Abstract
Common methods for treating surface waters involve chemical flocculation, for which a significant factor contributing to the total cost and climate impact is the consumption of chemicals, chiefly coagulants and pH-adjusting chemicals. The amount of chemicals required for treating surface waters and achieving suitable flocculation pH depends greatly on the alkalinity of the source water. This study investigates the viability of mixing two surface waters with different chemical properties with the aim of reducing the amount of chemicals used during chemical flocculation. Bench-scale experiments were carried out, and the results were compared with full-scale operations at a surface water treatment plant (WTP). The WTP uses ferric chloride as a coagulant, which effectively removes natural organic matter, but consumes large amounts of hydroxide to manage pH before and after flocculation. As an alternative process, this study tested the use of aluminum sulfate, polyaluminum chloride and ferric chloride at varying dosages in combination with different source water mixtures to achieve suitable flocculation pH. The results showed that pH-adjusting chemicals could be omitted by adding a small amount of high alkalinity surface water to the primary source water, thereby reducing costs and climate impact substantially.
HIGHLIGHTS
Mixing raw waters with different properties could substantially reduce costs and climate impact.
Aluminum sulfate offered potential cost savings of up to 40% and a reduction in climate impact by up to 36% compared to conventional ferric chloride precipitation.
Polyaluminum chloride with high basicity offered a broader coagulant dosage range, reducing the need for pH adjustment and potentially allowing for higher dosages.
INTRODUCTION
Common methods for treating surface waters that are rich in organic compounds are artificial groundwater recharge (Dillon et al. 2009; Sprenger et al. 2017; Stefan & Ansems 2018) and coagulation and flocculation (Crittenden et al. 2017), where coagulants based on Fe3+ and Al3+ are often used to remove natural organic matter (NOM) due to their efficiency and low cost (Bratby 2016). The optimal pH range varies for these coagulants and depends on the specific impurities that are being targeted for removal (Naceradska et al. 2019). Fe3+ coagulants tend to have a lower optimal pH and be more effective at removing NOM than Al3+ coagulants, while Al3+ coagulants have a wider optimum pH range at higher pH values (Gillberg et al. 2003; Jarvis 2004). However, Al3+ coagulants have been shown to have different pH optimums with regard to coagulant residuals and NOM removal (Pivokonský et al. 2022). This could lead to concerns of residual aluminum when using Al3+ coagulants. However, this is generally not an issue around pH 6–6.5, depending on temperature, organic matter content, coagulant, basicity and coagulant dosage (Gillberg et al. 2003; Gao et al. 2006; Matilainen et al. 2010; Kimura et al. 2013; Pivokonský et al. 2022).
The Southern Sweden Water Supply (Sydvatten AB) is a municipality-owned water utility that produces potable water for over 950,000 inhabitants in southern Sweden. This is mainly done through two waterworks (WW), Ringsjö WW and Vomb WW. Over 90% of Sydvatten AB's climate impact comes from the production and transport of chemicals used for water treatment, which corresponds to about 70 kg CO2 equivalent per cubic meter of water (see Sydvatten AB (2021a) for detailed descriptions of how climate impact is calculated). The largest contributor (about 50%) to the total chemical consumption is the coagulant, FeCl3, followed by Ca(OH)2, CO2 and NaOH. NaOH is used for adjusting pH prior to coagulation, while the combination of Ca(OH)2 and CO2 is used to adjust the pH and increase alkalinity after flocculation (Sydvatten AB 2021b).
The chemicals used for water treatment also come at a significant price (Lidén & Persson 2016) and energy price increases, and global supply chain disruptions have caused prices to increase even more in recent years (LaBelle & Santacreu 2022). NaOH contributes to about 50% of the total chemical costs at Ringsjö WW in 2021, and the cost of NaOH increased by nearly 60% in 2022. Supply chain disruptions are a growing concern for water utilities that rely on these chemicals for water production. These disruptions can arise for many different reasons and can affect deliveries of chemicals, such as NaOH (EPA 2022). Thus, the importance of minimizing the WW reliance on these chemicals cannot be understated from cost, water supply security and climate impact perspectives.
