In total, 2,697,420 cubic mesh cells were used for solid and flow domains. The details of other indicators for mesh quality are presented in Table 1. Table 2 shows the summary of numerical methods used for the present models.
Cell size and mesh quality indicators
Mesh block . | Mesh direction . | Number of cells . | Cell size (m) . | Max. adjacent ratio . | Max. aspect ratio . |
---|---|---|---|---|---|
Single structured | x | 330 | 0.168 | 1 | 1 |
y | 120 | 0.168 | 1 | 1 | |
z | 67 | 0.168 | 1 | 1 | |
Total | 2,697,420 |
Mesh block . | Mesh direction . | Number of cells . | Cell size (m) . | Max. adjacent ratio . | Max. aspect ratio . |
---|---|---|---|---|---|
Single structured | x | 330 | 0.168 | 1 | 1 |
y | 120 | 0.168 | 1 | 1 | |
z | 67 | 0.168 | 1 | 1 | |
Total | 2,697,420 |
Summary of setup for numerical models
Sr. no. . | 3D modelling method . | Model setup . | Sr. no. . | 3D modelling method . | Model setup . |
---|---|---|---|---|---|
1 | Meshing | 3D structured cubic cell | 4 | Advection scheme | Explicit second order limited |
2 | Turbulence model | RANS RNG-k–![]() | 5 | Multiphase treatment | VOF with one fluid |
3 | Solid contours | Wall boundary | 6 | Free-surface tracking | Donor–acceptor method |
Sr. no. . | 3D modelling method . | Model setup . | Sr. no. . | 3D modelling method . | Model setup . |
---|---|---|---|---|---|
1 | Meshing | 3D structured cubic cell | 4 | Advection scheme | Explicit second order limited |
2 | Turbulence model | RANS RNG-k–![]() | 5 | Multiphase treatment | VOF with one fluid |
3 | Solid contours | Wall boundary | 6 | Free-surface tracking | Donor–acceptor method |