Table 3

Relative values of grab sampling results for different types of contaminant expressed as RBx values. Clean water measurements are shown as raw values (RBx = 1). FCM-TCC – total cell count, ATP – total ATP

ContaminantECTOCpHTORPTurbidityFCM-TCCATP
μS/cmmg/l°CmVNTUcells/mlRLU
Clean water 627 7.57 7.29 14.0 221.1 1.27 460,668 31,127 
Relative values of the parameters against the baseline (RBx) – dimensionless 
River water 0.99 1.17 1.00 0.98 1.02 1.82 1.19 1.29 
Groundwater 1.11 1.21 0.99 0.98 0.99 3.37 1.06 0.92 
Wastewater 1.07 1.67 0.99 1.00 0.70 6.33 13.36 53.57 
ContaminantECTOCpHTORPTurbidityFCM-TCCATP
μS/cmmg/l°CmVNTUcells/mlRLU
Clean water 627 7.57 7.29 14.0 221.1 1.27 460,668 31,127 
Relative values of the parameters against the baseline (RBx) – dimensionless 
River water 0.99 1.17 1.00 0.98 1.02 1.82 1.19 1.29 
Groundwater 1.11 1.21 0.99 0.98 0.99 3.37 1.06 0.92 
Wastewater 1.07 1.67 0.99 1.00 0.70 6.33 13.36 53.57 