Southern Sweden is a fast-growing region, and more municipalities are joining Sydvatten AB (Länsstyrelsen i Skåne Län et al. 2016). As a result, Sydvatten AB is planning to build a new source water pipeline transporting water to Vomb WW, an artificial groundwater recharge plant. Based on previous studies (Hägg 2020), the new raw water source originating from Lake Bolmen, requires pre-treatment through chemical flocculation prior to groundwater recharge. The water from Lake Bolmen is soft and has low alkalinity. Treatment of the water requires substantial pH adjustments before and after flocculation, especially when using FeCl3 as a coagulant. In a series of jar tests, this study investigates the possibility of reducing the need for pH-adjusting chemicals by mixing water from Lake Bolmen with water from Lake Vomb, hard water with high alkalinity. The investigation includes three different coagulants (aluminum sulfate (ALG), polyaluminum chloride (PAX XL60) and ferric chloride (PIX 311)), and the results were compared to full-scale operations at Ringsjö WW based on cost and climate impact.
MATERIALS AND METHODS
Source water and water works
Sampling point . | Color (mg Pt/L) . | CODMn (mg/L) . | TOC (mg/L) . | pH . | Alkalinity (mg HCO3-/L) . | Hardness (°dH) . |
---|---|---|---|---|---|---|
Lake Bolmen | 84 | N/A | 10.1 | 6.9 | 7.32 | N/A |
Intake Ringsjö WW after the tunnel | 66.3 | 11 | 9.5 | 6.9 | 12.6 | 1.2 |
Treated water Ringsjö WW | <5 | 1.4 | N/A | 8.1 | 45 | 3.5 |
Lake Vomb | 23 | 6.0 | 7.6 | 8.3 | 161 | 10 |
Treated water Vomb WW | <5 | 1.7 | N/A | 8.2 | 140 | 6.5 |
Sampling point . | Color (mg Pt/L) . | CODMn (mg/L) . | TOC (mg/L) . | pH . | Alkalinity (mg HCO3-/L) . | Hardness (°dH) . |
---|---|---|---|---|---|---|
Lake Bolmen | 84 | N/A | 10.1 | 6.9 | 7.32 | N/A |
Intake Ringsjö WW after the tunnel | 66.3 | 11 | 9.5 | 6.9 | 12.6 | 1.2 |
Treated water Ringsjö WW | <5 | 1.4 | N/A | 8.1 | 45 | 3.5 |
Lake Vomb | 23 | 6.0 | 7.6 | 8.3 | 161 | 10 |
Treated water Vomb WW | <5 | 1.7 | N/A | 8.2 | 140 | 6.5 |
Vomb WW treats water from Lake Vomb using disc filters (40 μm) before pumping the water to infiltration basins excavated in the recharge field consisting of glacifluvial deposits. Treatment after well extraction includes aeration, softening and rapid sand filtration (Figure A2). Lake Vomb is hypertrophic due to runoff from the agricultural lands in the catchment area, which causes seasonal algae blooms (Skåne County 2012; Li 2020). The organic composition of source water from Lake Vomb has slightly higher dissolved organic matter originating from microbial sources as opposed to terrestrial sources (Hägg et al. 2021b). As a result, Lake Vomb has lower UV absorbance254nm (about 20 m−1) and SUVA (around 2 L m−1 mg−1) compared to Lake Bolmen.
The lake water extraction at Vomb WW is increasing due to the increased water demand. For this reason, a new source water pipeline, transporting water from Lake Bolmen, will be connected to Vomb WW within 10 years (Figure 1). The high NOM content and NOM composition in source water from Lake Bolmen makes the water suitable for coagulation and flocculation but not for biofiltration (Hägg et al. 2021a); consequently, a pre-treatment facility will also be built at Vomb WW. Once the source water pipeline is built, Vomb WW will pre-treat a mixture of water from Lake Bolmen and Lake Vomb through coagulation and flocculation prior to infiltration. It is expected that a mixture of the two waters will eliminate the need for the softening reactors after infiltration, due to the soft water from Lake Bolmen (Table 1). The combination of chemical flocculation and artificial recharge reduces the need for extensive NOM removal through the flocculation process, enabling the use of a wider range of coagulants that were not previously feasible for water treatment.
Chemical consumption and climate impact
Sydvatten AB's total annual climate impact is about 5,800 tons CO2-eq, whereby over 90% comes from the production of chemicals used in the treatment process (Sydvatten AB 2021a). At Ringsjö WW, NaOH and Ca(OH)2 are used for pH adjustment before and after flocculation, while at Vomb WW, NaOH is used in the softening reactors. A significant part of the cost and climate impact comes from the use of these chemicals (Table 2).
