Quantity and quality of raw domestic wastewater are reviewed and discussed for packaged plants, known as johkasou, in Japan. A method for the estimation of johkasou capacity in terms of population equivalent, or PE, was introduced and discussed in this paper. It was found that the pollutant loads of domestic wastewater were respectively BOD 45 g, CODMn 23 g, SS 37 g, TN 9.3 g and TP 1.1 g per capita per day on average. It shows that the BOD load of wastewater from kitchens is higher than that of black water. The estimation of the johkasou capacity needed for buildings can be done using a series of formulas, which forms an important estimation method for the implementation of on-site wastewater treatment.

The quantity and quality of raw domestic wastewater are essential for the design, operation and maintenance of wastewater treatment plants. In the case of small wastewater treatment plants for decentralized sanitation or the so-called packaged plants, they are designed and tested under the condition of a designated quantity and pollutant loads from raw domestic wastewater in most developed countries. To ensure that a packaged plant functions well as designed, the installation of a plant with sufficient capacity for the target house/building is necessary. In many cases, the quantity and pollutant loads of a new building need to be estimated to determine a packaged plant with appropriate capacity. It is important to identify the quantity and quality of the raw domestic wastewater of houses and buildings with different uses.

In Japan, there are three major systems for domestic wastewater treatment, which can be classified into ‘sewerage system’, ‘johkasou system’ and ‘rural sewerage system’. Johkasou, a type of packaged plant, has been introduced and developed originally to meet the needs of the flush toilets of individual households in the suburban and rural areas in the early 1960s.

Johkasou in general are prefabricated products installed in the yard of houses, which treat domestic wastewater up to a high level of water quality (Figure 1). Different from septic tanks, johkasou are small-scale wastewater treatment plants with a very small capacity, directly discharging the effluent into the surrounding water bodies, instead of infiltrating wastewater into the ground. To ensure normal treatment performance, johkasou are appropriately designed, tested, installed and maintained by certified technicians of johkasou businesses following various technical and administrative regulations. However, the treatment performance of johkasou may become unsteady when the pollutant loads of raw domestic wastewater are beyond the johkasou capacity of treatment. Therefore, it is important to identify the quantity and quality of wastewater and select a johkasou with appropriate capacity in accordance with the pollutant loads it receives.

Figure 1

Schematics of household johkasou.

Figure 1

Schematics of household johkasou.

Close modal

In this paper, the quantity and quality of domestic wastewater and a method for the estimation of the population for johkasou from buildings for decentralized treatment were reviewed and discussed.

Methods of sampling and analyzing

Most of the data on quantity and quality of raw domestic wastewater used in this paper are obtained by on-site sampling from individual houses.

The normal procedures of sampling could be described as follows: (1) Collect every hour all of the discharged raw wastewater from the house, take two liters of raw wastewater as a sample, measure and record the amount of the raw wastewater discharged; (2) take samples in the same way for 24 hours; (3) make composite samples according to the amount of raw wastewater discharged hourly; and (4) perform water quality analyses of the composite samples.

Analysis methods

The composite samples were analyzed using an analysis method for wastewater stipulated by the Japanese Industrial Standards (JIS K 0102). The samples were analyzed to measure the concentrations of biological oxygen demand (BOD), chemical oxygen demand (CODMn), suspended solids (SS), total nitrogen (TN), total phosphorus (TP) and other items. The pollutant load of each item was obtained by multiplying its concentration with the amount of wastewater.

Quantity of water and wastewater

As the quantity of wastewater discharged basically depends on tap water consumption, it is important to identify the consumption of tap water in houses. A survey (Horio 2001) was carried out on the consumption of tap water over a period of 24 hours for 10 families. The survey results are shown in Figure 2.

Figure 2

Water quantity used from different family sizes.

Figure 2

Water quantity used from different family sizes.

Close modal

The water quantity was found to vary from 113 to 333 L/cap.day, while the average was 245 L/cap.day. Although the family size of each house is quite different, there seems to be little correlation between the water quantity and the family size.

