Pilot-scale tests were run with ozonation for reduction of 24 pharmaceuticals at 10 full-scale wastewater treatment plants in southern Sweden. Reduction was evaluated based on doses of 3, 5 and 7 g O3/m3 at all plants. The reduction of pharmaceuticals reached on average 65% at 3 g O3/m3, 78% at 5 g O3/m3 and 88% for 7 g O3/m3 in terms of total concentration of pharmaceuticals. Specific ozone dose (ratio O3:TOC) was found to be highly influential on pharmaceutical removal. At two WWTPs, the pharmaceutical removal was severely reduced.

Many countries are considering the need for reduction of pharmaceuticals and other organic micropollutants in wastewater. In Switzerland the legal framework is already in place (Eggen et al. 2014), in the EU, the list of priority pollutants already include organic micropollutants and the ‘watch list’ has recently been extended with a number of pharmaceuticals (2013/39/EU). In Sweden, the first full-scale installation based on ozonation, is under construction (IVL 2016) even though the needs and requirements of such a treatment step are still debated.

Ozonation and activated carbon treatment, or a combination seems to be the winning technologies for reduction of organic micropollutants. Full-scale installations have only been reported in a few countries (Cimbritz et al. 2016) but pilot-scale installations have been running at several places in order to test the technology and to give guidelines for design (Hollender et al. 2009; Wert et al. 2009; Ibáñez et al. 2013; Margot et al. 2013). Such guidelines are problematic as long as the substances included in the control program and the limits and control methods are not selected at the same time. Typically, a number of substances in high concentration for which reasonable analytical methods exist are selected and the final effluent concentration or the percentage reduction is used as evaluation criteria (Huber et al. 2005; Hansen et al. 2010; Antoniou et al. 2013).

For design of equipment and estimation of the economy in ozonation, guidelines for the needed ozone dose is typically based on the content of organic material in the treated wastewater. As the major part of the ozone is consumed by organic matter left after the normal treatment only a minor part is used to oxidize micropollutants. In addition, pH, alkalinity and a number of substances that might be present in treated wastewater are known to have a significant impact on ozone consumption and consequently on the ozone dose needed (Gottschalk et al. 2010; Hansen et al. 2010; Antoniou et al. 2013; Hey et al. 2014).

The Swedish debate about the need for reduction of organic micropollutants, especially pharmaceuticals, might end up with a general requirement of wastewater treatment plants to include reduction of pharmaceuticals in the near future. Consequently, a deeper understanding of the expected need for ozone addition is required before the economic and environmental consequences can be evaluated. Testing at single treatment plants might not be representative for other WWTPs. Therefore, the main objective of the present study was to test whether ozone can be used in the same manner and reach comparable results in terms of pharmaceutical reduction regardless of the WWTP configuration. The secondary objective was to study how the concentration of TOC in the treated wastewater impacts the efficiency of pharmaceutical reduction and evaluate whether it can be used in a general model to control the amount of ozone being produced in a full-scale ozone installation.

Pilot plant

A schematic representation of the ozone equipment used throughout the trials is depicted in Figure 1. The objective of the system was to produce and dissolve ozone into wastewater in a measurable and repeatable way at 10 WWTPs. All equipment was housed in a 20 feet container. A submerged centrifugal pump delivered 18–20 m3/h of treated wastewater into a drum filter. The purpose of the drum filter was to reduce turbidity and minimize the impact of fluctuations in WWTP performance (such as an underperforming clarifier) on the ozone pilot plant. The flow entering the drum filter was monitored by a flow meter at the inlet. The reduction of turbidity across the filter was monitored by two turbidity meters positioned before and after the filter. Filtered wastewater entered a holding tank to equalize the flow before the ozone injection. The excess flow (about 12 m3/h) was discharged back into the wastewater stream, downstream of the submerged centrifugal pump.

Figure 1

Schematic overview of the equipment used. 1: Compressor (AirSep, Topaz Plus), 2: PSA oxygen supply (AirSep, Topaz Plus), 3: Chiller (Lauda, UC Mini), 4: Ozone generator (Primozone, GM2), 5: Ozone concentration meter (BMT, 964-C), 6: Submerged centrifugal pump (Mecana, TF2), 7: Flowmeter (Mecana, TF2), 8: Turbidity meter (Mecana, TF2), 9: Drum filter (Mecana, TF2), 10: Turbidity meter (Mecana, TF2), 11: 1 m3 equalization tank, 12: Booster pump (Grundfos, CM5-4), 13: Flow meter (Honsberg), 14: Venturi injector (Mazzei, 1583), 15: 500 l pressurized reaction vessel (HRT: 5 min), 16: Sludge from drum filter, 17: Excess flow, 18: Discharge from ozonation, 19: Main PLC (Schneider, Modicon M251).

