Table 1

Results of chemical and bacteriological analyses of rainwater in compliance with WHO (2004) and Cameroon (ANOR 2003) potable water standards

ParameterUnitRainwater results n = 10Standard deviationWHO Limits (2004) (≤)Cameroon potable water standard (ANOR 2003) (≤)
pH – 6.25 0.45 Between 6.5 and 8.5 Between 6.5 and 9 
Electrical Conductivity μS/cm 57.75 34,13 NA 1000 
Suspended Solids mg/l  NA NA 
Ca2+ mg/l 11.16 9,28 75 NA 
Mg2+ mg/l 0.39 0,22 30 50 
Na+ mg/l 0.19 0,04 200 150 
K+ mg/l 26.56 36,17 50 12 
Cl mg/l 15.34 16,65 250 NA 
F mg/l 0.05 0,04 1.5 0.7/l 
 mg/l 54.78 13,29 200 250 
 mg/l 0.01 0,01 NA 
Total Coliform Count CFU 100 25 
Feacal Coliform Count CFU 50 31 
ParameterUnitRainwater results n = 10Standard deviationWHO Limits (2004) (≤)Cameroon potable water standard (ANOR 2003) (≤)
pH – 6.25 0.45 Between 6.5 and 8.5 Between 6.5 and 9 
Electrical Conductivity μS/cm 57.75 34,13 NA 1000 
Suspended Solids mg/l  NA NA 
Ca2+ mg/l 11.16 9,28 75 NA 
Mg2+ mg/l 0.39 0,22 30 50 
Na+ mg/l 0.19 0,04 200 150 
K+ mg/l 26.56 36,17 50 12 
Cl mg/l 15.34 16,65 250 NA 
F mg/l 0.05 0,04 1.5 0.7/l 
 mg/l 54.78 13,29 200 250 
 mg/l 0.01 0,01 NA 
Total Coliform Count CFU 100 25 
Feacal Coliform Count CFU 50 31 

Note: NA: not applicable.