Skip to Main Content
Table 6

Calculation of adsorption parameters

ParameterDesignationValueUnit
Filtration speed vf 19.730 m·hr−1 
Bed height h 0.700 
Column diameter d 0.044 
Bed area Ar 0.002 m2 
Flow Qt 0.030 m3·hr−1 
Material volume VR 1,060 dm3 
Volume of flow water VF 0.030 m3 
Bed volume BV 28.30 – 
Delay contact time EBCT 0.035 hr 
EBCT 2.129 min 
ParameterDesignationValueUnit
Filtration speed vf 19.730 m·hr−1 
Bed height h 0.700 
Column diameter d 0.044 
Bed area Ar 0.002 m2 
Flow Qt 0.030 m3·hr−1 
Material volume VR 1,060 dm3 
Volume of flow water VF 0.030 m3 
Bed volume BV 28.30 – 
Delay contact time EBCT 0.035 hr 
EBCT 2.129 min 