Figure 1

Schematic overview of the equipment used. 1: Compressor (AirSep, Topaz Plus), 2: PSA oxygen supply (AirSep, Topaz Plus), 3: Chiller (Lauda, UC Mini), 4: Ozone generator (Primozone, GM2), 5: Ozone concentration meter (BMT, 964-C), 6: Submerged centrifugal pump (Mecana, TF2), 7: Flowmeter (Mecana, TF2), 8: Turbidity meter (Mecana, TF2), 9: Drum filter (Mecana, TF2), 10: Turbidity meter (Mecana, TF2), 11: 1 m3 equalization tank, 12: Booster pump (Grundfos, CM5-4), 13: Flow meter (Honsberg), 14: Venturi injector (Mazzei, 1583), 15: 500 l pressurized reaction vessel (HRT: 5 min), 16: Sludge from drum filter, 17: Excess flow, 18: Discharge from ozonation, 19: Main PLC (Schneider, Modicon M251).

Close modal

Ozone was produced from onsite generated oxygen. A main PLC was connected to the flow meter, ozone generator and ozone concentration meter, which enabled the ozone dose (displayed as g O3/m3 on the main PLC screen) to be monitored manually throughout the trials. The wastewater from the equalization tank (6 m3/h) was pumped with a booster pump through a venturi injector and mixed with the ozone, the flow of water being monitored by a flow meter. The ozonated wastewater then entered a pressurized reaction tank (5 min HRT at 6 m3/h) before being discharged back into the wastewater stream downstream of the submerged centrifugal pump. There were a total of 3 sampling locations, at the inlet of the drum filter (IN), after the filter (AF) and outlet (OUT) of the pressurized reaction tank.

Operation of the pilot plant

The trials were run in the same manner throughout all 10 WWTPs. The submerged pump was lowered into the discharge stream at the WWTP, wastewater was pumped through the system for at least 24 hours prior to the commencement of the trials. This was done to safeguard that no residuals from the previous trial were present.

The ozone production was started and adjusted manually until the production corresponded to the lowest ozone dose (3 g O3/m3 wastewater). After the ozone flow had reached the required dosage, it was kept running for 20 minutes (4× HRT) before the first samples were taken. Samples were collected in glass bottles from points IN (0.5 L), AF (0.5 L) and OUT (1.5 L) every 10 minutes for a total of 60 minutes which resulted in 3.5 L sample from point IN, 3.5 L from point AF and 10.5 L from point OUT (3 g O3/m3). The next ozone doses (5 and 7 g O3/m3 wastewater) were then introduced to the system in the same manner. The samples from points IN and AF were taken as composite samples for the entire trial run.

Analysis

All samples were analyzed in the lab at Lund University. The chemical analysis was conducted with a spectrophotometer (Hach-Lange DR 2800): COD (Hach-Lange, LCK 314), TOC (LCK 385), Tot-P (LCK 349), PO4-P (LCK 349), Tot-N (LCK 138), NH4-N (LCK 303), NO3-N (LCK 339), NO2-N (LCK 341). The other analysis were conducted using the standard procedures: SS (according to SS-EN 872:2005) and pH (WTW pH 320).

SUVA 254 measurement was conducted with a modification of the standard method published by USEPA (2005), absorbance was measured at 254 nm and the results were normalized with regards to TOC. The SS content in the samples taken from point OUT were so low that TOC can be regarded as dissolved organic carbon. SUVA 254 was not conducted for the first three WWTPs.

Samples were also sent to IVL (Swedish Environmental Research Institute) for pharmaceutical analysis (liquid chromatography-tandem mass spectrometry) were carried out in accordance with Gros et al. (2006). The pharmaceuticals analyzed are listed in Table 1.

