Skip to Main Content
Table 2

Factors, levels and date of Box-Behnken design

VariablesCodeLevel of factors
− 101
Temperature (oC) X1 35 40 45  
Contact time (h) X2 10 11  
Initial pH X3 5.5  
Adsorbent dosage (mg/L) X4 300 350 400  
RunCoded levels
Adsorption rate (%)
X1X2X3X4
35 10 5.5 400 89.33 
45 5.5 350 92.76 
40 5.5 400 93.24 
40 10 5.5 350 93.33 
40 10 6.0 300 84.43 
40 5.0 350 90.71 
40 11 5.5 300 87.46 
45 10 5.5 300 87.85 
45 10 5.0 350 91.59 
10 35 5.5 350 87.74 
11 40 10 6.0 400 89.47 
12 40 10 5.0 300 85.23 
13 40 11 5.5 400 93.78 
14 40 11 5.0 350 93.93 
15 35 11 5.5 350 90.26 
16 40 10 5.5 350 92.13 
17 45 10 5.5 400 95.74 
18 45 11 5.5 350 95.42 
19 40 10 5.5 350 92.57 
20 35 10 5.5 300 85.87 
21 35 10 5.0 350 89.62 
22 40 10 5.0 400 91.31 
23 40 10 5.5 350 92.23 
24 35 10 6.0 350 86.40 
25 40 10 5.5 350 92.63 
26 40 5.5 300 86.54 
27 40 11 6.0 350 89.27 
28 45 10 6.0 350 90.25 
29 40 6.0 350 89.47 
VariablesCodeLevel of factors
− 101
Temperature (oC) X1 35 40 45  
Contact time (h) X2 10 11  
Initial pH X3 5.5  
Adsorbent dosage (mg/L) X4 300 350 400  
RunCoded levels
Adsorption rate (%)
X1X2X3X4
35 10 5.5 400 89.33 
45 5.5 350 92.76 
40 5.5 400 93.24 
40 10 5.5 350 93.33 
40 10 6.0 300 84.43 
40 5.0 350 90.71 
40 11 5.5 300 87.46 
45 10 5.5 300 87.85 
45 10 5.0 350 91.59 
10 35 5.5 350 87.74 
11 40 10 6.0 400 89.47 
12 40 10 5.0 300 85.23 
13 40 11 5.5 400 93.78 
14 40 11 5.0 350 93.93 
15 35 11 5.5 350 90.26 
16 40 10 5.5 350 92.13 
17 45 10 5.5 400 95.74 
18 45 11 5.5 350 95.42 
19 40 10 5.5 350 92.57 
20 35 10 5.5 300 85.87 
21 35 10 5.0 350 89.62 
22 40 10 5.0 400 91.31 
23 40 10 5.5 350 92.23 
24 35 10 6.0 350 86.40 
25 40 10 5.5 350 92.63 
26 40 5.5 300 86.54 
27 40 11 6.0 350 89.27 
28 45 10 6.0 350 90.25 
29 40 6.0 350 89.47 
Close Modal

or Create an Account

Close Modal
Close Modal