In this paper, a time domain reflectometry (TDR)-based solution for detecting water leaks in underground pipes is described and experimentally validated. The proposed method strongly reduces the inspection time that is typically required by traditional leak detection methods. In fact, it can successfully inspect pipes that are hundreds of meters long. In this work, two different configurations of the system are described: one can be used for detecting leaks in ‘already-installed’ metal pipes; whereas the other is suitable to be employed for detecting leaks in ‘newly-installed’ pipes made of any material. The performance of both these system configurations was assessed through an extensive, on-site experimental campaign, carried out with the collaboration of one of the largest European water operators, Acquedotto Pugliese S.p.A. (AQP). Representative results, related to both configurations, of three experimental cases (ECs) are reported and commented on. Finally, some practical considerations on the applicability of the system are provided.
Skip Nav Destination
Article navigation
Research Article|
August 01 2013
An electromagnetic-based method for pinpointing leaks in buried pipes: a practical validation Available to Purchase
A. Cataldo;
A. Cataldo
1Department of Engineering for Innovation, University of Salento, via Monteroni, 73100 Lecce, Italy
Search for other works by this author on:
G. Cannazza;
G. Cannazza
1Department of Engineering for Innovation, University of Salento, via Monteroni, 73100 Lecce, Italy
Search for other works by this author on:
E. De Benedetto;
1Department of Engineering for Innovation, University of Salento, via Monteroni, 73100 Lecce, Italy
E-mail: [email protected]
Search for other works by this author on:
M. Miraglia;
M. Miraglia
2Acquedotto Pugliese S.p.A, via Cognetti 36, 70121 Bari, Italy
Search for other works by this author on:
D. Ancora;
D. Ancora
2Acquedotto Pugliese S.p.A, via Cognetti 36, 70121 Bari, Italy
Search for other works by this author on:
N. Giaquinto
N. Giaquinto
3Department of Electrical and Electronic Engineering, Politecnico di Bari, via Orabona, 70125 Bari, Italy
Search for other works by this author on:
Water Supply (2013) 13 (4): 966–976.
Article history
Received:
September 03 2012
Accepted:
January 04 2013
Citation
A. Cataldo, G. Cannazza, E. De Benedetto, M. Miraglia, D. Ancora, N. Giaquinto; An electromagnetic-based method for pinpointing leaks in buried pipes: a practical validation. Water Supply 1 August 2013; 13 (4): 966–976. doi: https://doi.org/10.2166/ws.2013.085
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00