In water treatment, virus removal using ultrafiltration is a major step towards better water quality. In this paper, we study virus filtration efficiency using surrogate virus particles and via statistical surface-response approach. We focus on the effect of particle size (20–100 nm range) as a key factor along with the effects of transmembrane pressure (20–60 kPa range) and feed flowrate (0.3–1.0 L/F;min range) on the filtration virus removal efficiency (LRV). The particle size is shown to impart a great deal of influence on surrogate particle removal. The effect of particle-to-pore-size ratio is reported for comparison of membrane molecular weight cut off (MWCO) performance. It was shown experimentally and through the developed empirical regression model that transmembrane pressure plays a major role in controlling the filtration efficiency along with flowrate. In the studied experimental range, higher LRV values are obtained at lower transmembrane pressure (20 kPa) and at higher feed flowrate (1 L/F;min). Further the effect on LRV of the interaction between transmembrane pressure and particle size seems to be more significant than that of the interaction of flowrate with particle size.
Skip Nav Destination
Article navigation
Research Article|
March 01 2011
Influence of particle size and operating parameters on virus ultrafiltration efficiency Available to Purchase
Angayar K. Pavanasam;
1UNESCO Centre for Membrane Science and Technology, School of Chemical Sciences and Engineering, University of New South Wales, Sydney 2052, Australia E-mail: [email protected]; [email protected]
E-mail: [email protected]
Search for other works by this author on:
Ali Abbas;
Ali Abbas
2Laboratory for Multiscale Systems, School of Chemical and Biomolecular Engineering, University of Sydney, Sydney 2006, Australia E-mail: [email protected]
Search for other works by this author on:
Vicki Chen
Vicki Chen
1UNESCO Centre for Membrane Science and Technology, School of Chemical Sciences and Engineering, University of New South Wales, Sydney 2052, Australia E-mail: [email protected]; [email protected]
Search for other works by this author on:
Water Supply (2011) 11 (1): 31–38.
Citation
Angayar K. Pavanasam, Ali Abbas, Vicki Chen; Influence of particle size and operating parameters on virus ultrafiltration efficiency. Water Supply 1 March 2011; 11 (1): 31–38. doi: https://doi.org/10.2166/ws.2011.005
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00