Different parameter levels and responses for each experiment in the Plackett–Burman design

RunFactors
AInitial COD (mg/L)CElectrical conductivity (μS/cm)Applied cell voltage (V)FUV lamp wavelength (nm)H2O2 concentration (mM)IResidence time (min)Initial pHy (COD removal efficiency) (%)
−1 562.5 −1 1,800 10 365 −1 15 55.85 
375 −1 1,800 20 365 15 71.20 
375 1,800 10 −1 365 10 59.73 
562.5 1,800 20 254 −1 10 67.29 
−1 375 −1 2,500 20 254 10 54.80 
562.5 −1 2,500 20 −1 365 −1 10 48.27 
375 2,500 10 254 −1 15 64.53 
−1 562.5 1,800 20 −1 254 15 74.99 
−1 562.5 2,500 10 365 10 73.10 
10 562.5 −1 2,500 10 −1 254 15 78.19 
11 −1 375 2,500 20 −1 365 −1 15 75.29 
12 −1 375 −1 1,800 10 −1 254 −1 10 67.02 
RunFactors
AInitial COD (mg/L)CElectrical conductivity (μS/cm)Applied cell voltage (V)FUV lamp wavelength (nm)H2O2 concentration (mM)IResidence time (min)Initial pHy (COD removal efficiency) (%)
−1 562.5 −1 1,800 10 365 −1 15 55.85 
375 −1 1,800 20 365 15 71.20 
375 1,800 10 −1 365 10 59.73 
562.5 1,800 20 254 −1 10 67.29 
−1 375 −1 2,500 20 254 10 54.80 
562.5 −1 2,500 20 −1 365 −1 10 48.27 
375 2,500 10 254 −1 15 64.53 
−1 562.5 1,800 20 −1 254 15 74.99 
−1 562.5 2,500 10 365 10 73.10 
10 562.5 −1 2,500 10 −1 254 15 78.19 
11 −1 375 2,500 20 −1 365 −1 15 75.29 
12 −1 375 −1 1,800 10 −1 254 −1 10 67.02 