Flame retardants are chemicals that are added to plastic materials in order to prevent them from catching fire and to slow down the burning process. Due to the widespread occurrence of flame retardants in the environment, it can be expected that especially the more hydrophilic compounds already contaminate raw water resources of water utilities. In this paper results of laboratory-scale experiments on the behaviour of ten brominated and chlorinated flame retardants during different steps of drinking water treatment will be presented. The target compounds were selected based on their production volumes and physical-chemical properties. The final list includes 1- and 2-bromostyrene, 2,4- and 2,6-dibromophenol, tetrabromophthalic acid, tetrachlorophthalic anhydride, chlorendic acid, tris(1,3-dichloro-2-propyl) phosphate, tris(2-chloroethyl) phosphate (TCEP), and tris(1-chloro-2-propyl) phosphate (TCPP). The results obtained from the laboratory-scale experiments clearly indicate that from the selected flame retardants only 1- and 2-bromostyrene are well biodegradable under aerobic conditions whereas the other flame retardants under investigation turned out to be persistent. Flocculation with either iron or aluminium salts is not an efficient option for removal of the selected flame retardants. For 1- and 2-bromostyrene removal rates of ca. 50% can be achieved whereas for the other compounds removal rates are in the range of 10 to 30% even when dosing 50 mg/L of flocculation agent. Oxidation with either ozone or ozone/hydrogen peroxide proved also to be rather inefficient for removal of the flame retardants under investigation, even at elevated doses of oxidant of 10 mg/L. However, results showed that the selected flame retardants adsorb well onto activated carbon and thus GAC adsorption seems to be a promising option for their removal.
Skip Nav Destination
Article navigation
Research Article|
September 01 2010
Behaviour of brominated and chlorinated flame retardants during drinking water treatment
F. Sacher;
1DVGW-Technologiezentrum Wasser (TZW), Karlsruher Strasse 84, 76139 Karlsruhe, Germany E-mail: [email protected]; [email protected]; [email protected]; [email protected]
E-mail: [email protected]
Search for other works by this author on:
B. Körner;
B. Körner
1DVGW-Technologiezentrum Wasser (TZW), Karlsruher Strasse 84, 76139 Karlsruhe, Germany E-mail: [email protected]; [email protected]; [email protected]; [email protected]
Search for other works by this author on:
A. Thoma;
A. Thoma
1DVGW-Technologiezentrum Wasser (TZW), Karlsruher Strasse 84, 76139 Karlsruhe, Germany E-mail: [email protected]; [email protected]; [email protected]; [email protected]
Search for other works by this author on:
H.-J. Brauch;
H.-J. Brauch
1DVGW-Technologiezentrum Wasser (TZW), Karlsruher Strasse 84, 76139 Karlsruhe, Germany E-mail: [email protected]; [email protected]; [email protected]; [email protected]
Search for other works by this author on:
D. Khiari
D. Khiari
2Water Research Foundation, 6666 West Quincy Avenue, Denver, CO 80236-3098, US E-mail: [email protected]
Search for other works by this author on:
Water Supply (2010) 10 (4): 610–617.
Citation
F. Sacher, B. Körner, A. Thoma, H.-J. Brauch, D. Khiari; Behaviour of brominated and chlorinated flame retardants during drinking water treatment. Water Supply 1 September 2010; 10 (4): 610–617. doi: https://doi.org/10.2166/ws.2010.183
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00