The data presented in Table 2 are the results of the analyses carried out on the sludge generated. The results are expressed as mg per kg on a dry basis. Table 3 also reports land application reference values according to American (Title 40 of the Code of Federal Regulations, Part 503) and Brazilian (Resolution of CONAMA no.498 of 2020) guidelines. It is worth mentioning that these guidelines consider sewage sludge. Therefore, in the absence of reference for sludge produced in water treatment, we considered these ceiling values to contribute to a discussion about the viability of sludge from WTP using a tannin-based coagulant for land application.

Table 2

Average concentration of metals in mg·kg−1 for the sludge

MetalConcentration (mg·kg1)Reference values for land application (mg·Kg1)
USEPA 40 CFR Part 503 (US-EPA (1993))CONAMA 498/2020 (Brasil 2020)
Aluminum 1,371.62 ± 359.13 – – 
Beryllium <0.17 – – 
Boron 18.45 ± 4.54 – – 
Calcium 38.00 ± 92.77 – – 
Cobalt <1.37 – – 
Iron 1,142.23 ± 86.04 – – 
Lithium <0.07 – – 
Magnesium 49.67 ± 7.29 – – 
Manganese 17.36 ± 5.17 – – 
Phosphorus 17.03 ± 49.74 – – 
Potassium <86.86 – – 
Silicon 685.69 ± 47.56 – – 
Sodium <65.94 – – 
Strontium 1.64 ± 0.77 – – 
Titanium 69.50 ± 4.16 – – 
Vanadium 3.43 ± 0.32 – – 
Barium 4.57 ± 1.35 – 1,300a,b 
Cadmium <2.4 39 39a and 85b 
Chromium <4.49 – 1,000a and 3,000b 
Copper <3.22 1,500 1,500a and 4,300b 
Lead <34.61 300 – 
Molybdenum <19.66 – 50a and 75b 
Nickel <7.05 420 420a and 420b 
Zinc 6.69 ± 1.84 2,800 2,800a and 7,500b 
MetalConcentration (mg·kg1)Reference values for land application (mg·Kg1)
USEPA 40 CFR Part 503 (US-EPA (1993))CONAMA 498/2020 (Brasil 2020)
Aluminum 1,371.62 ± 359.13 – – 
Beryllium <0.17 – – 
Boron 18.45 ± 4.54 – – 
Calcium 38.00 ± 92.77 – – 
Cobalt <1.37 – – 
Iron 1,142.23 ± 86.04 – – 
Lithium <0.07 – – 
Magnesium 49.67 ± 7.29 – – 
Manganese 17.36 ± 5.17 – – 
Phosphorus 17.03 ± 49.74 – – 
Potassium <86.86 – – 
Silicon 685.69 ± 47.56 – – 
Sodium <65.94 – – 
Strontium 1.64 ± 0.77 – – 
Titanium 69.50 ± 4.16 – – 
Vanadium 3.43 ± 0.32 – – 
Barium 4.57 ± 1.35 – 1,300a,b 
Cadmium <2.4 39 39a and 85b 
Chromium <4.49 – 1,000a and 3,000b 
Copper <3.22 1,500 1,500a and 4,300b 
Lead <34.61 300 – 
Molybdenum <19.66 – 50a and 75b 
Nickel <7.05 420 420a and 420b 
Zinc 6.69 ± 1.84 2,800 2,800a and 7,500b 

The limit of detection was defined as 3 times of blank standard deviation.

asludge class A (<10³ Escherichia coli per gram of total solids).

bsludge class B (<106Escherichia coli per gram of total solids).

Table 3

Average aluminum, iron, and manganese concentration in raw water and after treatment

MetalRaw water (mg·L1)aTreated water (mg·L1)aAverage Removal
Aluminum 0.044 ± 0.007 0.003 ± 0.002 93.76% 
Iron 1.240 ± 0.038 0.033 ± 0.017 97.37% 
Manganese 0.112 ± 0.07 0.003 ± 0.002 97.54% 
MetalRaw water (mg·L1)aTreated water (mg·L1)aAverage Removal
Aluminum 0.044 ± 0.007 0.003 ± 0.002 93.76% 
Iron 1.240 ± 0.038 0.033 ± 0.017 97.37% 
Manganese 0.112 ± 0.07 0.003 ± 0.002 97.54% 

aStatistics based on n = 13 tests.