Table 1

The 24 pharmaceuticals included in the analysis

NameTypeNameType
Amlodipine Antihypertensive Metoprolol Antihypertensive 
Atenolol Antihypertensive Naproxen Anti-inflammatory 
Bisoprolol Antihypertensive Oxazepam Sedative 
Caffeine Stimulant Paracetamol Anti-inflammatory 
Carbamazepine Sedative Propranolol Antihypertensive 
Ciprofloxacin Antibiotic Ranitidine Antiulcer 
Citalopram Antidepressant Sertralin Antidepressant 
Diclofenac Anti-inflammatory Sulfamethoxazole Antibiotic 
Furosemide Diuretic Terbutaline Asthma medication 
Hydrochlorothiazide Antihypertensive Tetracycline Antibiotic 
Ibuprofen Anti-inflammatory Trimetoprim Antibiotic 
Ketoprofen Anti-inflammatory Warfarin Anticoagulant 
NameTypeNameType
Amlodipine Antihypertensive Metoprolol Antihypertensive 
Atenolol Antihypertensive Naproxen Anti-inflammatory 
Bisoprolol Antihypertensive Oxazepam Sedative 
Caffeine Stimulant Paracetamol Anti-inflammatory 
Carbamazepine Sedative Propranolol Antihypertensive 
Ciprofloxacin Antibiotic Ranitidine Antiulcer 
Citalopram Antidepressant Sertralin Antidepressant 
Diclofenac Anti-inflammatory Sulfamethoxazole Antibiotic 
Furosemide Diuretic Terbutaline Asthma medication 
Hydrochlorothiazide Antihypertensive Tetracycline Antibiotic 
Ibuprofen Anti-inflammatory Trimetoprim Antibiotic 
Ketoprofen Anti-inflammatory Warfarin Anticoagulant 

Wastewater treatment plants

The trials were run at 10 different WWTPs in southern Sweden (Table 2), all designed for more than 10,000 PE. There are differences in the geographical location of the plants, as well as the configuration and industries connected to them. The plants are briefly described in Table 2.

Table 2

General description of the WWTPs in this trial.

WWTPPE (connected)BOD removalNitrificationDenitrificationSand filtration
Sternö 21,200 AS AS AS 
Sjöhög 33,900 AS AS AS  
Nyvångsverket 11,800 TF TF AS 
Torekov 12,900 AS AS AS  
Sjölunda 317,000 AS TF MBBR  
Källby 98,600 AS AS AS  
Ellinge 20,100 AS AS AS  
Kävlinge 29,000 AS AS AS 
Svedala 12,000 AS AS AS  
Västra Stranden 70,000 AS AS AS  
WWTPPE (connected)BOD removalNitrificationDenitrificationSand filtration
Sternö 21,200 AS AS AS 
Sjöhög 33,900 AS AS AS  
Nyvångsverket 11,800 TF TF AS 
Torekov 12,900 AS AS AS  
Sjölunda 317,000 AS TF MBBR  
Källby 98,600 AS AS AS  
Ellinge 20,100 AS AS AS  
Kävlinge 29,000 AS AS AS 
Svedala 12,000 AS AS AS  
Västra Stranden 70,000 AS AS AS  

AS: activated sludge, TF: trickling filter, MBBR: moving bed biofilm reactor. X in the final column denotes that the WWTP utilizes a sand filter

Sjölunda WWTP has an unusual implementation of BOD and nitrogen removal. A detailed description of the plant can be found in (Hanner et al. 2003). In short, BOD is removed in a high loaded activated sludge plant. Nitrification takes place in trickling filters with plastic carriers followed by denitrification in a two-stage MBBR system. Final separation takes place in a flotation plant.

Pharmaceuticals

There are at present no set concentration limits for specific pharmaceuticals within the EU. Therefore, the reduction of pharmaceuticals in this paper is presented as reduction of the total concentration of all analyzed pharmaceuticals. Furthermore, as there are no reduction criteria in use in the EU, the Swiss limit (Eggen et al. 2014) of 80% reduction of pharmaceuticals is designated as the target value.

The sum of all 24 pharmaceuticals is depicted in Table 3. If a pharmaceutical concentration was below the detection limit, the concentration of such compound was set to half the detection limit. The total concentration of pharmaceuticals that entered the pilot plant varied between 4,600 and 18,700 ng/L. As the analysis for pharmaceuticals were conducted on dissolved compounds only and no precipitating agents were employed, the drum filter is not considered to have had any impact on the pharmaceutical removal in these trials.

