In rapidly urbanising low-income towns and cities, there remains an absence of scientific evidence and regulatory structures to sustain the quality and quantity of groundwater used for low-cost water supplies and to reconcile this with continued use of the subsurface for low-cost sanitation. Here, we analyse the relationship between the density of on-site sanitation and shallow groundwater quality in the Thiaroye aquifer of Quaternary sands in Dakar, Senegal. On-site sanitation was mapped using object-oriented classification and visual interpretation of high-resolution, optical satellite images and ground-truthing surveys. Groundwater quality was assessed over a three-year period (2017–2019) from a network of 61 sources comprising boreholes, dug-wells, hand tubewells and piezometers. More than 253,000 on-site sanitation facilities are identified over an area of 520 km2 with densities ranging from 1 to 70 per hectare. A moderate, statistically significant linear relationship (r2 = 0.55, p « 0.01) is found between the density of on-site sanitation facilities and nitrate concentrations in sampled groundwater sources. Groundwater contamination beyond the WHO drinking-water guideline value (50 mg/L) occurs where densities of on-site sanitation facilities exceed 4 (±4) per hectare, a threshold commonly surpassed in peri-urban areas underlain by the Thiaroye aquifer of Dakar.

  • Here, we conduct the first city-scale analysis in sub-Saharan Africa of the relationship between the density of on-site sanitation (generally unimproved) and shallow groundwater quality.

  • These provisional results have important implications not only for urban planning in areas dominated by the use of on-site water and sanitation facilities, but also for other dense settlements such as refugee and IDP (internally displaced peoples) camps.

Groundwater is a climate-resilient source of freshwater in sub-Saharan Africa (Cuthbert et al. 2019), playing a vital role in sustaining improved access to safe water in pursuit of United Nations Sustainable Development Goal 6 – water and sanitation for all by 2030. The strategic importance of groundwater in urban areas lies additionally in: (1) its lower vulnerability to contamination relative to surface waters reducing treatment costs, and (2) its capacity for phased investment (Adelana & MacDonald 2008; Foster et al. 2018; Olago 2019). The last two decades have witnessed substantial growth in the use of groundwater in towns and cities across sub-Saharan Africa, both alone (e.g. Dodoma, Tanzania) and in conjunction with surface water (e.g. Cape Town, South Africa; Dar es Salaam, Tanzania) (Taylor et al. 2004a; Lapworth et al. 2017; Gaye & Tindimugaya 2019; Olivier & Xu 2019). The distributed nature of groundwater enables individuals to construct private, on-site groundwater sources (e.g. boreholes, shallow wells, and protected springs). The proportion of urban dwellers in sub-Saharan Africa served by piped water supplies has declined over the last three decades (Tucker et al. 2014; Foster & Chilton 2017), whereas the proportion of on-site sources or self-supply has risen considerably (Healy et al. 2018).

Increased use of the urban groundwater commons in sub-Saharan Africa is constrained quantitatively by competitive abstraction (Diouf 2012) and qualitatively by seawater intrusion in coastal aquifers (e.g. Diouf 2012; Comte et al. 2016) and use of the shallow subsurface to contain faecal waste through on-site sanitation (Kulabako et al. 2007; Taylor et al. 2009; Kiptum & Ndambuki 2012; Okotto et al. 2015; Nayebare et al. 2020; Sorensen et al. 2020). For the latter, the risk to groundwater quality derives from faecal effluent, rich in organic nitrogen (urea: CO (NH2)2), chloride, and pathogenic microorganisms, that drains from on-site sanitation (e.g. pit latrines, septic tanks) into the surrounding soil. Mineralisation of this organic nitrogen (i.e. nitrification) then produces substantial concentrations of nitrate in the leachate (e.g. Harman et al. 1996; Buss et al. 2005). In most cities in sub-Saharan Africa, conventional sewerage serves only a small proportion of the urban population so that on-site sanitation is the dominant form of provision (Morella et al. 2008; UNICEF and WHO 2015). Conjunctive use of the subsurface to provide a source of safe water and repository of faecal effluent requires careful management, supported by effective policies and informed by science (Olago 2019).

Research to date has focused on protecting groundwater sources from faecal contamination in African towns and cities, and is dominated by local-scale analyses evaluating setback (safe) distances between ‘source’, on-site sanitation facility, and ‘receptor’, an individual groundwater-fed waterpoint (e.g. ARGOSS 2001; Howard et al. 2003; DEW POINT and DFID 2007; Mbaka et al. 2017). Such approaches are better suited to rural or low-density settlements where individual sources and receptors can be readily identified. Far fewer studies (e.g. Wright et al. 2012; Templeton et al. 2015) have examined the relationship between the density of on-site facilities from multiple locations and groundwater quality sampled from multiple receptors. Templeton et al. (2015) used a numerical model to estimate the impact of faecal effluent from pit latrines on nitrate concentrations in shallow groundwater that was informed by observations from three cities in West Africa including Abidjan (Ivory Coast), Abomey-Calavi (Benin), and Dakar (Senegal). Wright et al. (2012) conducted ground-based mapping of pit latrines and shallow wells over an area of ∼4 km2 in Kisumu (Kenya) and found the number of pit latrines within a radius of 100 m correlated significantly (p= 0.004) with nitrate concentrations sampled from shallow wells.