The data of surveys (Kawamura 2013) on the tap water consumption of houses, which have been carried out every five years by the Tokyo Metropolitan authority over a period of 20 years, show that tap water consumption rates were 220 L/cap.day in 1987, 246 L/cap.day in 1992, 248 L/cap.day in 1997, 244 L/cap.day in 2002 and 239 L/cap.day in 2007, respectively. The fluctuations of the tap water consumption rate varies across a small range, and could be attributed to changes of lifestyle, such as the popularization of new appliances and water-saving trends in recent decades.

A comparison (Kawamura 1995) of wastewater quantity was made and is shown in Figure 3. The data obtained before 1990 show an average of 230 L/cap.day, while after 1990 a rate of 255 L/cap.day is seen. Some other surveys (Fujimura 2006) done in the 1970s and 1980s show that wastewater quantity averaged 229 L/cap.day during that period. These results show that the amount of wastewater discharged from houses increased slowly and varied across a very small range.

Figure 3

Water quantity obtained in different periods.

Figure 3

Water quantity obtained in different periods.

Close modal

The detail of wastewater quantity at generation source is summarized and shown in Table 1 (Kawamura 2013). The wastewater quantity varies from 244 to 265 L/cap.day. The wastewater discharged from flush toilets varies from 36 to 68 L/cap.day, 19–28% of the total amount. Among the generation sources outside flush toilets, the largest proportion of wastewater comes from bathing, accounting for 24–35%, and is then followed by laundry for 17–33%, cooking for 10–23%, and other activities for 3–8%.

Table 1

Quantity of domestic wastewater L/cap.day

Generation sourceOgawa & Tadokoro (2001) 
Kawamura (1995) Tokyo Metropolitan Government Bureau of Waterworks (1997) 
Tokyo Metropolitan Government Bureau of Waterworks (2002) 
%LL%L%L
Flush toilets 19 50 36–46 24 59 28 68 
Cooking 10 27 43–55 22 55 23 56 
Laundry 33 87 50–64 20 50 17 41 
Bathing 35 92 48–62 26 64 24 59 
Others 8.5 7–17 20 20 
Total 100 265  100 248 100 244 
Generation sourceOgawa & Tadokoro (2001) 
Kawamura (1995) Tokyo Metropolitan Government Bureau of Waterworks (1997) 
Tokyo Metropolitan Government Bureau of Waterworks (2002) 
%LL%L%L
Flush toilets 19 50 36–46 24 59 28 68 
Cooking 10 27 43–55 22 55 23 56 
Laundry 33 87 50–64 20 50 17 41 
Bathing 35 92 48–62 26 64 24 59 
Others 8.5 7–17 20 20 
Total 100 265  100 248 100 244 

Pollutant loads

The pollutant loads of domestic wastewater obtained in previous studies (Imura 1994; Inamori et al. 1998; Ogawa & Tadokoro 2001; Ishihara et al. 2006), which were carried out from the 1970s to the 2000s, are summarized in Tables 2 and 3.

Table 2

Pollutant loads of domestic wastewater g/cap.day

Fujimura (2006) Inamori et al. (1998) Kawamura (1995) Ogawa & Tadokoro (2001) Ishihara et al. (2006) Inamori et al. (2006) Imura (1994) MOE (2006) MOE (2006) Avg.
BOD 45 43 47 47 46 36.6 58 50 32.5 41.4 45 
CODMn 23 24 27 22 – 12.2 27 25 – – 23 
SS – – 47 35 – 22.7 45  – – 37 
TN 8.1 8.6 12.5 8.5 6.6 – 11 10 – – 9.3 
TP 0.9 1.2 1.8 1.0 0.8 – 1.3 1.0 – – 1.1 
Fujimura (2006) Inamori et al. (1998) Kawamura (1995) Ogawa & Tadokoro (2001) Ishihara et al. (2006) Inamori et al. (2006) Imura (1994) MOE (2006) MOE (2006) Avg.
BOD 45 43 47 47 46 36.6 58 50 32.5 41.4 45 
CODMn 23 24 27 22 – 12.2 27 25 – – 23 
SS – – 47 35 – 22.7 45  – – 37 
TN 8.1 8.6 12.5 8.5 6.6 – 11 10 – – 9.3 
TP 0.9 1.2 1.8 1.0 0.8 – 1.3 1.0 – – 1.1 
Table 3

