For the field operation, first, background SEC at 25 °C in μS of the borehole water was taken with a Heron temperature, level, and conductivity (TLC) metre logger. Metal weighted hose pipe injectors were inserted into the 100- and 50-m deep wells. After this NaCl was dissolved in a calculated volume of water, mixed thoroughly, and injected uniformly along the water columns in the wells (see injection parameters in Table 1) via the injector.

Table 1

Borehole and NaCl injection details

Well coordinates/terrainGround elevation (m.a.s.l.)Well depth/open section (m)Depth to water table (m)/Casing length (m)Borehole diameter (mm)Salt mass injected (g)/volume of water in well (L)
5°17′21.9″N 2°00′37.3″W/Hilly borehole 103 100 m, 45–100 mbgl 13, 45 140 1,000, 1,339 
5°17′58.00″N 2°00′08.04″W/Valley borehole 76 50 m, 10–50 mbgl 8, 10 140 608, 639 
Well coordinates/terrainGround elevation (m.a.s.l.)Well depth/open section (m)Depth to water table (m)/Casing length (m)Borehole diameter (mm)Salt mass injected (g)/volume of water in well (L)
5°17′21.9″N 2°00′37.3″W/Hilly borehole 103 100 m, 45–100 mbgl 13, 45 140 1,000, 1,339 
5°17′58.00″N 2°00′08.04″W/Valley borehole 76 50 m, 10–50 mbgl 8, 10 140 608, 639 