In 2010, the Mannheim wastewater treatment plant was expanded with an adsorptive treatment stage to remove organic micropollutants (OMPs). Differences in the removal efficiencies of the OMPs investigated were determined over four years of operation by applying different powdered activated carbon (PAC) products and a constant volume-proportional dosing of 10 mg PAC/L. Possible influences on the removal efficiency are discussed here on the basis of the data obtained, exemplified for the analgesic diclofenac. The analyses show that the removal efficiency is influenced significantly by the spectral absorption coefficient (SAC) of the biologically treated wastewater at a wavelength of 254 nm (SAC254). Therefore, in order to ensure the constant treatment performance desired, the dosage of PAC should be adjusted to the measured SAC254 values. Moreover, as the SAC254 reduction correlates with the removal efficiency of OMPs, the additional determination of its reduction allows indirect control of the actual removal performance achieved. The SAC254 reduction can also be used for targeted control of the PAC dosage.
INTRODUCTION
Municipal wastewater treatment plants (WWTPs) are considered major input paths for organic micropollutants (OMPs) to water bodies, as, in the majority of the cases, they are not designed to remove them (Ternes 2001; Reemtsma et al. 2006; Kasprzyk-Hordern et al. 2009). Since about 2005, numerous investigations have been carried out, in Germany and Switzerland, to develop suitable process techniques for the targeted removal of OMPs. Based on current knowledge and experience, the application of both adsorptive processes with activated carbon and oxidative processes with ozone are considered the most viable techniques for the effective removal of a large number of OMPs from municipal wastewater (Abegglen & Siegrist 2012; DWA 2015).
The introduction of measures for OMP removal in WWTPs became a legal requirement in Switzerland in 2016 (WPA 2016), whereas in Baden-Württemberg, a federal state in Germany, it was done either voluntarily or under an agreement between the operator and the regulator. Since 2010, eight WWTPs in Baden-Württemberg have been expanded with an advanced treatment stage targeted on OMPs. In all cases the method used was treatment with powdered activated carbon (PAC) which had proved to be the most efficient in long-term pilot-scale investigations at Biberach University of Applied Sciences (Metzger 2010). In this method, the PAC is first added to a separate adsorption stage downstream of the biological treatment and subsequently recirculated back into the biological stage for further use in a counter-flow principle. Studies have shown that OMPs are removed to a large extent from the wastewater with as little as 10 mg PAC/L (Rößler & Metzger 2014). Despite using the same PAC product and constant volume-proportional dosage of 10 mg PAC/L, some significant fluctuations occurred in the removal efficiencies of the OMPs investigated at every WWTP studied. It is therefore necessary to learn more about PAC dosage, in order to be able to meet possible future OMP removal requirements. An additional difficulty in operational monitoring of the adsorption stage for the targeted removal of OMPs is that these substances cannot readily be analyzed in situ directly in the facility's own laboratory. Thus, real time control of the OMP removal performance can only be achieved by measurement of a surrogate parameter. A comparatively simple, robust and inexpensive measurement is needed, if it is to be practical in use in both small and large WWTPs. Altmann et al. (2014) and Zietzschmann et al. (2014) have obtained good correlation, in laboratory experiments, between OMP removal performance and reduction of the spectral absorption coefficient (SAC) at 254 nm wavelength (SAC254). As far as is known, there are no reports to date of experience applying this surrogate parameter on an industrial scale.
The objective of this study, based on long-term operating data, is to indicate possible influences on the OMP removal performance in an adsorption stage, and, based on these findings, to derive a possible strategy for the monitoring and control of PAC dosage.
METHODS
Implementation of the adsorption stage with PAC at the Mannheim WWTP
The first full-scale implementation of an adsorption stage for OMPs occurred in summer 2010 at the Mannheim WWTP (capacity 725,000 PE), Baden-Württemberg. In order to obtain initial operating experience with the new technology, it was first implemented for a partial stream with a maximum flow of 300 L/s (Alt & Mauritz 2010). It was operated like that until the beginning of 2015. Subsequently the adsorption stage was extended so that a flow of 1,500 L/s, representing approximately 90% of the annual average wastewater flow, could be treated with PAC from summer 2016 (Kapp 2012).