Pollutant loads of domestic wastewater at generation sources g/cap.day

Generation sourceFujimura (2006) 
Kawamura (1995) 
MOE (2006) 
MOE (2006) 
BODCODMnT-NT-PBODT-NT-PBODBOD
Flush toilets 16.0 10.0 7.0 0.70      
Cooking     25.4 0.80 0.100 16.8 21.0 
Laundry     5.0 0.20 0.010 3.9 4.0 
Bathing     2.9 0.35 0.029 9.1 1.5 
Others     0.8 0.32 0.069 0.7 0.5 
Total 16.0 10.0 7.0 0.7 34.1 1.7 0.208 30.5 27.0 
Generation sourceFujimura (2006) 
Kawamura (1995) 
MOE (2006) 
MOE (2006) 
BODCODMnT-NT-PBODT-NT-PBODBOD
Flush toilets 16.0 10.0 7.0 0.70      
Cooking     25.4 0.80 0.100 16.8 21.0 
Laundry     5.0 0.20 0.010 3.9 4.0 
Bathing     2.9 0.35 0.029 9.1 1.5 
Others     0.8 0.32 0.069 0.7 0.5 
Total 16.0 10.0 7.0 0.7 34.1 1.7 0.208 30.5 27.0 

The pollutant loads of domestic wastewater in terms of BOD vary from 32.5 g to 58 g while the average is 45 g/cap.day. The averages of CODMn, SS, TN and TP are 23 g, 37 g, 9.3 g and 1.1 g per capita per day, respectively, as shown in Table 2.

The pollutant loads of raw domestic wastewater in other countries have been reported by Henze & Ledin (2001). It was found that the BOD loads were estimated to be 82–96 g/cap.day in the USA, 55–82 g/cap.day in Denmark, Italy and Sweden, 55–68 g/cap.day in Brazil, and 27–41 g/cap.day in Egypt and Turkey; while the TN loads were 13.6–19.2 g/cap.day in the USA and 8.2–16.4 g/cap.day in other countries. It seems that the BOD loads of the raw domestic wastewater in Japan are inferior to those of European countries, Brazil and the USA, but are higher than those of Egypt and Turkey. The difference in the figures may partly be due to the different diets and lifestyle between the countries.

The pollutant loads generated at sources are shown in Table 3. It was found that most of the BOD loads come from cooking and black water, which account for more than 70–88% of the total. It also shows that the BOD loads of wastewater from kitchen are higher than that of black water. As for the pollutant loads of nitrogen and phosphorus, black water contains 80% of the nitrogen load and 77% of the phosphorus load. The BOD loads of gray water range from 30.5 to 34.1 g/cap.day, thus being much higher than that of black water. It is therefore important to treat both black and gray water to prevent water pollution in public waters.

Wastewater with high pollutant loads

Food waste disposers (hereafter, ‘FWD’) have recently spread in urban areas of Japan. Wastewater from FWDs should be treated individually by a treatment plant to a level acceptable by regulations. A new type of johkasou capable of treating both normal domestic wastewater and FWD wastewater has been developed. In this case, it is important to design a johkasou capable of treating the amount and pollutant loads of FWD wastewater.

Some results on pollutant loads due to FWD use are shown in Table 4. The pollutant loads of FWD were found to be 3.7 L for water quantity, 16–24 g for BOD, 5–19.7 g for CODMn, 7–16.1 g for SS, 0.5–2.1 g for nitrogen and 0.1–0.3 g for phosphorus per capita per day, which were measured through field researches.