Table 3

Sum of the pharmaceutical concentrations (ng/L) at points IN and OUT at the 10 WWTPs.

WWTPINOUT
Ozone dose
3 g O3/m35 g O3/m37 g O3/m3
Sternö 10,651 5,064 2,505 1,093 
Sjöhög 15,321 9,270 3,487 1,418 
Nyvångsverket 8,359 2,284 1,597 674 
Torekov 4,603 1,223 458 240 
Sjölunda 12,420 2,969 2,027 860 
Källby 12,095 2,308 1,048 711 
Ellinge 17,860 6,680 5,040 1,953 
Kävlinge 10,896 2,253 640 472 
Svedala 18,702 10,189 10,258 6,283 
Västra Stranden 7,838 2,453 2,156 1,683 
WWTPINOUT
Ozone dose
3 g O3/m35 g O3/m37 g O3/m3
Sternö 10,651 5,064 2,505 1,093 
Sjöhög 15,321 9,270 3,487 1,418 
Nyvångsverket 8,359 2,284 1,597 674 
Torekov 4,603 1,223 458 240 
Sjölunda 12,420 2,969 2,027 860 
Källby 12,095 2,308 1,048 711 
Ellinge 17,860 6,680 5,040 1,953 
Kävlinge 10,896 2,253 640 472 
Svedala 18,702 10,189 10,258 6,283 
Västra Stranden 7,838 2,453 2,156 1,683 

Figure 2 shows the total pharmaceutical removal at the three applied ozone doses. On average, the total concentration of measured pharmaceuticals was reduced by 65% at 3 g O3/m3, 78% at 5 g O3/m3 and 88% at 7 g O3/m3. However, these figures are the average removal from all the WWTPs, if the last two WWTPs were to be removed from consideration, said figures reaches 67%, 83% and 92% for 3, 5 and 7 g O3/m3 doses. This increase in averages points to the impact of the lower removal at Svedala and Västra Stranden and elicits further analysis, as something clearly caused the pharmaceutical removal to be less effective at those WWTPs. In the case of Svedala WWTP, the total concentration of pharmaceuticals entering the pilot plant reached 18,702 ng/L which is the highest of all the WWTPs, however, it is considered to be comparable to Ellinge WWTP at 17,860 ng/L. Furthermore, the inlet concentration to the pilot plant at Västra Stranden (7,838 ng/L) is comparable to Nyvångsverket WWTP (8,359 ng/L).

Figure 2

Total pharmaceutical removal at the three ozone doses (3, 5 and 7 g O3/m3).

Figure 2

Total pharmaceutical removal at the three ozone doses (3, 5 and 7 g O3/m3).

Close modal

Thus, the inlet concentrations of pharmaceuticals at Svedala and Västra Stranden are not considered to be responsible for the lower reduction at those plants. When applying the criteria set for removal of pharmaceuticals (>80%), 3 g O3/m3 is sufficient only at two WWTPs (Källby and Kävlinge). At 5 g O3/m3 the number of plants reaching the criteria increases to 5 (Nyvång, Torekov, Sjölunda, Källby and Kävlinge). At 7 g O3/m3 all but the last two WWTPs reaches 80% removal.

The pharmaceutical compounds are divided into groups in Table 4. The compounds which were removed above 80% at more than 6 WWTPs are grouped according to the ozone dose required to reach that criteria. The column ‘Removed <80% or at <6 plants’ contains the pharmaceuticals which were not removed above 80% or removed above 80% but in fewer than 6 WWTPs and are considered difficult to remove. The last column contain the pharmaceuticals that were not found in sufficient concentration at sufficient number of WWTPs. The average relative inlet concentration of the compound groups (%) are listed at the bottom of each group.

Table 4

Individual pharmaceuticals divided into groups depending on to which extent they were removed.