Here, we conduct the first city-scale analysis in sub-Saharan Africa of the relationship between the density of on-site sanitation (generally unimproved) and shallow groundwater quality within an unconsolidated Quaternary sand aquifer in the Thiaroye area of Dakar (Senegal). To map the density of on-site sanitation facilities over an area of ∼520 km2, we apply an object-oriented classification and visual interpretation of high-resolution, optical satellite imagery (i.e. Quickbird, Geoeye, Orbview), supported by extensive ground-truthing surveys. The density of on-site sanitation facilities (generally unimproved) is then compared to observed concentrations of faecal contamination from solutes (nitrate) and bacteria (Escherichia coli) sampled from 61 shallow ground-water sources over three years (20172019) to assess their association (dependency). Key intended outcomes of this city-scale analysis include an improved understanding of the capacity of this unconsolidated sand aquifer to attenuate faecal effluent from on-site sanitation facilities and guidance concerning the carrying capacity of the aquifer to provide safe water and store faecal waste.

Study area

The study area lies within the Thiaroye shallow aquifer on the Cap Vert Peninsula (Figure 1) and extends from the head of the Dakar peninsula to Kayar Township (longitudes 17°25′ to 17°17′ W and latitudes 14°49′ to 14°43′ N). The peninsular climate of Cap Vert is semi-arid with a short rainy season, which lasts from June to October. Mean annual rainfall is 410 mm (1961–1990) but exhibits substantial inter-annual variability with a low of 373 mm in 1979 and a recently recorded high of 550 mm in 2019; recent monitoring records feature gaps. Mean daily temperatures range between 19 and 29 °C; potential evapotranspiration ranges from 1,800 to 2,100 mm/year. The Thiaroye aquifer comprises unconsolidated Quaternary sands with intercalations of sandy clay in places. Its thickness varies between 5 m (southeast) to 40 m (west) and 75 m (northwest). Hydraulic conductivity (K) of the unconfined aquifer ranges from 10−3 to 10−5 m/s (Cissé Faye et al. 2001) and specific yield is estimated to be ∼0.20 from pumping tests and laboratory column tests (Diédhiou et al. 2012).

Figure 1

Map of the Thiaroye and Infrabasaltic aquifers underlying Dakar on the Cap Vert peninsula showing areas of predominant sanitation facilities; inset maps provide the geographical context of Senegal and Cap Vert peninsula.

Figure 1

Map of the Thiaroye and Infrabasaltic aquifers underlying Dakar on the Cap Vert peninsula showing areas of predominant sanitation facilities; inset maps provide the geographical context of Senegal and Cap Vert peninsula.

Close modal

The study area, located within the departments of Guédiawaye, Pikine, and Rufisque as well as part of the Thiès region (Figure 1), is home to more than 1.6 million people, 11% of the national population and 52.5% of the population of Dakar (ANSD 2016). It is bounded to the west, north and south by the Atlantic Ocean and to the east by the cliff of Thiès. Population densities can reach up to 9,589 people per km2 with an average household size of 6 individuals. Sanitation provision in the study area derives from on-site systems that consist almost entirely of septic tanks; access to on-site sanitation is estimated to be ∼95% (ONAS 2010). Faecal loading from septic-tank effluent has progressively contaminated the Thiaroye aquifer (Diédhiou 2011) from which abstraction for public water supplies has declined by 84% from 3.7 × 106 m3/year in 1968 to 5.9 × 105 m3/year in 2009 (Diouf 2012). Groundwater still supplies nearly 50% of the water withdrawn in Dakar for domestic purposes but because of the high faecal contamination, this groundwater is now almost entirely imported from deep aquifers outside of Dakar. Small-scale abstractions from the Thiaroye aquifer still occur via some boreholes, dug-wells and hand-tubewells. Previous studies examining stable-isotope ratios (δ15NNO3, δ18ONO3) trace high nitrate concentrations to faecal sources (Diédhiou 2011).

Mapping of on-site sanitation facilities

Mapping of on-site sanitation facilities began with the imposition of a grid in QGIS (v. 2.18.4) on the area underlain by Quaternary sands in the Cap Vert Peninsula. An object-oriented classification (Hájek 2012) of high-resolution satellite images (Quickbird, 6 December 2016) was then performed in Envi (v. 5.1) that required a lengthy (nine-month), painstaking supervision process informed by visual photo-interpretations and field surveys (10–17 March 2018). As individual on-site sanitation facilities such as septic tanks could not be identified directly, we employed the assumption that each house or, more specifically roof of a house, possessed one septic tank or pit latrine. Auxiliary images [Geoeye (November 10, 2012), Orbview (November 20, 2009)] were used to assist the interpretation of optical imagery and to select training samples and validation points for classification (Table 1). Through this approach we estimated the number of on-site sanitation facilities within a hectare (100 × 100 m) grid across the unsaturated zone of the shallow aquifer over a total area of 520 km2 comprising 51,500 grids.

Table 1

Optical satellite images used in the analysis of on-site sanitation density in the Thiaroye aquifer of Dakar

Type of satellite image and useAcquisition date Resolution (m)Source
Classified and interpreted image (Quickbird) December 6, 2016 0.6 Digital Gobe 
Interpreted auxiliary image (Orbview) November 20, 2009 1.6 Orbview 
Interpreted auxiliary image (Geoeye)  November 10, 2012 0.6 Geoeye 
Type of satellite image and useAcquisition date Resolution (m)Source
Classified and interpreted image (Quickbird) December 6, 2016 0.6 Digital Gobe 
Interpreted auxiliary image (Orbview) November 20, 2009 1.6 Orbview 
Interpreted auxiliary image (Geoeye)  November 10, 2012 0.6 Geoeye 

Classification of the Quickbird satellite imagery required preliminary processing (i.e. calibration, radiometric enhancement and geometric correction) and an object-oriented classification with segmentation process. Radiometric calibration of satellite imagery makes it possible to convert the digital signal recorded by the satellite into a physical variable such as radiance in order to discern objects and select learning samples. Radiometric enhancement stretches the histogram of the satellite image (coded to 8 bits) so that it extends across the whole range of radiometric responses (i.e. 1–255 patterns). An accuracy assessment was then undertaken to assess classification errors. For each of the 10 classes, 100 test pixels were created at points visually identified as the referenced class in the imagery and then compared with the corresponding location in the classified image for accuracy. The overall performance of the classification gives very satisfactory results with an overall accuracy of 93% and a Kappa index of the order of 0.93 (Table 2).

