Table 1

Relevant properties of studied locations

PropertiesKovin-Dubovac drainage systemKljuč groundwater source
Aquifer composition Sandy and sandy gravel soils Sandy and gravelly soils 
Aquifer hydraulic conductivity (m s−10.5–7 × 10−3 7 × 10−3 (gravelly part)
10−5–10−4 (sandy soils) 
Aquifer thickness (m) 1.5–35 (with average value of 20) Around 20 
Overlying top layer hydraulic conductivity (m s−110−5 10−8–10−6 
Overlying top layer thickness (m) 4 (first drainage line) 3–5 
Redox potential (mV) 96 >350 
Dissolved oxygen concentration (mg L−10.06 5.77 
Groundwater condition Anoxic Oxic 
PropertiesKovin-Dubovac drainage systemKljuč groundwater source
Aquifer composition Sandy and sandy gravel soils Sandy and gravelly soils 
Aquifer hydraulic conductivity (m s−10.5–7 × 10−3 7 × 10−3 (gravelly part)
10−5–10−4 (sandy soils) 
Aquifer thickness (m) 1.5–35 (with average value of 20) Around 20 
Overlying top layer hydraulic conductivity (m s−110−5 10−8–10−6 
Overlying top layer thickness (m) 4 (first drainage line) 3–5 
Redox potential (mV) 96 >350 
Dissolved oxygen concentration (mg L−10.06 5.77 
Groundwater condition Anoxic Oxic 