Summary of simulated scenarios for comparing performance of DO control, ABAC, and ABAC-SRT
Scenario . | Airflow control . | DO control . | NHx-N control . | MLSS control . | SRT control . | Supervisory control . |
---|---|---|---|---|---|---|
Case 1 | - Airflow set point provided by DO controller for each zone | - DO set point of 2 mg/L in all zones | - Not used | - MLSS set point = 2,000 mg/L - WAS flow rate bounded between 100 and 3,500 m3/d | - Not used | - Not used |
Case 2 | - Airflow set point provided by DO controller for each zone | - DO set point provided by NHx-N controller - Airflow set point bounded between minimum airflow for mixing and maximum airflow per diffuser | - NHx-N set point = 1 mg/L - DO set point bounded between 0.5 and 2 mg/L | - MLSS set point = 2,000 mg/L - WAS flow rate bounded between 100 and 3,500 m3/d | - Not used | - Not used |
Case 3 | - Airflow set point provided by DO controller for each zone | - DO set point provided by NHx-N controller - Airflow set point bounded between minimum airflow for mixing and maximum airflow per diffuser | - NHx-N set point = 1 mg/L - DO set point bounded between 0.5 and 2 mg/L | - MLSS set point provided by SRT controller - WAS flow rate bounded between 100 and 3,500 m3/d | - SRT set point provided by supervisory controller - MLSS set point bounded between 1,000 and 3,500 mg/L | - Average DO set point of 1 mg/L - SRT set point bounded between 3 and 20 days |
Scenario . | Airflow control . | DO control . | NHx-N control . | MLSS control . | SRT control . | Supervisory control . |
---|---|---|---|---|---|---|
Case 1 | - Airflow set point provided by DO controller for each zone | - DO set point of 2 mg/L in all zones | - Not used | - MLSS set point = 2,000 mg/L - WAS flow rate bounded between 100 and 3,500 m3/d | - Not used | - Not used |
Case 2 | - Airflow set point provided by DO controller for each zone | - DO set point provided by NHx-N controller - Airflow set point bounded between minimum airflow for mixing and maximum airflow per diffuser | - NHx-N set point = 1 mg/L - DO set point bounded between 0.5 and 2 mg/L | - MLSS set point = 2,000 mg/L - WAS flow rate bounded between 100 and 3,500 m3/d | - Not used | - Not used |
Case 3 | - Airflow set point provided by DO controller for each zone | - DO set point provided by NHx-N controller - Airflow set point bounded between minimum airflow for mixing and maximum airflow per diffuser | - NHx-N set point = 1 mg/L - DO set point bounded between 0.5 and 2 mg/L | - MLSS set point provided by SRT controller - WAS flow rate bounded between 100 and 3,500 m3/d | - SRT set point provided by supervisory controller - MLSS set point bounded between 1,000 and 3,500 mg/L | - Average DO set point of 1 mg/L - SRT set point bounded between 3 and 20 days |