Until the end of October 2012 the adsorption stage feed was quantity-based for the maximum flow of 300 L/s. During this time the average inflow was 160 L/s on days with dry weather conditions, while the retention time in the contact reactor was 75 minutes. From November 2012 until the beginning of 2015 a constant flow rate of 200 L/s was treated adsorptively. The retention time in this case was 60 minutes. However, the different retention times have no effect on OMP removal efficiency according to the results of own investigations (Metzger 2010).
Operation of the adsorption stage was under the scientific supervision of the Biberach University of Applied Sciences from 2010 to 2012, during which time detailed research was performed to investigate OMP removal by PAC (Metzger et al. 2012). In addition, the reduction in the estrogen effect of the wastewater was verified using active fish monitoring with male rainbow trout (Rößler & Kapp 2012). Afterwards the operation was continued without scientific supervision. Later, in 2014, further extensive measurements were done within a new investigation campaign by KomS.
Chemical dosing
Four different PAC products were tested during the approximately four-year period of operation. They were – ‘Norit SAE Super’ from Cabot, ‘AquaSorb 5000P’ from Jacobi, ‘Carbopal AP’ from Donau Carbon and ‘PAK C 880 SR’ from CarboTech.
The suitability of ‘Norit SAE Super’ for OMP removal had already been verified in several studies (Metzger 2010; Boehler et al. 2012; Kovalova et al. 2013; Margot et al. 2013). The other three PACs have been shown in investigations carried out by KomS as well as in other published studies removal performances comparable to ‘Norit SAE Super’ (Zietzschmann et al. 2014). In this paper the products are mentioned anonymously (PACs A-D). The treatment efficiencies presented were achieved with a dosage of 10 mg PAC/L in all cases.
Throughout the operating period, polyaluminium chloride was used as a flocculating agent both in the adsorption stage and upstream of the flocculant filter. In the period 2011/12, total flocculant dosing varied between 1.9 and 2.3 mg Al/L, while in 2014 dosing was at 1.2 mg Al/L. Both anionic and cationic polymers were used as flocculation aids.
Evaluation of the treatment performance
Treatment efficiency was evaluated by collecting 24-hour composite samples, taken in a flow-proportional manner from the adsorption stage influent and the flocculant filter effluent. The performance of the adsorption stage was not considered on its own due to the necessity for a downstream filter unit. The improvement in wastewater quality was rather evaluated through the selection of the two sampling points, indicating the overall performance of the ‘adsorptive system’ (=adsorption stage + filter). Before analysis, all samples were filtered using membranes (cellulose nitrate, pore size 0.45 μm, Sartorius, Germany).
The SAC254 was measured using a UV-VIS spectral photometer DR 5000 (Hach-Lange, Germany) and determination normally took place on working days.
In order to evaluate OMP removal performance in the adsorptive stage, it is sufficient to analyze only a few individual substances (Jekel & Dott 2013). The choice, however, should take into account substances that are permanently present in the secondary settling stage effluent and can also be removed to varying degrees by adsorption. For this purpose, the concentrations of the pharmaceuticals metoprolol, carbamazepine and diclofenac, the industrial chemical benzotriazole and the radio opaque substance iopamidol in the wastewater samples were determined at regular intervals. Metoprolol and carbamazepine are both very easily, benzotriazole is readily and iopamidol moderately adsorbed on PAC (Metzger et al. 2012). Samples for the determination of OMPs were taken only under dry weather conditions.
The analyses were performed with HPLC-MS by the DVGW (German Technical and Scientific Association for Gas and Water) Technology Centre for Water in Karlsruhe. The limit of determination was 50 ng/L in all cases.