Table 4

Quantity and quality of FWD wastewater g/cap.day

Water Quant.BODCODMnSST-NT-P
Survey 1 3.7 L 16.0 14.0 14.0 0.7 0.10 
Survey 2  17.3 19.7 16.1 0.9 – 
Survey 3  16–24 5–9 7–15 0.5–2.1 0.1–0.3 
Standard method 5 L 25 – 25 1.0 0.25 
Water Quant.BODCODMnSST-NT-P
Survey 1 3.7 L 16.0 14.0 14.0 0.7 0.10 
Survey 2  17.3 19.7 16.1 0.9 – 
Survey 3  16–24 5–9 7–15 0.5–2.1 0.1–0.3 
Standard method 5 L 25 – 25 1.0 0.25 

Pollutant loads by the standard method are obtained by grinding 250 g of standard food waste with 5 L of water by a FWD. For johkasou the pollutant loads are adopted as nominal loads. However, the nominal BOD and SS loads are much higher than those obtained in the surveys.

General

When a new building is planned and a johkasou is required to be constructed for treating the domestic water that will be discharged by the building, a johkasou with appropriate capacity must be selected according to the uses and the characteristics of the building, using a Japanese standard called ‘JIS A 3302:2000 Estimation of Population for Johkasou of Buildings’.

This standard specifies the methods for determining the capacity of johkasou in terms of ‘population equivalent’ (hereafter, ‘PE’), for buildings of different uses. The term PE used in this standard means that the amount of wastewater and pollutant loads for a building are expressed in a unit of PE. In the case of living accommodations, one PE, as shown in Table 5, is equal to 200 L/cap.day of wastewater and 40 g/cap.day of BOD loads discharged from the building. In other words, this is a kind of equivalent way of calculating pollutant loads for buildings of different uses and applying them, such as for those in residential areas. In most cases, the number of PE is not the occupancy load limit or the number of users of a building. Furthermore, in the cases of buildings for commercial uses, it is recommended that the values adopted for the water quantity and BOD load per PE differ from that of living accommodations. Data of unit loading per PE for buildings of different uses are shown in Table 5.

Table 5

Building uses defined in JIS A 3302:2000 (partly) and unit loading for buildings

Categoryper PE
W.Q. (L)BOD (g)
I Public facility 
 Public meeting places, theaters, cinemas 200 30 
 Horse/Bicycle/Motorboat Racetrack 150 40 
 Gymnasiums, sports stadiums 155 40 
II Living accommodation 
 Individual house 200 40 
 Residential complexes 200 40 
 Lodging houses and dormitory 200 28 
 School dormitory houses, nursery homes, 200 40 
III Accommodation facility 
 Hotels with wedding halls 200 40 
  without wedding halls 400 40 
 Motels 200 30 
 Hostels 200 40 
IV Medical facility 
 Hospital with kitchens and/or laundry services 125 40 
   less than 300 beds 125 40 
   more than 300 beds 113 36 
  without kitchens and/or laundry services 
   less than 300 beds 200 30 
   more than 300 beds 182 27 
 Small hospitals 130 40 
V Shops, stores 
 Stores, supermarkets 200 30 
 Departmental stores 200 30 
 Restaurants 
  normal pollutant loads 180 40 
  high pollutant loads 90 40 
  low pollutant loads 200 40 
 Coffee/tea houses 200 30 
VI Amusement facility 
 Disco houses 200 30 
 Bowling houses 200 30 
 Amusement parks 150 40 
 Camp sites 125 40 
 Golf courses 250 26 
VII Parking facility 
 Expressway rest areas 135 40 
 Parking facility 200 40 
 Gas station 200 40 
VIII Schools 
 Preschools, elementary schools, junior high schools 200 36 
 High schools, universities, colleges 200 36 
 Libraries 200 30 
IV Offices 
 Offices with kitchen equipment 200 40 
 without kitchen equipment 270 40 
Workplaces 
 Factories, institutes, laboratories 
  with kitchen equipment 133 30 
  without kitchen equipment 200 40 
XI Others 
 Markets 200 40 
 Public bathhouses 200 10 
 Public toilet facility 200 40 
 Stations, bus terminals 200 40 
Categoryper PE
W.Q. (L)BOD (g)
I Public facility 
 Public meeting places, theaters, cinemas 200 30 
 Horse/Bicycle/Motorboat Racetrack 150 40 
 Gymnasiums, sports stadiums 155 40 
II Living accommodation 
 Individual house 200 40 
 Residential complexes 200 40 
 Lodging houses and dormitory 200 28 
 School dormitory houses, nursery homes, 200 40 
III Accommodation facility 
 Hotels with wedding halls 200 40 
  without wedding halls 400 40 
 Motels 200 30 
 Hostels 200 40 
IV Medical facility 
 Hospital with kitchens and/or laundry services 125 40 
   less than 300 beds 125 40 
   more than 300 beds 113 36 
  without kitchens and/or laundry services 
   less than 300 beds 200 30 
   more than 300 beds 182 27 
 Small hospitals 130 40 
V Shops, stores 
 Stores, supermarkets 200 30 
 Departmental stores 200 30 
 Restaurants 
  normal pollutant loads 180 40 
  high pollutant loads 90 40 
  low pollutant loads 200 40 
 Coffee/tea houses 200 30 
VI Amusement facility 
 Disco houses 200 30 
 Bowling houses 200 30 
 Amusement parks 150 40 
 Camp sites 125 40 
 Golf courses 250 26 
VII Parking facility 
 Expressway rest areas 135 40 
 Parking facility 200 40 
 Gas station 200 40 
VIII Schools 
 Preschools, elementary schools, junior high schools 200 36 
 High schools, universities, colleges 200 36 
 Libraries 200 30 
IV Offices 
 Offices with kitchen equipment 200 40 
 without kitchen equipment 270 40 
Workplaces 
 Factories, institutes, laboratories 
  with kitchen equipment 133 30 
  without kitchen equipment 200 40 
XI Others 
 Markets 200 40 
 Public bathhouses 200 10 
 Public toilet facility 200 40 
 Stations, bus terminals 200 40 