Removed at 3 g O3/m3Removed at 5 g O3/m3Removed at 7 g O3/m3Removed <80% or at <6 plantsNot found in sufficient concentration
Diclofenac Citalopram Hydrochlorothiazide Ibuprofen Ciprofloxacin 
Furosemide  Sulfamethoxazole Warfarin Tetracycline 
Naproxen  Atenolol Caffeine Amlodipine 
Carbamazepine  Bisoprolol Ketoprofen  
Propranolol  Metoprolol Oxazepam  
Ranitidine  Sertralin Paracetamol  
   Terbutaline  
   Trimetoprim  
33% 2.8% 36.7% 26.5% 1.5% 
Removed at 3 g O3/m3Removed at 5 g O3/m3Removed at 7 g O3/m3Removed <80% or at <6 plantsNot found in sufficient concentration
Diclofenac Citalopram Hydrochlorothiazide Ibuprofen Ciprofloxacin 
Furosemide  Sulfamethoxazole Warfarin Tetracycline 
Naproxen  Atenolol Caffeine Amlodipine 
Carbamazepine  Bisoprolol Ketoprofen  
Propranolol  Metoprolol Oxazepam  
Ranitidine  Sertralin Paracetamol  
   Terbutaline  
   Trimetoprim  
33% 2.8% 36.7% 26.5% 1.5% 

The first two groups in Table 4 (‘Removed at 3 g O3/m3’ and ‘Removed at 5 g O3/m3’) corresponds reasonably well with the findings of Antoniou et al. (2013) and Margot et al. (2013). The last two groups (‘Removed at 7 g O3/m3’ and ‘Removed <80% or at <6 plants') corresponds well with the findings of Hey et al. (2014) and Hollender et al. (2009).

The average removal of individual pharmaceutical compounds is depicted in Figure 3 along with the standard deviation of each compound. As ciproflaxin, tetracycline and amlodipine were only found in a handful of WWTPs they are excluded from the graph.

Figure 3

Average pharmaceutical removal of individual pharmaceutical compounds at all 10 WWTPs.

Figure 3

Average pharmaceutical removal of individual pharmaceutical compounds at all 10 WWTPs.

Close modal

As is apparent from Figure 3, the standard deviation is quite large for some of the pharmaceutical compounds, especially at the lowest ozone dose (3 g O3/m3). For instance, ibuprofen exhibits a standard deviation of 38% at the lowest ozone dose. The reason for this rather large standard deviation is unknown, however, it is not surprising since the trials were conducted in pilot-scale at several WWTPs with varying wastewaters.

A radar chart of the removal of diclofenac, from the group ‘Removed at 3 g O3/m3’ in Table 4 is depicted in Figure 4. Diclofenac is removed completely at all WWTPs at the lowest ozone dose except at Svedala and Västra Stranden, where it takes an ozone dose of 7 g O3/m3 to remove this compound with more than 80%.

Figure 4

Radar chart of the removal of diclofenac at 10 WWTPs.

Figure 4

Radar chart of the removal of diclofenac at 10 WWTPs.

Close modal

The removal of citalopram (from the group ‘Removed at 5 g O3/m3’ in Table 4) is depicted in Figure 5. This compound was not found in Västra Stranden so that WWTP is excluded from this chart. An ozone dose of 5 g O3/m3 is required to remove this compound above 80% at all plants except Svedala where it is not removed above 40% at any ozone dose.

Figure 5

Radar chart of the removal of citalopram at 9 WWTPs.

Figure 5

Radar chart of the removal of citalopram at 9 WWTPs.

Close modal

When the removal of hydrochlorothiazide (from the group ‘Removed at 7 g O3/m3’ in Table 4) is plotted in the same way (Figure 6) it becomes apparent that the more difficult a compound is to remove the larger the variations in removal becomes. For instance, in both Nyvångsverket and Torekov this compound is removed by 80% with the lowest ozone dose (3 g O3/m3). Whereas in Sternö, Sjöhög, Sjölunda and Ellinge the lowest ozone dose does not remove this compound to more than 40%. None of the ozone doses were sufficient to remove hydrochlorothiazide at neither Svedala nor Västra Stranden.

Figure 6

Radar chart of the removal of hydrochlorothiazide of at 10 WWTPs.

Figure 6

Radar chart of the removal of hydrochlorothiazide of at 10 WWTPs.

Close modal

In most of the samples, the increasing dose of ozone (3 to 7 g O3/m3) oxidized nitrite to below the detection limit. As ozone reacts well with nitrite this was not unexpected, however, the samples from Svedala and Västra Stranden did not show the same trend and nitrite was still measurable after ozonation. The lack of nitrite oxidation at those plants indicates that ozone scavenging took place. The ingoing nitrite concentrations were so low at those plants (0.14 for Svedala and 0.09 mg/L for Västra Stranden) that the nitrite is not considered to be the reason for the poor removal of pharmaceuticals.

