Green roof systems have been suggested to ease the growing urban environmental problems resulting from rapid urbanization. However, the irrigation of green roofs heavily depends on using precious potable water and consequently generates negative environmental effects. Rainwater has been recommended to address this dilemma, but the design method has not been well developed. In this study, the major design factors of a rainwater harvesting system for green roof irrigation systems are examined, and a simulation-based mathematical model is established to elucidate the correlation between tank volume and system performance. The optimal system design and probability distribution of the potable water replacement rate are also discussed on the basis of a case study of a university building in Keelung, Northern Taiwan. The results show that the optimal tank volume, potable water replacement rate, and probability of exceedance are 9.41 m3, 92.72%, and 88.76% (±1SD), respectively. In addition, the economic performance is identified to be feasible. Hence, the design method has been verified to be a useful tool to ease the urban environmental issues.
Skip Nav Destination
Article navigation
Research Article|
October 30 2014
Designing a rainwater harvesting system for urban green roof irrigation Available to Purchase
Liaw Chao-Hsien;
Liaw Chao-Hsien
1Department of Harbor and River Engineering, National Taiwan Ocean University, No. 2, Beining Rd., Zhongzheng Dist., Keelung City 202, Taiwan
Search for other works by this author on:
Huang En-Hao;
Huang En-Hao
1Department of Harbor and River Engineering, National Taiwan Ocean University, No. 2, Beining Rd., Zhongzheng Dist., Keelung City 202, Taiwan
Search for other works by this author on:
Chiu Yie-Ru
2Center for General Education, Tzu Chi University, No. 701, Sec 3, Zhong-Yong Rd, Hualien 970, Taiwan
E-mail: [email protected]; [email protected]
Search for other works by this author on:
Water Supply (2015) 15 (2): 271–277.
Article history
Received:
May 21 2014
Accepted:
October 14 2014
Citation
Liaw Chao-Hsien, Huang En-Hao, Chiu Yie-Ru; Designing a rainwater harvesting system for urban green roof irrigation. Water Supply 1 April 2015; 15 (2): 271–277. doi: https://doi.org/10.2166/ws.2014.107
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00