The removal efficiency of particulate matter from a sedimentation basin with an inclined plate settler in drinking water treatment facilities is sometimes reduced by density flow caused by temperature increases in the raw water. In this study, the structure of the density flow and its prevention are investigated by means of three-dimensional computational fluid dynamics (CFD). The results of CFD show that upward velocity is uniform and normal operations are performed before the increase in inlet water temperatures. After the onset of a temperature increase in the raw water, the upward flow velocity on the inclined plate settler increases, especially in the upstream zone of the plate. This velocity increment has a strong correlation with increase in turbidity as a result of the overflow of particulate matter. The effects of the installation of baffle plates on the inclined plate settler to reduce turbidity were explored. The CFD results using baffle plates show a significant decrease in upward velocity on the inclined plate settler. This suggests that baffle plates are effective in suppressing the overflow of particulate matter. To verify the prediction by CFD, baffle plates were installed in a drinking water treatment facility. The results show that the turbidity of treated water was reduced by the proposed procedure.
Skip Nav Destination
Article navigation
Research Article|
January 31 2017
Influence of density flow on treated water turbidity in a sedimentation basin with inclined plate settler Available to Purchase
K. Takata;
1Department of Mechanical Engineering, National Institute of Technology, Kure College, 2-2-11, Agaminami, Kure, Hiroshima 737-8506, Japan
E-mail: [email protected]
Search for other works by this author on:
R. Kurose
R. Kurose
2Department of Mechanical Engineering and Science, Kyoto University, Kyoto daigaku-Katsura, Nishikyo-ku, Kyoto 615-8540, Japan
Search for other works by this author on:
Water Supply (2017) 17 (4): 1140–1148.
Article history
Received:
August 05 2016
Accepted:
January 16 2017
Citation
K. Takata, R. Kurose; Influence of density flow on treated water turbidity in a sedimentation basin with inclined plate settler. Water Supply 1 July 2017; 17 (4): 1140–1148. doi: https://doi.org/10.2166/ws.2017.012
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00