The source and range of model variables and parameters that were used to evaluate the best fit parameters for first-order and zero-order decay rate and θ
Parameter/ variable . | Symbol . | Value . | Units . | Source . |
---|---|---|---|---|
Number of tanks in series | N | 7.8 | unitless | Tracer test evaluation |
Inlet nitrate concentration | Ci | 6.9–60.8 | mg N L−1 | Field measure |
Outlet nitrate concentration | Co | 1.1–33.5 | mg N L−1 | Field measure |
Mean hydraulic retention time | ![]() | 21–29 | hr | Table 1 |
Temperature | T | 5.3–22.9 | °C | Field measure |
Set temperature | To | 20 | °C | Conventional value |
Arrhenius theta | θ | 1.04–1.20 | unitless | Literature |
First-order decay rate | k1 | 0.1–2.0 | day−1 | Literature |
Zero-order decay rate | k0 | 0.5–20 | g N m−3 day−1 | Literature |
Parameter/ variable . | Symbol . | Value . | Units . | Source . |
---|---|---|---|---|
Number of tanks in series | N | 7.8 | unitless | Tracer test evaluation |
Inlet nitrate concentration | Ci | 6.9–60.8 | mg N L−1 | Field measure |
Outlet nitrate concentration | Co | 1.1–33.5 | mg N L−1 | Field measure |
Mean hydraulic retention time | ![]() | 21–29 | hr | Table 1 |
Temperature | T | 5.3–22.9 | °C | Field measure |
Set temperature | To | 20 | °C | Conventional value |
Arrhenius theta | θ | 1.04–1.20 | unitless | Literature |
First-order decay rate | k1 | 0.1–2.0 | day−1 | Literature |
Zero-order decay rate | k0 | 0.5–20 | g N m−3 day−1 | Literature |