WW . | Chemical . | Chemical consumption 2021 (ton) . | Cost 2021 ($/ton) . | Cost 2022 ($/ton) . | Climate impact (kg CO2-eq/ton) . | Climate impact 2021 (ton CO2-eq) . | Application . |
---|---|---|---|---|---|---|---|
Ringsjö WW | FeCl3 | 3,597 | 154 | 188 | 0.400 | 1,439 | Coagulant |
Ca(OH)2 | 1,652 | 135 | 175 | 0.917 | 1,515 | pH adjustment | |
CO2 | 901 | 95 | 99 | 0.625 | 563 | Alkalinity adjustment | |
NaOH (50%) | 904 | 207 | 330 | 0.446 | 403 | pH adjustment | |
Vomb WW | NaOH (50%) | 2,921 | 207 | 330 | 0.446 | 1,303 | Softening reactor |
Jar tests | ALG | N/A | N/A | 205 | 0.320 | N/A | Coagulant |
PAX XL60a | N/A | N/A | 227 | 0.447 | N/A | Coagulant |
WW . | Chemical . | Chemical consumption 2021 (ton) . | Cost 2021 ($/ton) . | Cost 2022 ($/ton) . | Climate impact (kg CO2-eq/ton) . | Climate impact 2021 (ton CO2-eq) . | Application . |
---|---|---|---|---|---|---|---|
Ringsjö WW | FeCl3 | 3,597 | 154 | 188 | 0.400 | 1,439 | Coagulant |
Ca(OH)2 | 1,652 | 135 | 175 | 0.917 | 1,515 | pH adjustment | |
CO2 | 901 | 95 | 99 | 0.625 | 563 | Alkalinity adjustment | |
NaOH (50%) | 904 | 207 | 330 | 0.446 | 403 | pH adjustment | |
Vomb WW | NaOH (50%) | 2,921 | 207 | 330 | 0.446 | 1,303 | Softening reactor |
Jar tests | ALG | N/A | N/A | 205 | 0.320 | N/A | Coagulant |
PAX XL60a | N/A | N/A | 227 | 0.447 | N/A | Coagulant |
Notes: The climate impact for each chemical depends on the supplier; therefore, national data from the Swedish Water and Wastewater Association (SWWA) is presented, rather than data specific to Ringsjö WW (SWWA 2022). Chemicals used at Ringsjö WW and Vomb WW that were not relevant for this study were not included, e.g. sodium hypochlorite.
aCost and climate impact for PAX XL60 was taken from the manufacturer Kemira.
Jar tests
Prior to the jar tests, samples of raw water with added coagulant were pH tested (using a WTW pH-197, pH meter) to ensure the correct targeted pH during flocculation. The required NaOH or HCl amount was measured and used for chemical consumption calculations. Jar tests were conducted using a program-controlled flocculator (Flocculator 2000, Kemira; Helsingborg, Sweden). The setup consisted of six 1 L glass beakers and the jar test procedure was as follows:
- 1.
Each beaker was filled with 1 L raw water.
- 2.
NaOH or HCl solutions were added to the beakers prior to flocculation.
- 3.
The flocculator program was initiated: 30 s rapid mixing (400 rpm), 20 min slow mixing (50 rpm) and 30 min sedimentation (0 rpm).
- 4.
The coagulant was added when 5 s remained of the rapid mixing and the pH was measured during slow mixing.
- 5.
Samples were taken with a 30 mL syringe 5 cm below the surface, when sedimentation was finished.
Coagulants and additives
ALG (Al2(SO4)3) in solid state, PAX XL60 (PACl) in liquid state and PIX 311 solution (FeCl3) were used as coagulants in this study. The ALG was a 9.1% by weight Al3+ dry product and was prepared by dissolving granules in distilled water to a 200 g/L solution. The PAX XL60 used was a 7.5% by weight Al3+ solution with a basicity of 40 ± 5%. PIX 311 was a 40% by weight FeCl3 and a 13.8% by weight Fe3+ solution. All three products were approved for drinking water treatment and produced by Kemira (Helsinki, Finland). A 0.36% NaOH and a 3.7% HCl solution were used to control the resulting pH during the jar tests.
