 1.291 
±SD – – – 0.010 0.043 0.124 0.089 0.064 0.052 0.050 0.190 
– – – 32 46 48 34 22 17 13 
AgNZ mean <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 0.024 0.040 0.076 0.145 0.223 
±SD – – – – – – 0.011 0.018 0.018 0.021 0.038 
– – – – – – 0.9 0.8 0.8 0.6 

The c (mg L−1) is the concentration of metal-exchanged-zeolite in the experimental vial and (%) is the percentage of leached metal from the total metal load on the zeolite; c0 (A. baumannii) = 105 CFU ml−1. The value of <0.02 mg L−1 designates measurement below the detection limit.

SD, standard deviation.

Close Modal