Skip to Main Content
Table 4

Source water physical and chemical characteristics, by source type

Source typeNumber of sourcesTurbidity (NTU)
pH
Conductivity (μmhos/cm)
MedianRangeMedianRangeMedianRange
Urban tap 26 1.70 (0.1–10.3) 7.4 (6.2–9.4) 135 (10–780) 
Rural tap 11 1.54 (0.0–4.62) 6.5 (4.8–9.0) 100 (50–610) 
Protected well 30 1.33 (0.0–87.1) 6.8 (5.0–8.7) 175 (10–1,130) 
Protected spring 18 0.31 (0.0–10.5) 6.2 (4.3–8.5) 180 (0–2,000) 
Rainwater 1.78 (–) 6.6 (–) 20 (–) 
Open water 45 11.5 (0.0–551) 7.1 (5.1–9.0) 130 (0–1,200) 
Open well 25 8.21 (0.69–136) 7.3 (4.1–8.9) 355 (0–1,110) 
Vendor 0.85 (0.0–1.7) 6.7 (6.1–7.3) 280 (120–440) 
Total 159 3.37 (0.0–551) 7.0 (4.1–9.4) 160 (0–2,000) 
Source typeNumber of sourcesTurbidity (NTU)
pH
Conductivity (μmhos/cm)
MedianRangeMedianRangeMedianRange
Urban tap 26 1.70 (0.1–10.3) 7.4 (6.2–9.4) 135 (10–780) 
Rural tap 11 1.54 (0.0–4.62) 6.5 (4.8–9.0) 100 (50–610) 
Protected well 30 1.33 (0.0–87.1) 6.8 (5.0–8.7) 175 (10–1,130) 
Protected spring 18 0.31 (0.0–10.5) 6.2 (4.3–8.5) 180 (0–2,000) 
Rainwater 1.78 (–) 6.6 (–) 20 (–) 
Open water 45 11.5 (0.0–551) 7.1 (5.1–9.0) 130 (0–1,200) 
Open well 25 8.21 (0.69–136) 7.3 (4.1–8.9) 355 (0–1,110) 
Vendor 0.85 (0.0–1.7) 6.7 (6.1–7.3) 280 (120–440) 
Total 159 3.37 (0.0–551) 7.0 (4.1–9.4) 160 (0–2,000) 