Methodology
The future pretreatment plant at Vomb WW will treat a mixture of the two source waters, with approximately 10–30% water from Lake Vomb, to achieve the desired chemical properties (i.e., alkalinity) and ensure the distribution of non-corrosive (iron and copper) drinking water. In this study, the three coagulants (ALG, PAX XL60 and PIX 311) were used with different dosages and source water mixtures. The source water mixtures were 10, 20 and 30% Vomb water, and the results were compared to full-scale flocculation at Ringsjö WW, where flocculation pH is controlled by NaOH additions. A cost and climate impact estimation was conducted based on the chemical usage for each treatment option. A series of titration trials was also conducted with the different water mixtures to investigate the required amount of NaOH to reach a pH of 7 after flocculation. A pH of approximately 7 was assumed to be suitable for the infiltration ponds downstream of the chemical precipitation. The required amount of Ca(OH)2, including 7% loss due to CaCO3 impurities in the slaked lime product, was calculated based on the consumption of hydroxide from NaOH adjustment.
The selected residual UV254nm absorbance and VIS436nm absorbance targets were 10 and 0.7 m−1, respectively, based on previously conducted jar tests using FeCl3 and water from Lake Bolmen (Figure A3). High coagulant dosages and the resulting low pH could cause an increase in residual aluminum (Crittenden et al. 2017). Therefore, a minimum targeted flocculation pH of 6 was selected to mitigate the potential risk of residual aluminum (Yang et al. 2010). A common flocculation pH range for Fe-based coagulants is 4.5–6 (Matilainen et al. 2010), and, based on experience from full-scale operations, a minimum flocculation pH was set to 4.5 to minimize the risks of residual iron. Once these requirements were fulfilled, the resulting climate impact (measured as kg CO2-eq/m3 water) and cost (USD) of each option were calculated based on the chemical consumption. The costs were taken from the Swedish market, and the exchange rate used was 1 dollar (USD) to 11 Swedish kronor (SEK).
Waters sample analysis
Water samples before and after the jar tests were tested for UV–VIS absorbance using a spectrophotometer (DR 5000, Hach Lange, Loveland, CO, USA). The absorption was measured at λ = 254 and 436 nm using a 5-cm cuvette. The raw water temperature, pH and the UV–VIS absorbance varied depending on the raw water mixture used during the jar tests (Table 3).
Vomb:Bolmen (%) . | UV abs (λ = 254 nm, m−1) . | VIS abs (λ = 436 nm, m−1) . | pH . | Temperature range (°C) . |
---|---|---|---|---|
0:100 | 34.2 ± 0.2 | 2.3 ± 0.1 | 6.8 | 13–16 |
10:90 | 34.5 ± 0.2 | 2.3 ± 0.1 | 6.9 | 18–20 |
20:80 | 33.1 ± 0.6 | 2.3 ± 0.2 | 7.2 | 19–20 |
30:70 | 32.2 ± 0.9 | 2.4 ± 0.1 | 7.4 | 19–21 |
Vomb:Bolmen (%) . | UV abs (λ = 254 nm, m−1) . | VIS abs (λ = 436 nm, m−1) . | pH . | Temperature range (°C) . |
---|---|---|---|---|
0:100 | 34.2 ± 0.2 | 2.3 ± 0.1 | 6.8 | 13–16 |
10:90 | 34.5 ± 0.2 | 2.3 ± 0.1 | 6.9 | 18–20 |
20:80 | 33.1 ± 0.6 | 2.3 ± 0.2 | 7.2 | 19–20 |
30:70 | 32.2 ± 0.9 | 2.4 ± 0.1 | 7.4 | 19–21 |
Note: The average UV–VIS absorbance, pH and temperature ranges of the source water mixtures area shown.
RESULTS AND DISCUSSION
Coagulant dosage effects on pH and residual NOM
PAX XL60 did not lower the pH to the same extent as ALG (Figure 3(b)), which is consistent with the findings from previous studies (Matilainen et al. 2010; Nowacka et al. 2014) and the information provided by the manufacturer (Kemira). Consequently, slightly higher dosages of PAX XL60 were required to reach the targeted residual UV254nm absorbance and minimum pH. For this reason, additional trials were conducted with water only from Lake Bolmen. However, it was possible to achieve the targets only with a coagulant dosage of 148 mmol/m3, and the residual UV254nm absorbance increased significantly when the coagulant dosage was above 200 mmol Al3+/m3. A similar UV absorbance increase occurred with the 10:90 water mixture at around the same pH (approximately 5.5) but at a higher coagulant dosage (above 300 mmol Al3+/m3). This could be the result of restabilization caused by charge reversal or a bridging mechanism due to excessive surface coverage of Al(OH)4− (Bratby 2016; Kong et al. 2021). With water mixtures of 10:90, 20:80 and 30:70, the targets were achieved at coagulant dosages of 185–259, 222–370 and 222–370 mmol/m3, respectively. Therefore, a viable coagulant dosage range for PAX XL60 was 148–370 mmol Al3+/m3 (4–10 mg Al3+/L) with a pH of 6–6.8.