Table 2

Confusion matrix and Kappa index derived from the object-oriented classification of satellite imagery

Class valueC0C1C2C3C4C5C6C7C8C9TotalU AccuracyKappa
C0 93 100 0.93 
C1 91 100 0.92 
C2 94 100 0.94 
C3 94 100 0.94 
C4 92 100 0.95 
C5 93 00 100 0.93 
C6 95 100 0.95 
C7 92 100 0.92 
C8 96 100 0.96 
C9 91 100 0.91 
Total 103 92 97 105 99 96 106 101 103 98 1000 
P Accuracy 0.90 0.96 0.90 0.95 0.96 0.89 0.91 0.93 0.92 0.93 
Kappa 0.93 
Class valueC0C1C2C3C4C5C6C7C8C9TotalU AccuracyKappa
C0 93 100 0.93 
C1 91 100 0.92 
C2 94 100 0.94 
C3 94 100 0.94 
C4 92 100 0.95 
C5 93 00 100 0.93 
C6 95 100 0.95 
C7 92 100 0.92 
C8 96 100 0.96 
C9 91 100 0.91 
Total 103 92 97 105 99 96 106 101 103 98 1000 
P Accuracy 0.90 0.96 0.90 0.95 0.96 0.89 0.91 0.93 0.92 0.93 
Kappa 0.93 

The object-oriented classification was preceded by segmentation which allowed us to refine the object-oriented classification by reducing as much as possible spectral confusions. This process made it possible to map surfaces occupied by houses based not only on their spectral values but also on their morphological characteristics. As a result, the analysis was able to discriminate as best as possible areas occupied by the houses from areas not occupied by the houses. Ground-truthing field surveys were facilitated by consulting cadastral maps of each district community to obtain an overview of the average size of houses, usually 15 × 10 m, but occasionally 7.5 × 10 m. Field surveys were conducted along 10 well-distributed, validation grid transects (200 × 300 m) with the aid of GPS-marked boundaries. During these, the location of encountered houses and type of on-site sanitation facilities (e.g. septic tanks, pit latrines) were recorded; 1,267 houses were visited to validate mapping of on-site sanitation facilities.

Sampling and analysis of indicators of faecal contamination (nitrate, E. coli)

Sampling of indictors of faecal contamination (nitrate, E. coli) in groundwater was carried out over a three-year period (2017–2019) using a network of 61 wells including dug-wells, piezometers, hand tubewells and boreholes; wells range in depth from 3 to 14.8 m and are distributed across the shallow aquifer. The network considered the operability of groundwater sources (still in use by users), their distribution in the area under the influence of faecal contamination, and their remoteness from agricultural activities. The number of sources sampled before and after the monsoon each year varied due to changes in site access and field logistics: 48 in 2017, 55 in 2018, 38 in 2019 (Tables S2 and S3). Groundwater samples were collected in 250 mL HDPE bottles after purging each groundwater source (unless in constant use) and stored in a cold box for transport to laboratories. Sample bottles for bacteriological analysis were collected in sterilized bottles and, after sampling, kept in ice at temperatures of ∼4 °C; all samples were transported to the laboratory within 1 hour of collection and analysed within 24 hours of collection. Analysis of nitrate and other major ions was conducted using a Dionex™ Aquion™ Ion Chromatography System (ThermoFisher Scientific, Waltham USA) following standard methods (Rice et al. 2017); E. coli counts were determined by fluorescence in situ hybridization using an ESCO 473 probe (Poppert et al. 2005) in which bacterial cells were fixed according to the method described by Wallner et al. (1996). For nitrate concentrations, only analyses with a charge-balance error (CBE) of less than 10% were correlated with on-site sanitation density; 98% of employed analyses had a CBE of <5%.

Analysis of the relationship between on-site sanitation density and groundwater quality

The relationship between the estimated density of on-site sanitation facilities and the quality of groundwater was assessed through correlations with both nitrate concentrations and E. coli counts observed in sampled groundwater sources. Correlation analyses were carried out on wells within the Thiaroye aquifer (520 km2) that were remote from agricultural activity. Nitrate concentrations recorded during pre- and post-monsoon sampling in 2017, 2018 and 2019 were averaged to a mean value for the period from 2017 to 2019. For E. coli, results from three sampling campaigns (post-monsoon and pre-monsoon 2017, post-monsoon 2018) were integrated into a median value and classified into World Health Organization (WHO 1997) drinking-water quality risk categories: Very Low (0 cfu), Low (1–9 cfu), Medium (10–99 cfu), High (100–999 cfu) and Very High (1,000 + cfu).

Linear regression was employed to test for possible association (dependency) between nitrate contamination (independent variable) and the density of on-site sanitation facilities (dependent variable). A coefficient of determination (r2) was used to indicate the strength of the linear regression. For E. coli counts, box plots showing the median, the interquartile range and the 5th and 95th percentile points were also used to assess its relationship to the estimated density of on-site sanitation facilities. Spatially, this comparison related the number of septic tanks and pit latrines in each 9 ha grid (i.e. 9 grids of 100 × 100 m) centered on the sampled waterpoint (i.e. shallow groundwater source).

