A 5-year survey (2003 to 2007) was carried out on various drinking water sources in Israel for detection of Legionella spp. The most frequently isolated species was L. pneumophila serogroup 3 (prevalence 60.44±5.6) followed by L. pneumophila serogroup 1 (26.98±5.2) and other serogroups and unidentified species (12.6±9.8). L. pneumophila serogroup 1 is the worldwide prevalent serogroup in water sources while serogroup 3 was only occasionally reported. Previous reports on L. pneumophila serogroup 1 as the main causative of respiratory disease in Israel revealed a drop from 52 to 15% in incidence during a 5-year survey, with a rise in the incidence of seropositivity to “other Legionellae”, mainly sg. 3. As antigenuria is the main clinical tool to detect Legionellosis among infected patients, the shift from serogroup 1 to serogroup 3 in water sources will go undetected for obvious reasons. The process of serogroups prevalence shift in water sources is an interesting issue that has to be investigated further in order to advance our understanding of Legionella epidemiology.
Skip Nav Destination
Close
Close
Article navigation
Research Article|
December 01 2010
Legionella pneumophila serogroup 3 prevalence in drinking water survey in Israel (2003–2007)
Rachel Yarom;
1Department of Microbiology, Public Health Laboratory, Ministry of Health, Haifa 35055, Israel
Search for other works by this author on:
Rivka Sheinman;
Rivka Sheinman
1Department of Microbiology, Public Health Laboratory, Ministry of Health, Haifa 35055, Israel
Search for other works by this author on:
Robert Armon
Robert Armon
2Faculty of Civil & Environmental Engineering, Division of Environmental, Water & Agricultural Eng., Technion-Israel Institute of Technology, Haifa 32000, Israel
Search for other works by this author on:
Water Supply (2010) 10 (5): 746–752.
Citation
Rachel Yarom, Rivka Sheinman, Robert Armon; Legionella pneumophila serogroup 3 prevalence in drinking water survey in Israel (2003–2007). Water Supply 1 December 2010; 10 (5): 746–752. doi: https://doi.org/10.2166/ws.2010.489
Download citation file:
Close
Citation
Rachel Yarom, Rivka Sheinman, Robert Armon; Legionella pneumophila serogroup 3 prevalence in drinking water survey in Israel (2003–2007). Water Supply 1 December 2010; 10 (5): 746–752. doi: https://doi.org/10.2166/ws.2010.489
Download citation file:
Close
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Impact Factor 0.900
CiteScore 1.5
13
Views
0
Citations