Chemical consumption, costs and climate impact*
The chemical consumption, costs and climate impact were calculated to optimize for operational reliability and for low chemical consumption separately (Table 4). The configuration with the lowest cost and chemical consumption for each coagulant is presented in parentheses. For these configurations, a coagulant dosage at the lower end of the flocculation window was chosen: 148 mmol/L for ALG, 185 mmol/L for PAX and 167 mmol/L for PIX 311. The results show that ALG had the lowest cost and climate impact compared to other options, including the reference (full-scale operations at Ringsjö WW). PAX XL60 and PIX-311 had similar costs, but PIX-311 had a significantly higher climate impact due to the increase of Ca(OH)2 post-flocculation.
Chemical . | ALG . | PAX XL60 . | PIX-311 . | Ringsjö WW . |
---|---|---|---|---|
Coagulant (mmol M3+/m3+) | 185 (148) | 222 (185) | 241 (167) | 194 |
Coagulant (mg M3+/L) | 5 (4) | 6 (5) | 13.4 (9.3) | 10.8a |
Flocculation pH | 6 (6.2) | 6.2 (6.3) | 5.3 (5.3) | 5.0 |
NaOH (50%) (tons/year) | 0 | 0 | 0 | 904 |
Ca(OH)2 (100%) (tons/year) | 740 (570) | 440 (350) | 1,210 (850) | 550 |
Vomb:Bolmen (%) | 20:80 (20:80) | 10:90 (10:90) | 20:80 (10:90) | 0:100 |
Residual UV abs (254 nm/m) | 7.8 (9.8) | 7.9 (9.4) | 6.1 (8.2) | 5b |
Total cost 2022 (USD) | 0.65M (0.52M) | 0.92M (0.77M) | 1.06M (0.74M) | 1.07M |
Climate impact (ton CO2-eq) | 1,500 (1,180) | 2,070 (1,710) | 2,920 (2,040) | 2,350 |
Chemical . | ALG . | PAX XL60 . | PIX-311 . | Ringsjö WW . |
---|---|---|---|---|
Coagulant (mmol M3+/m3+) | 185 (148) | 222 (185) | 241 (167) | 194 |
Coagulant (mg M3+/L) | 5 (4) | 6 (5) | 13.4 (9.3) | 10.8a |
Flocculation pH | 6 (6.2) | 6.2 (6.3) | 5.3 (5.3) | 5.0 |
NaOH (50%) (tons/year) | 0 | 0 | 0 | 904 |
Ca(OH)2 (100%) (tons/year) | 740 (570) | 440 (350) | 1,210 (850) | 550 |
Vomb:Bolmen (%) | 20:80 (20:80) | 10:90 (10:90) | 20:80 (10:90) | 0:100 |
Residual UV abs (254 nm/m) | 7.8 (9.8) | 7.9 (9.4) | 6.1 (8.2) | 5b |
Total cost 2022 (USD) | 0.65M (0.52M) | 0.92M (0.77M) | 1.06M (0.74M) | 1.07M |
Climate impact (ton CO2-eq) | 1,500 (1,180) | 2,070 (1,710) | 2,920 (2,040) | 2,350 |
Notes: The annual chemical consumption was calculated based on Ringsjö WW annual water production 2021 (46.6 Mm3) (Sydvatten 2021b). The cost and climate impact were obtained from the manufacturer (Kemira) and SWWA (2022). The results shown are optimized for operational reliability, while the results optimized for cost and climate impact are shown in parentheses.
aAverage FeCl3 dosage from full-scale treatment.
b After rapid sand filtration.