COD and TOC

COD was measured in all samples and ranged between 21 mg/L and 35 mg/L, but since COD analysis is not in general available in Sweden anymore TOC is used instead. The concentration of total organic carbon discharged from the WWTPs (Table 5), ranged between 8.4 and 13.9 mg TOC/L. Ozone did remove some of the TOC albeit not to a high degree.

Table 5

TOC measurements (mg TOC/L) in points IN, AF and OUT at the 10 WWTPs.

WWTPIN (mg/L)AF (mg/L)OUT
Ozone dose
3 g O3/m35 g O3/m37 g O3/m3
Sternö 13.9 a 13.9 13.5 13.4 
Sjöhög 10.6 a 10.1 9.8 9.9 
Nyvångsverket 11.4 a 8.1 8.1 8.1 
Torekov 9.5 8.7 8.5 8.6 8.4 
Sjölunda 11.0 10.8 9.3 10.6 9.9 
Källby 9.8 8.9 8.1 8.0 8.2 
Ellinge 13.1 13.1 12.9 12.5 12.5 
Kävlinge 8.4 8.2 7.3 7.7 7.4 
Svedala 13.3 12.3 12.7 12.5 12.5 
Västra Stranden 11.4 11.4 10.9 10.8 11.0 
WWTPIN (mg/L)AF (mg/L)OUT
Ozone dose
3 g O3/m35 g O3/m37 g O3/m3
Sternö 13.9 a 13.9 13.5 13.4 
Sjöhög 10.6 a 10.1 9.8 9.9 
Nyvångsverket 11.4 a 8.1 8.1 8.1 
Torekov 9.5 8.7 8.5 8.6 8.4 
Sjölunda 11.0 10.8 9.3 10.6 9.9 
Källby 9.8 8.9 8.1 8.0 8.2 
Ellinge 13.1 13.1 12.9 12.5 12.5 
Kävlinge 8.4 8.2 7.3 7.7 7.4 
Svedala 13.3 12.3 12.7 12.5 12.5 
Västra Stranden 11.4 11.4 10.9 10.8 11.0 

aNo results available due to lacking samples.

A closer look at the TOC figures reveals that the TOC values for Svedala and Västra Stranden WWTPs are not so high as to explain the discrepancy in pharmaceutical removal at those plants.

SUVA 254 nm

The SUVA 254 values are depicted in Figure 6. A decline in SUVA 254 can be considered to be an indicator of increasing pharmaceutical removal as well as a decline in the total concentration of aromatic substances (Wittmer et al. 2015). The majority of the SUVA 254 values in Figure 7 declines as the ozone dose increases. The SUVA 254 results obtained from Svedala follow the same trend as the other WWTPs, however, with a much lower reduction of aromatics at the higher ozone doses. In Västra Stranden, the SUVA 254 does not decline at all even at 7 g O3/m3. The behavior displayed at Västra Stranden WWTP indicates that ozone scavenging took place to a high degree.

Figure 7

The specific UV absorbance at 254 nm at the different measuring points.

Figure 7

The specific UV absorbance at 254 nm at the different measuring points.

Close modal

Pharmaceutical removal as a function of TOC

The relationship between TOC and pharmaceutical removal is depicted in Figure 8. TOC and ozone dose are combined into specific ozone dose (ratio O3:TOC).

Figure 8

A combined graph of specific ozone dose (ratio O3:TOC) and pharmaceutical removal.

Figure 8

A combined graph of specific ozone dose (ratio O3:TOC) and pharmaceutical removal.

Close modal

As the ratio of ozone to TOC increases so does the pharmaceutical removal. The removal efficiency increases rapidly when O3:TOC is increased from approximately 0.2 to 0.4 after which the total removal levels off. This overall behavior is not surprising as the compounds which are easily removed (removed at 3 and 5 g O3/m3, Table 4) are removed well above 80% at the lower doses (O3:TOC 0.2–0.4). Followed by the more difficult compounds (removed at 7 g O3/m3 and Removed <80% and/or at <6 plants, Table 4) which requires a higher specific ozone dose, eventually leaving only the compounds which are not susceptible to ozone oxidation in this range of ozone doses. The spread in the data points at the lower region (O3:TOC 0.2–0.4) is quite substantial while being more clustered together in the higher region (O3:TOC 0.4–0.8).