In Japan, the johkasou capacity is usually expressed in terms of PE, and the treatment processes of johkasou, including their unit processes, are stipulated in accordance with the number of PE by the Structural Standard for Johkasou. For example, the biofilm processes are very popular in small to medium scale johkasou for 200 PE or less, while activated sludge processes are popular in medium to large scale johkasou for 201 PE or more.

Furthermore, as the treatment processes are different depending on the johkasou capacity, the content and frequency of johkasou inspection will also be different depending on the number of PE. For example, the frequency of regular inspection has, by regulation, to be conducted three times per year for johkasou with biofilm process for 20 PE or less, while four inspections per year are required for a johkasou for 21–50 PE.

The estimation of johkasou capacity in terms of PE is essential not only for planning and construction/installation, but also for operation and maintenance. A sound method for estimating the johkasou capacity as well as its operational procedures is necessary for promoting decentralized domestic wastewater treatment.

Building uses

There are 11 categories of building uses defined in the standard, as shown in Table 5, and each category contains one or more subcategories.

In the standard, a series of formulas is provided for determining the number of PE of buildings with different uses. Each formula corresponds directly to one building use that is defined in the standard.

For buildings with uses not listed in Table 5, the number of PE could be determined using the formula for buildings with similar uses.

For buildings with multipurpose uses, the number of PE must be determined by summing up the number of PE obtained with the formula for each building use.

For a johkasou serving two or more buildings, the number of PE must be determined by summing up the number of PE obtained for each building.

Unit loadings

The unit loadings for johkasou of different building uses are shown in Table 5. The wastewater amount and BOD loads shown in the table are recommended to be applied for the determination of a johkasou capacity. If the unit loading in the table is considered unreasonable, the unit loading for similar building use could be adopted.

There are cases in which there is no recommended unit loading. In such cases, the unit loading for similar building use can be adopted.

Besides BOD load, nitrogen and phosphorus unit loadings are recommended for living accommodations, which is 10 g for total nitrogen and 1.0 g for total phosphorus per capita per day.

Examples of estimating PE for different building uses

Living accommodations

The capacity of johkasou for residential buildings is basically determined by the total floor areas, as shown in Table 6.

