Leakage rate (L/s) for different load condition
Demand multiplier (k) . | Initial leakage rate (L/s) . | After using variable speed pump is used (L/s) . |
---|---|---|
0.7 | 316.085 | 244.05 |
0.8 | 301.04 | 241.77 |
0.9 | 284.15 | |
1 | 266.2 | |
1.1 | 245.28 | |
1.2 | Pressure deficiency at Junc 3 | 258.003 |
1.3 | Pressure deficiency at Junc 3 | 248.45 |
Demand multiplier (k) . | Initial leakage rate (L/s) . | After using variable speed pump is used (L/s) . |
---|---|---|
0.7 | 316.085 | 244.05 |
0.8 | 301.04 | 241.77 |
0.9 | 284.15 | |
1 | 266.2 | |
1.1 | 245.28 | |
1.2 | Pressure deficiency at Junc 3 | 258.003 |
1.3 | Pressure deficiency at Junc 3 | 248.45 |