Pilot testing was conducted at a brackish water reverse osmosis water treatment plant to identify operational constraints associated with effective scaling control. The test program involved testing select inhibitors/dispersants, feed water pH, and operating recovery as part of a full-scale retrofit from a hollow fiber to spiral-wound reverse osmosis membrane facility. The test results indicated the facility could be operated at elevated recovery, but was sensitive to conditioning with sulfuric acid. Use of sulfuric acid addition to control calcium carbonate scaling was determined to increase calcium sulfate scaling. Membrane autopsy data confirmed calcium sulfate scaling onto the membrane surface with minimal biological and organic content. It was determined that recovery could be increased from 65 to 75 percent by discontinuing sulfuric acid addition and feeding only scale inhibitor. Scale inhibitors with dispersant properties were recommended for full-scale implementation.
Skip Nav Destination
Article navigation
Research Article|
December 01 2003
Scale inhibitor and recovery optimization for a brackish water supply: pilot test results and full-scale experiences Available to Purchase
S. Duranceau;
*Boyle Engineering Corp., 320 E. South St., Orlando, FL 32801, USA
E-mail: [email protected]
Search for other works by this author on:
W.A. Lovins;
W.A. Lovins
*Boyle Engineering Corp., 320 E. South St., Orlando, FL 32801, USA
Search for other works by this author on:
J.V. Foster;
J.V. Foster
*Boyle Engineering Corp., 320 E. South St., Orlando, FL 32801, USA
Search for other works by this author on:
D. Taylor;
D. Taylor
**City of Sarasota, 1565 First Street, Sarasota, FL 34236, USA
Search for other works by this author on:
J. Morton;
J. Morton
**City of Sarasota, 1565 First Street, Sarasota, FL 34236, USA
Search for other works by this author on:
C. Morton
C. Morton
**City of Sarasota, 1565 First Street, Sarasota, FL 34236, USA
Search for other works by this author on:
Water Supply (2003) 3 (5-6): 139–145.
Citation
S. Duranceau, W.A. Lovins, J.V. Foster, D. Taylor, J. Morton, C. Morton; Scale inhibitor and recovery optimization for a brackish water supply: pilot test results and full-scale experiences. Water Supply 1 December 2003; 3 (5-6): 139–145. doi: https://doi.org/10.2166/ws.2003.0160
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00