This paper presents an approach for assessing the risk of producing non-compliant drinking water (i.e. one of the quality parameters exceeds the standards fixed by legislation), taking into account the quality parameters of raw water and the process line of the treatment plant (technology, different failure mode and corresponding failure rate). Firstly, nominal and degraded modes of each step of the treatment line are analysed, in order to obtain transfer functions (which give output concentration of parameters in function of the input concentration) for each step of the treatment and each quality parameter, in nominal and degraded functioning. The transfer function of the whole treatment process can thereby be obtained by combination of transfer function of each step, and failure conditions of the whole treatment process and corresponding degraded global transfer function could be determined. Secondly, an inversion of both global function (nominal and degraded) permits to estimate probability for the resource to exceed thresholds fixed by regulation (in that case, a scenario of non-compliant drinking water exists), and to obtain a compliant water availability. Finally, this paper presents a software tool realised to evaluate the risk of non-compliant produced water, using the described methodology. Finally, an approach of risk assessment for Cryptosporidium is also presented. This method allows to identification and puts priorities for utilities presenting the highest risk.
Skip Nav Destination
Article navigation
Research Article|
July 01 2002
Risk assessment for drinking water production: assessing the potential risk due to the presence of Cryptosporidium oocysts in water Available to Purchase
J.M. Laîné;
J.M. Laîné
*Technical and Research Centre, Ondeo Services, 38 rue du président Wilson, 78230 Le Pecq, France
Search for other works by this author on:
S. Démotier;
S. Démotier
*Technical and Research Centre, Ondeo Services, 38 rue du président Wilson, 78230 Le Pecq, France
***Laboratoire SIME (Ondeo Services and UTC joined laboratory), BP 20529, 60205 Compiègne Cedex, France
Search for other works by this author on:
K. Odeh;
K. Odeh
*Technical and Research Centre, Ondeo Services, 38 rue du président Wilson, 78230 Le Pecq, France
***Laboratoire SIME (Ondeo Services and UTC joined laboratory), BP 20529, 60205 Compiègne Cedex, France
Search for other works by this author on:
W. Schön;
W. Schön
**Université de Technologie de Compiègne (UTC), BP 20529, 60205 Compiègne Cedex, France
***Laboratoire SIME (Ondeo Services and UTC joined laboratory), BP 20529, 60205 Compiègne Cedex, France
Search for other works by this author on:
P. Charles
P. Charles
*Technical and Research Centre, Ondeo Services, 38 rue du président Wilson, 78230 Le Pecq, France
Search for other works by this author on:
Water Supply (2002) 2 (3): 55–63.
Citation
J.M. Laîné, S. Démotier, K. Odeh, W. Schön, P. Charles; Risk assessment for drinking water production: assessing the potential risk due to the presence of Cryptosporidium oocysts in water. Water Supply 1 July 2002; 2 (3): 55–63. doi: https://doi.org/10.2166/ws.2002.0085
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00