Ethical considerations

Permission was sought and obtained from the Directorate of Water Resources Management and Planning (i.e. Direction de la Gestion et de la Planification des Ressources en Eau, Dakar) and the UCAD Research Ethics Committee before conducting the study; informed consent was also secured from owners and users of dug-wells and on-site sanitation facilities in advance of questions posed regarding the type of on-site sanitation employed, user-interface (e.g. squat versus sitting toilet) and frequency of emptying.

Mapping on-site sanitation facilities results

On-site sanitation mapping reveals the density of on-site sanitation facilities per hectare (Figure 2). In total, the analysis identified 253,014 septic tanks over an area of 520 km2. Densities of on-site sanitation vary between 1 and 70 septic tanks and pit latrines per hectare (100 × 100 m), with an average density of 20 per hectare. Cartographic results were validated from ground-truthing (Figure 3(a)) which consisted of a census of the number of houses located within the 10 validation grids distributed over the entire aquifer surface. Employed validation grid sizes have a rectangular shape of 300 m length and 200 m width (Figure 3(a)). The results show a strong correlation between the number of on-site sanitation facilities determined from optical imagery and ground-truthing surveys (Figure 3(b)). Analysis of the results reveals that the grids of density of 1 on-site sanitation facility per hectare represent 10% of the total number of grids. Grids of density ranging from 2 to 20 on-site sanitation facilities represent 42% of the total grid size, whereas grids of density ranging from 20 to 70 on-site sanitation facilities account for 47% of the total grid size (Figure S1). Validation results reveal that the types of on-site sanitation systems encountered are almost entirely (98%) septic tanks. Toilet-user interfaces are mostly squat toilets (72%). Toilets are frequently associated with a shower in the same room or next door and separated by a partition. Validation results by ground-truthing reveal also that residents need to empty their on-site sanitation facilities every three years on average (Table 3).

Table 3

Distribution and use of types of on-site sanitation facilities in the Thiaroye aquifer

Valida-tion gridX [Center of the grid]Y [Center of the grid]District communitySeptic tanks (%)Pit latrines (%)Mean number of usersMean frequency of emptying (years)Emptying by truck (%)Emptying manually (%)
Grid 1 238560 1632570 Golf Sud 100 10–20 84 16 
Grid 2 242530 1634140 Djida Thiaroye 100 10–20 92 
Grid 3 242790 1633795 Medina Gounass 97 10–20 70 30 
Grid 4 244890 1634001 Yeumbeul Sud 100 10–20 88 12 
Grid 5 244793 1631188 Thiaroye Sur Mer 94 10–20 54 48 
Grid 6 248000 1633700 Keur Massar 100 10–20 93 
Grid 7 242790 1633795 Keur Massar 100 10–20 74 26 
Grid 8 257326 1632464 Snngalkam 87 13 10–20 52 48 
Grid 9 257203 1638573 Snngalkam 100 05–10 53 47 
Grid 10 2571792 1650341 Kayar 97 20–30 52 48 
Average    98 10–20 71 29 
Valida-tion gridX [Center of the grid]Y [Center of the grid]District communitySeptic tanks (%)Pit latrines (%)Mean number of usersMean frequency of emptying (years)Emptying by truck (%)Emptying manually (%)
Grid 1 238560 1632570 Golf Sud 100 10–20 84 16 
Grid 2 242530 1634140 Djida Thiaroye 100 10–20 92 
Grid 3 242790 1633795 Medina Gounass 97 10–20 70 30 
Grid 4 244890 1634001 Yeumbeul Sud 100 10–20 88 12 
Grid 5 244793 1631188 Thiaroye Sur Mer 94 10–20 54 48 
Grid 6 248000 1633700 Keur Massar 100 10–20 93 
Grid 7 242790 1633795 Keur Massar 100 10–20 74 26 
Grid 8 257326 1632464 Snngalkam 87 13 10–20 52 48 
Grid 9 257203 1638573 Snngalkam 100 05–10 53 47 
Grid 10 2571792 1650341 Kayar 97 20–30 52 48 
Average    98 10–20 71 29 
Figure 2

Mapped density of on-site sanitation facilities (septic tanks, pit latrines) in the Thiaroye shallow aquifer estimated from Quickbird satellite image (acquired on December 6, 2016) and field surveys (10–17 March 2018); inset map shows the broader geographical context from Figure 1.

Figure 2

Mapped density of on-site sanitation facilities (septic tanks, pit latrines) in the Thiaroye shallow aquifer estimated from Quickbird satellite image (acquired on December 6, 2016) and field surveys (10–17 March 2018); inset map shows the broader geographical context from Figure 1.

Close modal
Figure 3

(a) Map of validation grids for the estimation of on-site sanitation density from optical satellite imagery; (b) cross-plot of on-site sanitation facilities estimated from remote sensing and observed during ground-truthing surveys (10–18 March 2018) on 200 × 300 m grid.

Figure 3

(a) Map of validation grids for the estimation of on-site sanitation density from optical satellite imagery; (b) cross-plot of on-site sanitation facilities estimated from remote sensing and observed during ground-truthing surveys (10–18 March 2018) on 200 × 300 m grid.

Close modal

Groundwater quality

Mean nitrate concentrations recorded in 2017, 2018, and 2019 vary considerably in space across the Thiaroye aquifer with values ranging from 3 mg/L to in excess of 500 mg/L (Figure 4(a)–4(c)). Higher nitrate concentrations are generally observed in the more densely populated areas on the western side of the Cap Vert peninsula underlain by the Thiaroye aquifer. In 32 of the 39 (82%) groundwater sources for which nitrate data are available, nitrate concentrations exceed the World Health Organization's guideline value of 50 mg/L for drinking water (Table S2). Curiously, high temporal variability in mean nitrate concentrations is also observed with a median coefficient of variation of 50%. Median E. coli counts in 61 groundwater sources from 2017 and 2018 for which data are available (Figure 4(d)) also exhibit high spatial variability with values ranging from 0 and 1,270 E. coli per 100 mL; 50% of sampled sources showed E. coli counts exceeding the WHO guide value of 0 (Table S3).