The apparent trend seen in Figure 8 can be useful in the early stages when an ozone system is to be sized. However, the high degree of spread between the data points (especially between O3:TOC 0.2–0.4) and the low number of samples (3 samples at 10 WWTPs) points to that further testing is needed before the ratio O3:TOC can be used as an online control parameter in full-scale. However, if tests were to be performed at one WWTP instead of 10 and run for a longer time, it is very likely that a model of how specific ozone dose impacts pharmaceutical removal could be found for that specific WWTP.

In these trials, the only ozone dose able to meet the >80% removal criteria at a majority (8 out of 10) of the plants is 7 g O3/m3. A detailed cost calculation has not been made for this paper. However, a recent publication by Mulder et al. (2015) calculated the cost of running an ozone installation with a dose of 7.7 g O3/m3 to 0.16 €/m3 treated wastewater (±0.03 €) for a 300,000 p.e. WWTP. The cost of running a comparable PAC (powdered activated carbon) installation reached 0.18 €/m3 (±0.03 €) treated wastewater (Mulder et al. 2015).

Svedala and Västra Stranden WWTPs

The removal of pharmaceuticals was in general quite high when excluding the last two WWTPs. However, when the last two WWTPs are included, the averages drops significantly. The fact that nitrite was detected in the samples from these plants after ozonation was surprising since nitrite is highly reactive with ozone. Therefore, the most probable reasons for the lower pharmaceutical reduction at these plants are either an equipment failure leading to lower ozone doses or ozone scavenging of an unknown compound. No failures of the ozone equipment was detected at either of these trial runs which enhances the probability of an unknown ozone scavenging compound.

The main purpose of the pilot-scale trials was to evaluate the practical application of ozone at different WWTPs without considering the differences at the plants. A criteria of 80% total removal of pharmaceuticals was established as a benchmark. This criteria was met at all WWTPs at 7 g O3/m3 except at Svedala and Västra Stranden, therefore the process can be said to remove pharmaceuticals efficiently and with reasonably comparable results but only at the higher ozone doses. The reason for the lower removal efficiency at Svedala and Västra Stranden WWTPs was not found.

A link between specific ozone dose (ratio O3:TOC) and pharmaceutical removal efficiency was found to exist but it is not accurate enough to be integrated as a parameter to control the output of ozone as of yet. Further work is clearly needed to acquire a general model which can be implemented at any WWTP.

This work was financially supported by: The Swedish Water & Wastewater Association through VA-teknik Södra, Tillväxtverket, Primozone Production AB and the municipalities of Karlshamn, Ystad, Malmö, Lund, Kävlinge, Halmstad, Svedala, Eslöv, Åstorp and Båstad. The authors thank all who participated in the study and wish to extend special thanks to the personnel at the WWTPs who made this study possible.