Table 6

Determination of PE for living accommodation

Cat.Building usePE
FormulaRemarks
II Living accommodation Individual house n = 5 A < 130 n: PE
A: total floor area (m2)
P: occupancy load limit 
n = 7 A ≧ 130 
Residential complexes n = 0.05A 
Lodging houses and dormitory n = 0.07A 
School dormitory, nursery homes n = P 
Cat.Building usePE
FormulaRemarks
II Living accommodation Individual house n = 5 A < 130 n: PE
A: total floor area (m2)
P: occupancy load limit 
n = 7 A ≧ 130 
Residential complexes n = 0.05A 
Lodging houses and dormitory n = 0.07A 
School dormitory, nursery homes n = P 

In the case of individual houses, if the floor area is less than 130 m2, a 5PE johkasou is needed; if not, a 7PE johkasou will be required. For such reasons, the smallest johkasou is for 5PE, which has capacity of treating wastewater of 1.0 m3/day and 200 g-BOD/day. For a double house or a house with two kitchens, by regulation, a 10PE johkasou must be installed.

Shops and stores

The capacity of johkasou for shops and stores is determined by the total floor areas of the building, as shown in Table 7.

Table 7

Determination of PE for shops and stores

Cat.Building usePE
FormulaRemarks
Shops, stores Stores, supermarkets n = 0.075A n: PE
A: total floor area (m2
Department stores n = 0.15A 
Restaurants  
normal pollutant loads n = 0.72A 
high pollutant loads n = 2.94A 
low pollutant loads n = 0.55A 
Coffee/tea houses n = 0.80A 
Cat.Building usePE
FormulaRemarks
Shops, stores Stores, supermarkets n = 0.075A n: PE
A: total floor area (m2
Department stores n = 0.15A 
Restaurants  
normal pollutant loads n = 0.72A 
high pollutant loads n = 2.94A 
low pollutant loads n = 0.55A 
Coffee/tea houses n = 0.80A 

As wastewater discharged from shops and stores may contain oil and grease in high concentrations, a grease interceptor is required to be installed in front of a johkasou. The formulas in category V are designed for shops and stores with normal business hours, basically 8 to 10 hours per day. For the cases of those with long business hours, such as Japanese convenience stores which are open for 24 hours, the capacity of johkasou should be enhanced. For example, if a 10PE johkasou is required by the formula, it is recommended to install a 14PE johkasou for a convenience store.

Schools, offices and others

The capacity of johkasou for various schools is determined by the occupancy load limit of a school, as shown in Table 8. For high schools and universities with evening class, the occupancy load limit of evening class counts for one fourth of it when calculating the number of PE. If school canteens are available, the number of PE for school canteens should be calculated as restaurants of category V and added to the number of PE obtained by the formulas of category VIII.

Table 8

Determination of PE for schools, offices and others

Cat.Building usePE
FormulaRemarks
VIII Schools Preschools, elementary schools, junior high schools n = 0.20P n: PE
P: occupancy load limit
A: total floor area (m2)
C: number of toilet bowls 
High schools, colleges, universities n = 0.25P 
Libraries n = 0.08A 
IX Offices Offices  
with kitchen equipment n = 0.075A 
without kitchen equipment n = 0.06A 
XI Others Public toilet facility n = 16C 
Cat.Building usePE
FormulaRemarks
VIII Schools Preschools, elementary schools, junior high schools n = 0.20P n: PE
P: occupancy load limit
A: total floor area (m2)
C: number of toilet bowls 
High schools, colleges, universities n = 0.25P 
Libraries n = 0.08A 
IX Offices Offices  
with kitchen equipment n = 0.075A 
without kitchen equipment n = 0.06A 
XI Others Public toilet facility n = 16C 

An office building with kitchen equipment means that company cafeterias and/or restaurants can offer food service during business hours. The capacity of johkasou for such buildings needs to be 25% higher than those without kitchen equipment.

The quantity and quality of raw domestic wastewater were reviewed, and methods for the estimation of johkasou capacity for buildings were explained. The following conclusions were drawn:

  • The quantity of domestic wastewater was found to vary from 244 L to 265 L per capita per day according to the results of researches.