Figure 4

Distribution of the mean nitrate concentrations (a – in 2019, b – in 2018, c – in 2017) and median E. coli counts (d – from 2017 to 2018) measured in the Thiaroye shallow aquifer of Dakar.

Figure 4

Distribution of the mean nitrate concentrations (a – in 2019, b – in 2018, c – in 2017) and median E. coli counts (d – from 2017 to 2018) measured in the Thiaroye shallow aquifer of Dakar.

Close modal

Relationship between on-site sanitation density and shallow groundwater faecal contamination

Groundwater sources with very high nitrate concentrations and E. coli counts generally but not exclusively correspond to areas with very high on-site sanitation densities. In areas where the density of on-site sanitation is lower, there is an associated decrease in nitrate concentrations in sampled groundwater (Figure 5(a)) but no consistent trend in E. coli (Figure 5(c)). A statistically significant relationship (p « 0.01) exists between mean (20172019) nitrate concentrations in shallow groundwater sources and on-site sanitation density in which 56% of the variation in nitrate is explained by the fitted regression with on-site sanitation density (r2 = 0.55, Figure 5(b)). In contrast, no statistically significant relationship (p = 0.42) exists between median E. coli counts and on-site sanitation density (r2 = 0.01, Figure 5(c)). Further, grouping values of E. coli counts into WHO (1997) risk categories (Figure 5(d)) does not identify a general relationship between faecal bacteriological contamination and on-site sanitation density.

Figure 5

Observed mean nitrate concentrations (a – from 2017 to 2019) and median E. coli counts according to WHO categories (c – from 2017 to 2018) in groundwater sources overlain on estimated density of on-site sanitation facilities; (b) linear correlations between these parameters; (d) Boxplots of E. coli count according to WHO (1997) drinking-water quality risk categories and density of on-site sanitation facilities. Box boundaries illustrate the 25th and 75th percentiles, the line within the box is the median, and the whiskers are the 10th and 90th percentiles.

Figure 5

Observed mean nitrate concentrations (a – from 2017 to 2019) and median E. coli counts according to WHO categories (c – from 2017 to 2018) in groundwater sources overlain on estimated density of on-site sanitation facilities; (b) linear correlations between these parameters; (d) Boxplots of E. coli count according to WHO (1997) drinking-water quality risk categories and density of on-site sanitation facilities. Box boundaries illustrate the 25th and 75th percentiles, the line within the box is the median, and the whiskers are the 10th and 90th percentiles.

Close modal

Previous studies mapping the density of on-site sanitation facilities in urban areas of sub-Saharan Africa have relied upon ground-based surveys over small areas of ≤7 km2 (Wright et al. 2012; Nkhuwa et al. 2015). Here, we employ an assumption, validated from ground-truthing surveys in Dakar, that each house or dwelling identified from high-resolution optical imagery (100 × 100 m grid) possesses an on-site sanitation facility where sewerage does not exist. Object-oriented classification of optical satellite imagery then enabled 253,014 on-site sanitation facilities comprising primarily septic tanks to be mapped over an area of 520 km2. This process required a lengthy, painstaking supervision process based on visual photo-interpretations of classified and auxiliary images in which individual grids were checked for the validity of their identification/characterization of the number of dwellings (houses). This study represents one of the first large-scale assessments of the density of on-site sanitation facilities in an African city.

Shallow groundwater across the Thiaroye aquifer of Dakar shows high levels of faecal contamination consistent with previous studies (e.g. Tandia et al. 1999; Diédhiou et al. 2012; Cissé Faye et al. 2019; Sorensen et al. 2020). Despite high levels of contamination, the aquifer remains an important source of water for self-supply due to limited access to piped water. Inter-annual variability in recorded nitrate concentrations in shallow groundwater (Figure 4(a)–4(c), Table S2) is substantial as indicated by a median co-efficient of variation in mean nitrate concentrations (2017–2019) of 50%. As systematic analytical errors are not expected (all but one analysis of solute concentrations has a CBE of <5%), other factors may explain this variability in nitrate including water-table depth and the risk of episodic flooding of septic tanks; median depth to the water table at sampling locations is 3.3 m despite guidelines specifying a minimum vertical distance of 3 m (Gabert et al. 2012). E. coli counts (Table S3) and associated drinking-water quality risk categories vary substantially in space and inconsistently with nitrate concentrations. Effluent pathways are expected to differ as faecal bacteria are particles, not true solutes, and often sample different pathways in the subsurface from their source to a receptor such as a pumping well (Taylor et al. 2004b). The observed correlation association between nitrate concentrations in shallow groundwater and the density of on-site sanitation facilities is statistically significant but moderate, explaining 55% of the observed variation in nitrate. Other factors that may contribute to observed nitrate concentrations include the lithology of the unsaturated zone, septic-tank functionality, household size, and grey-water discharges.

The statistically significant association between faecal effluent loading from on-site sanitation and nitrate concentrations suggests that shallow groundwater retains the ‘signature’ of constant faecal loading from overlying on-site sanitation facilities comprising primarily septic tanks. In Thiaroye area of Dakar, local hydrogeological conditions have, in part, facilitated this. The intergranular nature of the Quaternary sand aquifer including its high effective porosity (∼0.30; Diedhiou 2011), have promoted accumulation of pollutants over time. This process has been aided by relatively low hydraulic gradients (0.001–0.003; Cissé Faye et al. 2019), driving groundwater flow, that are associated with the cessation of intensive groundwater abstraction from the Thiaroye aquifer due to the excessive faecal contamination. This termination of pumping has reduced sub-horizontal hydraulic gradients in the shallow aquifer, which combined with local boundary conditions for drainage controlled by sea-level, restricts groundwater flow. In addition to seasonal diffuse recharge from rainfall (Cissé Faye et al. 2019); the widely distributed and constant nature of faecal effluent loading from the vast network of unimproved on-site sanitation facilities comprises an additional diffuse ‘recharge’ flux.

