In this work, an integrative passive sampler based on a silicone membrane filled with a suspension of γ-Fe2O3 at pH 3.5 was developed. The novel device was calibrated for the measurement of microcystin concentrations in water. Laboratory calibration studies of the passive sampling devises under controlled conditions of temperature, water turbulence, and analyte concentration were conducted in order to establish how variable environmental conditions affect the novel sampler's performance. The chemical uptake of microcystin (MC)-RR, -LR, and -YR into the passive sampler remained linear and integrative throughout the 28-day exposure. The relative standard deviations of mean concentrations obtained using silicone-based sampler ranged from 1.42 to 3.74% for microcystin-LR, -RR, and -YR. The values for reproducibility from triplicate samplers ranged from 3.5 to 7.1% for microcystin-LR, -RR, and -YR. The detection limits on high performance liquid chromatography (HPLC) with PDA detection for microcystins LR, RR, and YR were 24.7, 17.2, and 23.8 μg L−1 respectively, calculated as three times the signal to noise ratio. The rate of accumulation of most of the MC compounds tested was dependent on temperature and flow velocity. Furthermore, the sample matrix, e.g. humic substances, had no significant effect on the concentration of compounds trapped in the acceptor solution and once these MC compounds were trapped in the acceptor phase they did not diffuse back during the deployment period.
Skip Nav Destination
Article navigation
Research Article|
July 07 2015
Calibration of a passive, in situ, integrative sampler for monitoring of microbial biotoxins in aquatic environments Available to Purchase
Hlengilizwe Nyoni;
Hlengilizwe Nyoni
1University of South Africa, College of Science Engineering and Technology, Nanotechnology and Water Sustainability Research Unit, UNISA Science Campus, P.O. Box 392 UNISA 0003, 1709 Roodepoort, Johannesburg, Florida, South Africa
Search for other works by this author on:
Bhekie B. Mamba;
Bhekie B. Mamba
1University of South Africa, College of Science Engineering and Technology, Nanotechnology and Water Sustainability Research Unit, UNISA Science Campus, P.O. Box 392 UNISA 0003, 1709 Roodepoort, Johannesburg, Florida, South Africa
Search for other works by this author on:
Titus A. M. Msagati
1University of South Africa, College of Science Engineering and Technology, Nanotechnology and Water Sustainability Research Unit, UNISA Science Campus, P.O. Box 392 UNISA 0003, 1709 Roodepoort, Johannesburg, Florida, South Africa
E-mail: [email protected]
Search for other works by this author on:
Water Supply (2015) 15 (6): 1353–1367.
Article history
Received:
January 23 2015
Accepted:
May 28 2015
Citation
Hlengilizwe Nyoni, Bhekie B. Mamba, Titus A. M. Msagati; Calibration of a passive, in situ, integrative sampler for monitoring of microbial biotoxins in aquatic environments. Water Supply 1 December 2015; 15 (6): 1353–1367. doi: https://doi.org/10.2166/ws.2015.080
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00