To optimize for operational reliability, configurations were chosen for each coagulant to allow for a wider flocculation window, while keeping chemical consumption at a reasonable level. The coagulant dosages chosen for ALG, PAX XL60 and PIX 311 were 185, 222 and 241 mmol/L, respectively. In this configuration, both ALG and PAX XL60 had lower cost and climate impact than PIX 311 and the reference. PIX-311 had similar cost and higher climate impact than the reference, suggesting that source water mixing might not be viable when using this coagulant. ALG was cheaper than PAX XL60, despite the fact that ALG required more calcium hydroxide to increase pH up to 7, due to the increased buffer capacity of the water mixture. Moreover, compared to PAX XL60, ALG had a lower cost per ton and a higher aluminum content, 9.1% versus 7.5%. A PACl product with higher aluminum content would likely reduce the coagulant dosage and be more cost-effective.
Overall, compared to conventional precipitation with PIX 311 and pH adjustments prior to coagulation, choosing an aluminum-based coagulant in combination with harnessing source water mixtures could potentially reduce costs by as much as approximately 40% and lessen the climate impact by up to approximately 36%. It should be noted, however, that PIX 311 removed NOM more effectively than the aluminum-based coagulants.
Operational reliability and water quality
It was possible to achieve the targeted UV254nm absorbance and VIS436nm absorbance for all coagulants. The VIS436nm absorbance target was more readily reached and therefore not included, see Figure A4. PIX 311 was the most effective at removing NOM and was cost-efficient in combination with low-alkalinity source waters (10% Vomb water). However, the flocculation window was very narrow, which could increase operational risks due to the natural variation of source water qualities and the lack of precision in pH control through source water mixing. Configurations with PIX 311 and 20% Vomb water mixtures did not have this issue but instead came at very high costs and climate impact. PAX XL 60 had a broader coagulant dosage range, and there were indications that higher dosages beyond 370 mmol Al3+/m3 (10 mg Al3+/L) were viable with the tested source water mixtures. PAX XL60 lowered pH less than ALG and PIX 311, which enabled flocculation at higher pH and thereby required less pH buffering through NaOH additions or increased amounts of Vomb water. The reason for this is that pre-hydrolyzed PACl with high basicity, such as PAX XL60, lowers alkalinity to a lesser degree than other coagulants (Crittenden et al. 2012). However, the residual UV254nm absorbance might increase when the coagulant dosage is high and if pH gets below roughly 5.5. Increased residual UV254nm absorbance also occurred when using PIX 311 at a pH around 4.5. This could be amended by increasing the alkalinity of the raw water mixture or by NaOH additions to increase pH. In full-scale operations, the flocculation pH would be managed toward higher pH, and this would not be a concern. Lower dosages of ALG were needed to reach the targeted UV absorbance compared to PAX XL60, which lowered the cost and climate impact of this option. ALG lowered pH more and narrowed the flocculation window but not to the same extent as PIX 311. The new treatment facility at Vomb WW will combine chemical flocculation with artificial groundwater recharge, which will reduce the NOM removal requirements after flocculation. Therefore, an aluminum-based coagulant could be used, even though it is not as effective as PIX 311 at removing NOM.
It is preferable that drinking water production be based on a process that has minimal dependence on chemicals from foreign countries. In addition, various solutions should be prepared in the process design to handle unexpected shortages. In this article, it has been shown that aluminum-based coagulants, both in solid and liquid state, with sulfate or chloride as counter ions, and whether polymerized or not, can be used to reach the required quality of the water. Furthermore, by adjusting the mixture of raw water from Bolmen and Vomb, the need for pH-adjusting chemicals can be minimized. In cases of deteriorating source water quality (e.g. due to increased NOM content or turbidity), whether temporary or long-term, a higher coagulant dosage would be used and the need for pH-adjusting chemicals could be amended by using a suitable mixture of the two raw waters. The flexibility in this process design gives the required tools to handle future variations in the global chemical market and lake water qualities in a very effective way and allows for substantial reduction of the carbon footprint of Sydvatten.
CONCLUSIONS
This study showed that it was possible to substantially reduce the costs and climate impact associated with chemical consumption for water treatment by mixing raw waters with different chemical properties. Increasing raw water alkalinity removed the need for pH-adjusting chemicals prior to flocculation, but it also increased the need for calcium hydroxide post-flocculation due to the increased buffer capacity. Adding 10–30% lake water with high alkalinity could reduce costs by approximately 40% and climate impact by around 36%, compared to conventional precipitation with PIX 311. However, this approach does result in lower NOM removal efficiencies. The iron-based coagulant was more effective at removing NOM than aluminum-based ones, but they had a higher cost and climate impact.