Antoniou
,
M. G.
,
Hey
,
G.
,
Vega
,
S. R.
,
Spiliotopoulou
,
A.
,
Fick
,
J.
,
Tysklind
,
M.
,
la Cour Jansen
,
J.
&
Andersen
,
H. R.
2013
Required ozone doses for removing pharmaceuticals from wastewater
.
Science of the Total Environment
456–457
,
42
49
.
Cimbritz
,
M.
,
Tumlin
,
S.
,
Hagman
,
M.
,
Dimitrova
,
I.
,
Hey
,
G.
,
Mases
,
M.
,
Åstrand
,
N.
&
la Cour Jansen
,
J.
2016
Treatment of Pharmaceutical Residues and Other Micropollutants – a Literature Survey. Report 2016-04
.
Svenskt Vatten AB
,
Stockholm
.
Eggen
,
R. I. L.
,
Hollender
,
J.
,
Joss
,
A.
,
Schärer
,
M.
&
Stamm
,
C.
2014
Reducing the discharge of micropollutants in the aquatic environment: the benefits of upgrading wastewater treatment plants
.
Environmental Science & Technology
48
,
7683
7689
.
EU/2013/39, OJ L 226, 24.8.2013
, pp.
1
17
.
Gottschalk
,
C.
,
Libra
,
J. A.
&
Saupe
,
A.
2010
Ozonation of Water and Wastewater – A Practical Guide to Understanding Ozone and its Application
, 2nd edn.
Wiley-VCH Verlag GmbH & Co. KGaA
,
Weinheim
.
Hanner
,
N.
,
Aspegren
,
H.
,
Nyberg
,
U.
&
Andersson
,
B.
2003
Upgrading the Sjölunda WWTP according to a novel process concept
.
Water Science & Technology
47
(
12
),
1
7
.
Hansen
,
K. M. S.
,
Andersen
,
H. R.
&
Ledin
,
A.
2010
Ozonation of estrogenic chemicals in biologically treated sewage
.
Water Science & Technology
62
(
3
),
649
657
.
Hey
,
G.
,
Vega
,
S. R.
,
Fick
,
J.
,
Tysklind
,
M.
,
Ledin
,
A.
,
la Cour Jansen
,
J.
&
Andersen
,
H. R.
2014
Removal of pharmaceuticals in WWTP effluents by ozone and hydrogen peroxide
.
Water SA
40
(
1
),
1
10
.
Hollender
,
J.
,
Zimmermann
,
S. G.
,
Koepke
,
S.
,
Krauss
,
M.
,
Mcardell
,
C. S.
,
Ort
,
C.
,
Singer
,
H.
,
Von Gunten
,
U.
&
Siegrist
,
H.
2009
Elimination of organic micropollutants in a municipal wastewater treatment plant upgraded with a full-scale post-ozonation followed by sand filtration
.
Environmental Science & Technology
43
,
7862
7869
.
Huber
,
M. M.
,
Göbel
,
A.
,
Joss
,
A.
,
Hermann
,
N.
,
Löffler
,
D.
,
Mcardell
,
C. S.
,
Ried
,
A.
,
Siegrist
,
H.
,
Ternes
,
T. A.
&
von Gunten
,
U.
2005
Oxidation of pharmaceuticals during ozonation of municipal wastewater effluents: a pilot study
.
Environmental Science & Technology
39
,
4290
4299
.
Ibáñez
,
M.
,
Gracia-Lor
,
E.
,
Bijlsma
,
L.
,
Morales
,
E.
,
Pastor
,
L.
&
Hernández
,
F.
2013
Removal of emerging contaminants in sewage water subjected to advanced oxidation with ozone
.
Journal of Hazardous Materials
260
,
389
398
.
IVL
2016
Sweden's first purification plant for removal of wastewater pharmaceutical residues under construction. IVL news bulletin. http://www.ivl.se. 30th of November (accessed 25 January 2017)
.
Margot
,
J.
,
Kienle
,
C.
,
Magnet
,
A.
,
Weil
,
M.
,
Rossi
,
L.
,
de Alencastro
,
L. F.
,
Abegglen
,
C.
,
Thonney
,
D.
,
Chèvre
,
N.
,
Schärer
,
M.
&
Barry
,
D. A.
2013
Treatment of micropollutants in municipal wastewater: ozone or powdered activated carbon?
Science of the Total Environment
461–462
,
430
498
.
Mulder
,
M.
,
Antakyali
,
D.
&
Ante
,
S.
2015
Costs of Removal of Micropollutants From Effluents of Municipal Wastewater Treatment Plants – General Cost Estimates for the Netherlands Based on Implemented Full Scale Post Treatments of Effluents of Wastewater Treatment Plants in Germany and Switzerland
.
STOWA and Waterboard the Dommel
,
Netherlands
.
SS-EN 872:
2005
Water quality - Determination of suspended solids - Method by filtration through glass fiber filters (In Swedish)
.
USEPA.
2005
Determination of total organic carbon and specific UV absorbance at 254 nm in source water and drinking water. USEPA Document # EPA/600/R-05/055
.
Wert
,
E. C.
,
Rosario-Ortiz
,
F.
&
Snyder
,
S. A.
2009
Effect of ozone exposure on the oxidation of trace organic contaminants in wastewater
.
Water Research
43
,
1005
1014
.
Wittmer
,
A.
,
Heisele
,
A.
,
Mcardell
,
C. S.
,
Böhler
,
M.
,
Longree
,
P.
&
Siegrist
,
H.
2015
Decreased UV absorbance as an indicator of micropollutant removal efficiency in wastewater treated with ozone
.
Water Science & Technology
71
(
7
),
980
985
.