The moderate, statistically significant correlation between nitrate concentrations in groundwater sources and on-site sanitation density (Figure 5(b)) provides a rough, empirically derived estimate of the capacity of the Quaternary sand aquifer to attenuate faecal loading. Switching the dependent and independent variables (i.e. Y = on-site sanitation density; X = groundwater nitrate concentration), the regression model (Figure 5(b)) becomes Y = 0.66X + 1.75. Applying the WHO drinking-water guideline value of 50 mg/L and accounting for the fact that the regression model is for on-site sanitation densities per 9 ha, the linear relationship suggests (with large error) that this threshold nitrate concentration is exceeded where the number of septic tanks (or pit latrines) exceeds 4 (±4) per hectare. Notwithstanding the uncertainty in this estimate, the result suggests that for many areas of the Thiaroye aquifer, particularly to the west in Guédiawaye and Pikine (Figure 1) with the highest density of on-site sanitation facilities, the ability of the Thiaroye aquifer attenuate faecal loading from on-site sanitation has long been exceeded with high nitrate concentrations first detected in the early 1980s. This finding is consistent with the subsequent shift around the year 2000 in the withdrawal of groundwater locally from the Thiaroye aquifer to the importation of groundwater from beyond the Cap Vert peninsula for the water supply of Dakar (Cissé Faye et al. 2019).

Additional work is required to replicate and extend these analyses in other aquifer environments, urban settings, and types of on-site sanitation facilities. As the proportion of dwellers reliant upon on-site sources has risen considerably over the last few decades (Healy et al. 2018), our results provide a tentative marker of a threshold density of on-site sanitation facilities for urban planning and water safety plans with a similar hydrogeological context in low-income urban and peri-urban areas as well as refugee and IDP (internally displaced peoples) camps dominated by use of on-site water and sanitation facilities. As the finite capacity of the subsurface to conjunctively attenuate faecal effluent and provide safe water has been exceeded in many areas of the Thiaroye aquifer, sanitation options that will reduce faecal loading to underlying groundwater are restricted to sewerage or on-site dry (no-flush) toilet systems (e.g. earth auger toilet). Recent research in the Thiaroye area (Eggleton 2018) indicates that implementation of new technological solutions such as dry toilets needs to consider cost, cultural attitudes, and the viability of supply chains to promote uptake by user communities.

On-site sanitation facilities have been mapped over an area of 520 km2 in densely populated, low-income areas of Dakar (Senegal) using an intensely supervised, object-oriented classification of optical satellite imagery (QuickBird). Employing the assumption, supported by ground-truthing surveys, that each identified dwelling possesses one on-site sanitation facility, >253,000 on-site sanitation facilities were mapped with densities ranging from 1 to 70 septic tanks or pit latrines per hectare. The density of on-site sanitation facilities comprising primarily septic tanks (∼98%) is correlated with the magnitude of faecal contamination (nitrate) observed in shallow groundwater within unconsolidated Quaternary sands.

The analysis highlights the risk posed by dense networks of on-site sanitation facilities to shallow groundwater quality. Urban areas with high densities of on-site sanitation facilities and associated loading of faecal effluent to the subsurface, exhibit greater faecal pollution from solutes (nitrate). The moderate, statistically significant association between faecal nitrate and the density of on-site sanitation facilities suggests that densities exceeding 4 (±4) septic tanks per hectare in the Thiaroye shallow aquifer pose a risk to human health. As many areas underlain by the Thiaroye aquifer of Dakar have on-site sanitation densities that exceed the threshold, our results highlight the health risk posed by self-supply options employing shallow wells. Replication of the analytical approach employed here to other conurbations in sub-Saharan Africa is recommended to better understand the attenuation capacity of urban aquifer systems in different contexts and to inform use of low-cost sanitation systems restricting faecal effluent.

The authors gratefully acknowledge support under the AfriWatSan project funded by The Royal Society (UK) and the UK Department for International Development under the Africa Capacity Building Initiative (ACBI) programme (Ref. AQ140023). Furthermore, the authors gratefully acknowledge the assistance provided by colleagues of the Department of Geology and other members of the project (Pr. Serigne Faye, Mathis Diedhou, Ousmane Coly Diouf, Djim Diongue, Habsatou Tall, Moussa Sow, Alpha Diao and Aissatou Tounkara) during the field investigations and sampling campaigns from 2017 to 2019. The views expressed are not necessarily endorsed by the Royal Society or DFID, which accept no responsibility for such views or information or for any reliance placed on them.

All relevant data are included in the paper or its Supplementary Information.