RESULTS AND DISCUSSION
Operating results
Although the SAC254 reductions corresponding to influent wastewaters with the same SAC254 value fluctuate in a broad range, there is a general trend that with increasing SAC254 influent value, the percentage SAC254 reduction decreases when applying 10 mg PAC/L. Thus, if an SAC254 value of 15 m−1 is measured after biological treatment, then, on average, a reduction of 50% is observed, whereas at an SAC254 input value of 25 m−1, a reduction of only about 30% is detected.
Effects on OMP removal
Figure 4(a) indicates that higher input concentrations of diclofenac tend to result in lower percentage removal, regardless of the type of PAC used. With an input concentration of about 1.5 μg/L, the removal rate is between 80 and 90%, but it is 10 percentage points less with an adsorption stage influent concentration of 3.5 μg/L. However, if the results in Figure 4(a) are considered in terms of the different PAC products, it appears that PAC C has a slightly poorer removal performance than PACs A and B, as implied in Figure 2.
If, however, the influence of the dissolved residual organic matter on diclofenac removal, expressed by the SAC254, is also taken into account (Figure 4(b)), no differences can be identified between the removal performances of the four PACs. The lower diclofenac removal rates, between 70 and 80% with PAC C, are thought to arise from the fact that, on the corresponding days, a comparatively high SAC254 of more than 20 m−1 was measured in the adsorption stage influent.
Accordingly, the percentage removal of diclofenac appears to be influenced significantly by the SAC254 of the biologically treated wastewater, and rather less by the input concentration of diclofenac or the supposedly different removal performances of the four PAC products or delivered loads. It is concluded that, to achieve a specific treatment target, PAC dosage must be adjusted to the SAC254 of the adsorption stage influent.
Control and regulation of the PAC dosage
An additional measurement of the SAC254 in the effluent of the filter would also enable determination of the SAC254 reduction and thus, as Figure 5(b) shows, the indirect control of the scope of diclofenac removal. The SAC254 reduction can also be drawn on for the deliberate regulation of PAC dosage. Thus, for Mannheim WWTP, an SAC254 reduction of 40% is required to achieve a diclofenac removal of 80% in the adsorption stage, independent of the SAC254 in the adsorption stage influent. For other OMPs, corresponding correlations between percentage removal and the SAC254-specific PAC dosage, respectively the SAC254 reduction, are presented in the Supplementary Information in Figures S3 and S4.
CONCLUSIONS
In this study, based on long-term operating data from a WWTP, it is shown that steady removal of OMPs can be achieved by using 10 mg PAC/L in an adsorption stage. Despite the constant volume-proportional PAC input, differences were observed in OMP removal efficiency for the substances investigated. These are conditioned significantly by the SAC254 of the biologically treated wastewater, e.g., for the analgesic diclofenac. In order to comply with possible future requirements regarding the removal efficiencies for individual substances, it will thus not be sufficient to dose the PAC proportionally to the wastewater flow. It would be better to use an SAC254-specific PAC dosage rate, to achieve the constant level of treatment desired. The actual removal performance achieved can be controlled indirectly by the additional determination of the SAC254 reduction, which would enable a regulated PAC dosage, corresponding to the particular demand.
The analyses shown in this study are based on SAC254 values of membrane-filtered, 24-hour composite samples. If future regulations require that the PAC dosage has to be defined in relation to continuous determination of the SAC254 reduction, further research will be needed to investigate the suitability of SAC sensors for the application. In particular, it will be necessary to examine how well the influence of particles can be compensated for and whether any additional sample preparation is required in order to determine the SAC254 sufficiently accurately. If the findings of this study are to be generalized, it will be important to clarify whether the characteristic values determined for the Mannheim WWTP can be transferred to others using the same adsorptive process technology.
ACKNOWLEDEGEMENTS
This study was supported financially by the Regierungspräsidium Karlsruhe (regional board), the Ministry for the Environment, Climate and Energy Management in Baden-Württemberg and the Eigenbetrieb Stadtentwässerung Mannheim (owner-operated municipal drainage enterprise). Particular thanks go to Mr. Hein and his colleagues from Mannheim WWTP for their valuable collaboration.