Estimated and
values based on single pumping well tests in the lower region of the study area
Well No. . | W.T (m) . | Copper-Jacob . | Theis . | Mean . | K (m/day) . | |||
---|---|---|---|---|---|---|---|---|
![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |||
W11 | 2.73 | 294.60 | 1.473 | 291.50 | 1.450 | 293.05 | 1.462 | 95.060 |
W12 | 1.67 | 624.00 | 3.120 | 630.00 | 3.142 | 627.00 | 3.131 | 102.250 |
W13 | 4.13 | Low discharge | – | Low discharge | – | – | – | low |
W14 | 9.60 | Low discharge | – | Low discharge | – | – | – | low |
W15 | 5.32 | 712.06 | 3.560 | 714.10 | 3.668 | 713.08 | 3.614 | 270.100 |
W16 | 5.16 | 7.61 | 0.03805 | 7.50 | 0.0225 | 7.555 | 7.555 | 0.255 |
Well No. . | W.T (m) . | Copper-Jacob . | Theis . | Mean . | K (m/day) . | |||
---|---|---|---|---|---|---|---|---|
![]() | ![]() | ![]() | ![]() | ![]() | ![]() | |||
W11 | 2.73 | 294.60 | 1.473 | 291.50 | 1.450 | 293.05 | 1.462 | 95.060 |
W12 | 1.67 | 624.00 | 3.120 | 630.00 | 3.142 | 627.00 | 3.131 | 102.250 |
W13 | 4.13 | Low discharge | – | Low discharge | – | – | – | low |
W14 | 9.60 | Low discharge | – | Low discharge | – | – | – | low |
W15 | 5.32 | 712.06 | 3.560 | 714.10 | 3.668 | 713.08 | 3.614 | 270.100 |
W16 | 5.16 | 7.61 | 0.03805 | 7.50 | 0.0225 | 7.555 | 7.555 | 0.255 |