Adelana
S.
MacDonald
A. M.
2008
Applied Groundwater Studies in Africa
.
CRC Press
,
Leiden
,
Netherlands
, pp.
127
148
.
(IAH selected papers on hydrogeology, 13)
.
ANSD
2016
National Census of the Population of Senegal in 2016
.
Excel sheet 843 rows and 25 columns. National Agency for Statistics and Demography, Dakar, Senegal
.
ARGOSS
2001
Guidelines for Assessing Risk to Groundwater From On-Site Sanitation
.
British Geological Survey Commissioned Report CR/01/142, p. 97
.
Buss
S. R.
Rivett
M. O.
Bemment
C. D.
2005
Attenuation of Nitrate in the Subsurface Environment
.
Technical Report, 99 pages. Environment Agency Rio House Waterside Drive, Aztec West Almondsbury, Bristol, BS32 4UD
.
Cissé Faye
S.
Faye
S.
Gaye
C. B.
Faye
A.
Wohnlich
S.
2001
Risk assessment of rising groundwater level in the Thiaroye suburb zone (Dakar, Senegal)
. In
Proc.of the XXXI IAH Congress on New Approach Characterizing Groundwater Flow
,
September 2001
,
Munich
.
Balkema, Dordrecht
,
The Netherlands
, Vol
2
. pp.
1149
1153
.
Cissé Faye
S.
Diongue
M. L.
Pouye
A.
Gaye
C. B.
Travi
Y.
Wohnlich
S.
Taylor
R. G.
2019
Tracing natural groundwater recharge to the Thiaroye aquifer of Dakar, Senegal
.
Hydrogeology Journal
27
(
3
),
1067
1080
.
Comte
J. C.
Cassidy
R.
Obando
J.
Robins
N.
Ibrahim
K.
Melchioly
S.
Davies
J.
2016
Challenges in groundwater resource management in coastal aquifers of East Africa: investigations and lessons learnt in the Comoros Islands, Kenya and Tanzania
.
Journal of Hydrology: Regional Studies
5
,
179
199
.
Cuthbert
M. O.
Taylor
R. G.
Favreau
G.
Todd
M. C.
Shamsudduha
M.
Villholth
K. G.
MacDonald
A. M.
Scanlon
B. R.
Kotchoni
D. O. V.
Vouillamoz
J.-M.
Lawson
F. M. A.
Adjomayi
P. A.
Kashaigili
J.
Seddon
D.
Sorensen
J. P. R.
Ebrahim
G. Y.
Owor
M.
Nyenje
P. M.
Nazoumou
Y.
Goni
I.
Ousmane
B. I.
Sibanda
T.
Ascott
M. J.
Macdonald
D. M. J.
Agyekum
W.
Koussoubé
Y.
Wanke
H.
Kim
H.
Wada
Y.
Lo
M.-H.
Oki
T.
Kukuric
N.
2019
Observed controls on resilience of groundwater to climate variability in sub-Saharan Africa
.
Nature
572
(
7768
),
230
234
.
DEW Point and DFID
2009
National Regulations on the Safe Distance Between Latrines and Waterpoints, Final Report
. p.
6
.
DEW Point Enquiry No. A0304
.
Diedhiou
M.
2011
Approche multitraceur géochimique et isotopique à l'identification des sources de la pollution nitratée et des processus de nitrification et dénitrification dans la nappe de Thiaroye
.
Univ. Cheikh Anta Diop de Dakar
, p.
210
.
Diédhiou
M.
Cissé Faye
S.
Diouf
O. C.
Faye
S.
Faye
A.
Re
V.
Wohnlich
S.
Wisotzky
F.
Schulte
U.
Maloszewski
P.
2012
Tracing groundwater nitrate sources in the Dakar suburban area: an isotopic multi-tracer approach
.
Hydrological Processes
26
(
5
),
760
770
.
Eggleton
F.
2018
Factors of Demand and Supply Influencing the Uptake of Toilets That Reduce Groundwater Contamination in Peri-Urban Dakar, Senegal
.
Unpublished MSc Thesis
,
University College London
,
UK
, p.
96
Foster
S.
Chilton
J.
2017
Groundwater management: policy principles & planning practices. In:
Advances in Groundwater Governance
(K. Villholth, E. Lopez-Gunn, K. Conti, A. Garrido & J. van der Gun, eds
).
CRC Press
,
Boca Raton, FL
, pp.
73
95
.
Gabert
J.
Désille
D.
Le Jallé
C.
Monvois
J.
Frenoux
C.
Guillaume
M.
2012
Choisir des solutions techniques adaptées pour l'assainissement liquide
.
Eau et Assainissement pour tous. Guides méthodologiques N°4. pS-Eau/PDM/, p. 135
.
Gaye
C. B.
Tindimugaya
C.
2019
Challenges and opportunities for sustainable groundwater management in Africa
.
Hydrogeology Journal
27
(
3
),
1099
1110
.
Harman
J.
Robertson
W. D.
Cherry
J. A.
Zanini
L.
1996
Impacts on a sand aquifer from an old septic system: nitrate and phosphate
.
Ground Water
34
,
1105
1114
.
Healy
A.
Upton
K.
Bristow
G.
Allan
S.
Bukar
Y.
Capstick
S.
Danert
K.
Furey
S.
Goni
I.
MacDonald
A.
Theis
S.
Tijani
M. N.
Whitmarsh
L.
2018
Resilience in Groundwater Supply Systems: Integrating Resource Based Approaches with Agency, Behaviour and Choice
.
Technical report
,
Cardiff University
,
UK
, p.
51
.
Howard
G.
Pedley
S.
Barrett
M.
Nalubega
M.
Johal
K.
2003
Risk factors contributing to microbiological contamination of shallow groundwater in Kampala, Uganda
.
Water Research
37
(
14
),
3421
3429
.
Kiptum
C. K.
Ndambuki
J. M.
2012
Well water contamination by pit latrines: a case study of Langas
.
International Journal of Water Resources and Environmental Engineering
4
,
35
43
.
Lapworth
D. J.
Nkhuwa
D. C. W.
Okotto-Okotto
J.
Pedley
S.
Stuart
M. E.
Tijani
M. N.
