Table 2

The source and range of model variables and parameters that were used to evaluate the best fit parameters for first-order and zero-order decay rate and θ

Parameter/ variableSymbolValueUnitsSource
Number of tanks in series 7.8 unitless Tracer test evaluation 
Inlet nitrate concentration Ci 6.9–60.8 mg N L−1 Field measure 
Outlet nitrate concentration Co 1.1–33.5 mg N L−1 Field measure 
Mean hydraulic retention time  21–29 hr Table 1 
Temperature 5.3–22.9 °C Field measure 
Set temperature To 20 °C Conventional value 
Arrhenius theta θ 1.04–1.20 unitless Literature 
First-order decay rate k1 0.1–2.0 day−1 Literature 
Zero-order decay rate k0 0.5–20 g N m−3 day−1 Literature 
Parameter/ variableSymbolValueUnitsSource
Number of tanks in series 7.8 unitless Tracer test evaluation 
Inlet nitrate concentration Ci 6.9–60.8 mg N L−1 Field measure 
Outlet nitrate concentration Co 1.1–33.5 mg N L−1 Field measure 
Mean hydraulic retention time  21–29 hr Table 1 
Temperature 5.3–22.9 °C Field measure 
Set temperature To 20 °C Conventional value 
Arrhenius theta θ 1.04–1.20 unitless Literature 
First-order decay rate k1 0.1–2.0 day−1 Literature 
Zero-order decay rate k0 0.5–20 g N m−3 day−1 Literature 