Small vertical-flow constructed wetland units comprising the first stage of the French system were studied in Brazil for the treatment of raw sewage. Planted and unplanted units and different feeding strategies were tested. In the first phase, hourly batches of a daily flow of 13 m3 d−1 were applied over three alternating units, resulting in an average hydraulic loading rate (HLR) on the full system of 0.15 m3 m−2 d−1. A second phase, aimed at reducing land requirements, kept the same daily flow and batch frequency, but used two alternating units, resulting in a HLR on the full system of 0.22 m3 m−2 d−1. Removal efficiencies were very good when the system operated with three units, with mean values of 82% for biochemical oxygen demand (BOD), 81% for chemical oxygen demand (COD), 85% for total suspended solids (TSS) and 59% for NH4+-N. With two units, the equivalent values were 74% for BOD, 59% for COD, 67% for TSS and 51% for NH4+-N. There were significant differences in the median removal efficiencies of COD and TSS. No significant differences were found between planted and unplanted units for most constituents. In both phases, the overall good performance and the simplicity of the system make this treatment process a very attractive alternative for developing countries.
Skip Nav Destination
Article navigation
Research Article|
July 07 2014
First stage of the French vertical flow constructed wetland system: experiments with the reduction of surface area and number of units
E. S. Manjate;
1Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Brazil
E-mail: [email protected]; [email protected]
Search for other works by this author on:
L. C. O. Lana;
L. C. O. Lana
1Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Brazil
Search for other works by this author on:
D. C. Moraes;
D. C. Moraes
1Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Brazil
Search for other works by this author on:
G. R. Vasconcellos;
G. R. Vasconcellos
1Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Brazil
Search for other works by this author on:
G. R. M. Maciel;
G. R. M. Maciel
1Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Brazil
Search for other works by this author on:
M. von Sperling
M. von Sperling
1Department of Sanitary and Environmental Engineering, Federal University of Minas Gerais, Brazil
Search for other works by this author on:
Journal of Water, Sanitation and Hygiene for Development (2015) 5 (1): 50–55.
Article history
Received:
December 16 2013
Accepted:
June 03 2014
Citation
E. S. Manjate, L. C. O. Lana, D. C. Moraes, G. R. Vasconcellos, G. R. M. Maciel, M. von Sperling; First stage of the French vertical flow constructed wetland system: experiments with the reduction of surface area and number of units. Journal of Water, Sanitation and Hygiene for Development 1 March 2015; 5 (1): 50–55. doi: https://doi.org/10.2166/washdev.2014.009
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00