Wright
J.
2017
Urban groundwater quality in sub-Saharan Africa: current status and implications for water security and public health
.
Hydrogeology Journal
25
(
4
),
1093
1116
.
Mbaka
P. K.
Mwangi
J. K.
Kiptum
C. K.
2017
Assessment of water quality in selected shallow wells of Keiyo Highlands, Kenya
.
African Journal of Science, Technology, Innovation and Development
9
(
3
),
329
338
.
Morella
E.
Foster
V.
Banerjee
S. G.
2008
Climbing the Ladder: The State of Sanitation in Sub-Saharan Africa
.
Technical report
.
Africa Infrastructure Country Diagnostic (AICD), World Bank
, p.
62
.
Nayebare
J. G.
Kulabako
R.
Owor
M.
Campos
L. C.
Fottrell
E.
Taylor
R. G.
2020
WASH conditions in a small town in Uganda: how safe are on-site facilities?
Journal of Water, Sanitation and Hygiene for Development
10
,
96
110
.
Nkhuwa
D. C. W.
Namafe
C. M.
Chabwela
H.
Phiri
L.
Chompolola
A.
Mweemba
C. E.
Kabika
J.
2015
Groundwater Resource Management in the St
.
IGRAC
,
Bonaventure Township, Lusaka, Delft
.
Okotto
L.
Okotto-Okotto
J.
Price
H.
Pedley
S.
Wright
J.
2015
Socio-economic aspects of domestic groundwater consumption, vending and use in Kisumu, Kenya
.
Applied Geography
58
,
189
197
.
ONAS (Office National de l'Assainissement du Sénégal)
2010
Etude d'Actualisation du Plan Directeur d'Assainissement Liquide de Dakar 2025 - les Annexes du Rapport de Mission A
.
Poppert
S.
Essig
A.
Stoehr
B.
Steingruber
A.
Wirths
B.
Juretschko
S.
Reischl
U.
Wellinghausen
N.
2005
Rapid diagnosis of bacterial meningitis by real-time PCR and fluorescence in situ hybridization
.
Journal of Clinical Microbiology
43
(
7
),
3390
3397
.
Rice
E. W.
Baird
R. B.
Eaton
A. D.
(eds.).
2017
Standard Methods for the Examination of Water and Wastewater
, 23rd edn.
American Water Works Association
,
Denver
,
USA
.
Sorensen
J. P. R.
Diaw
M. T.
Pouye
A.
Roffo
R.
Diongue
D. M. L.
Cissé Faye
S.
Gaye
C. B.
Fox
B. G.
Goodall
T.
Lapworth
D. J.
MacDonald
A. M.
Reade
D. S.
Ciric
L.
Taylor
R. G.
2020
In-situ fluorescence spectroscopy indicates total bacterial abundance and dissolved organic carbon
.
Science of the Total Environment
doi:10.1016/j.scitotenv.2020.139419
.
Taylor
R. G.
Barrett
M. H.
Tindimugaya
C.
2004a
Urban areas of sub-Saharan Africa; weathered crystalline aquifer systems
. In:
Urban Groundwater Pollution
, Vol.
24
, (
Lerner
D.
, ed.).
International Contributions to Hydrogeology
,
CRC Press
,
Boca Raton
, pp.
155
179
.
Taylor
R. G.
Cronin
A. A.
Pedley
S.
Atkinson
T. C.
Barker
J. A.
2004b
The implications of groundwater velocity variations on microbial transport and wellhead protection: review of field evidence
.
FEMS Microbiology Ecology
49
,
17
26
.
Taylor
R. G.
Miret-Gaspa
J.
Tumwine
L.
Mileham
R.
Howard
G.
Kulabako
R.
2009
Increased risk of diarrhoeal diseases from climate change: evidence from communities supplied by groundwater in Uganda
. In:
Groundwater and Climate in Africa
, Vol.
334
(
Taylor
R. G.
Tindimugaya
C.
Owor
M.
Shamsudduha
M.
, eds).
IAHS Publication
,
Wallingford
,
UK
, pp.
15
19
.
Templeton
M. R.
Hammoud
A. S.
Butler
A. P.
Braun
L.
Foucher
J. A.
Grossmann
J.
Boukari
M.
Faye
S.
Jourda
J. P.
2015
Nitrate pollution of groundwater by pit latrines in developing countries
.
AIMS Environmental Science
2
(
2
),
302
331
.
Tucker
J.
MacDonald
A. M.
Coulter
L.
Calow
R. C.
2014
Household water use, poverty and seasonality: wealth effects, labour constraints, and minimal consumption in Ethiopia
.
Water Resources and Rural Development
3
,
27
47
.
UNICEF and WHO
2015
Progress on Sanitation and Drinking Water: Update and MDG Assessment
.
WHO Library Cataloguing-in-Publication Data. Technical report
.
WHO-UNICEF
,
Geneva
,
Switzerland
, p.
82
.
Wallner
G.
Steinmetz
I.
Bitter-Suermann
D.
Amann
R.
1996
Combination of rRNA-targeted hybridization probes and immuno-probes for the identification of bacteria by flow cytometry
.
Systematic and Applied Microbiology
19
(
4
),
569
576
.
WHO
1997
Guidelines for Drinking-Water Quality
, 2nd edn.
WHO Press
,
Geneva
,
Switzerland
.
Wright
J. A.
Cronin
A.
Okotto-Okotto
J.
Yang
H.
Pedley
S.
Gundry
S. W.
2012
A spatial analysis of pit latrine density and groundwater source contamination
.
Environmental Monitoring and Assessment
185
(
5
),
426
4272
.
This is an Open Access article distributed under the terms of the Creative Commons Attribution Licence (CC BY 4.0), which permits copying, adaptation and redistribution, provided the original work is properly cited (http://creativecommons.org/licenses/by/4.0/).

Supplementary data