  • The pollutant loads of domestic wastewater were found to be BOD 45 g, CODMn 23 g, SS 37 g, TN 9.3 g and T-P 1.1 g per capita per day on average. It shows that the BOD load of wastewater from kitchen is higher than that of black water.

  • The pollutant loads of FWD wastewater were found to be 3.7 L for water quantity, 16–24 g for BOD, 5–19.7 g for CODMn, 7–16.1 g for SS, 0.5–2.1 g for TN and 0.1–0.3 g for TP per capita per day.

  • The unit loadings for johkasou design in the case of living accommodations are 200 L of wastewater BOD 40 g, TN 10 g and TP 1.0 g per capita per day.

  • The unit loadings (water quantity and BOD load) for the johkasou of buildings for different uses are provided informatively.

  • The johkasou capacity in terms of PE can be estimated by a series of formulas provided by a standard. The method of estimating the number of PE is very important for the implementation of on-site wastewater treatment by packaged plants.

  • Examples of estimating the number of PE for different building uses were conducted. It implies that there are special cases that should be considered when determining the number of PE by the formulas.

Fujimura
Y.
2006
Pollutant load factor of domestic wastewater and discharged loads from virous on-site wastewater treatment facilities
.
J. Water Waste
48
(
5
),
432
438
.
(in Japanese)
.
Henze
M.
,
Ledin
A.
2001
Types, characteristics and quantities of classic, combined domestic wastewater
. In:
Decentralised Sanitation and Reuse: Concepts, Systems and Implementation
(
Lens
P.
,
Zeeman
G.
&
Lettinga
G.
eds).
IWA Publishing
,
London
,
UK
, pp.
57
72
.
Horio
A.
2001
A survey on quantity and quality of raw domestic wastewater (unpublished).
Imura
M.
1994
Study on Advanced Treatment for Small-Scale Domestic Wastewater Treatment System
.
PhD thesis
,
Engineering Faculty, Tohoku University
,
Sendai
,
Japan
, pp.
41
50
.
Inamori
Y.
,
Matsushige
K.
&
Sudo
R.
1998
Removal of nitrogen and phosphorus with a small-scale johkasou combined an anaerobic reactor
.
J. Water Waste
30
(
4
),
358
364
.
(in Japanese)
.
Inamori
Y.
,
Xu
K.
,
Ebie
Y.
,
Iramori
R.
&
Matsumura
M.
2006
Prospect of proper spread conutermeasures on disposer in sustainable recirculation society under administrative control
.
J. Water Waste
48
(
7
),
586
596
.
(in Japanese)
.
Ishihara
K.
,
Ogawa
H.
,
Naka
T.
&
Kitao
T.
2006
Estimation of domestic wastewater amount based on the tap water consumption
.
J. Water Waste
43
(
3
),
195
201
.
(in Japanese)
.
Kawamura
K.
1995
Domestic Wastewater Treatment Engineering for Johkasou Technicians
.
Japan Education Center of Environmental Sanitation
,
Tokyo
,
Japan
, pp.
1
17
.
(in Japanese).
Kawamura
K.
2013
Johkasou Engineering
.
Japan Education Center of Environmental Sanitation
,
Tokyo
,
Japan
, pp.
1
13
.
(in Japanese)
.
Ministry of the Environment (MOE)
2006
A Survey on Actual Condition of Domestic Wastewater Treatment
.
Report Ministry of the Environment
,
Tokyo
,
Japan
, pp.
1
20
.
(in Japanese).
Ogawa
T.
&
Tadokoro
M.
2001
Diagnosis of Johkasou Treatment Performance and the Counter-Measures
.
Japan Education Center of Environmental Sanitation
,
Tokyo
,
Japan
, pp.
25
29
.
(in Japanese).
Tokyo Metropolitan Government Bureau of Waterworks
1997
Survey on actual conditions of household water use (in Japanese)
.
Tokyo Metropolitan Government Bureau of Waterworks
2002
Survey on actual conditions of household water use (in Japanese)
.