Biofouling is a frequently occurring fouling mechanism in membrane applications. Controlling this phenomenon is a challenge due to the difficulty of cleaning biofouling in spiral wound membrane elements. It is assumed that cleaning can be more efficient when biofouling is in an early stage of colonisation. Therefore a sensitive method has to be available for an early identification of biofouling. The present method, the measurement of the normalised pressure drop (NPD) is not specific for biofouling and is not very sensitive. In this research the feasibility of the specific oxygen consumption rate for detection of the activity of biofilms was investigated in membrane systems. The method has the advantages to be specific for active biomass, applicable in situ, non-destructive and more sensitive than NPD. Three experiments demonstrated that the measurement of the rate of oxygen consumption is potentially a simple, reliable method for the measurement of the active biomass in membrane systems. During one of the experiments the method illustrated the effect of cleaning and the regrowth of bacteria afterwards. The method will be further evaluated and standardized. The relation between the specific oxygen consumption rate and the condition of the biofilm, measured by autopsy of membrane elements, will be further explored. The ongoing research will result in an apparatus and procedure, to be used for biofouling identification during the operation of full-scale and pilot plants.
Skip Nav Destination
Article navigation
Research Article|
December 01 2003
An in situ biofouling monitor for membrane systems Available to Purchase
J.W.N.M. Kappelhof;
*Kiwa N.V. Water Research, PO Box 1072, 3430 BB Nieuwegein, The Netherlands
E-mail: [email protected]
Search for other works by this author on:
H.S. Vrouwenvelder;
H.S. Vrouwenvelder
*Kiwa N.V. Water Research, PO Box 1072, 3430 BB Nieuwegein, The Netherlands
Search for other works by this author on:
J.C. Kruithof;
J.C. Kruithof
***NV PWN Water Supply Company North Holland, PO Box 2113, 1990 AC Velserbroek, The Netherlands
Search for other works by this author on:
D. van der Kooij;
D. van der Kooij
*Kiwa N.V. Water Research, PO Box 1072, 3430 BB Nieuwegein, The Netherlands
Search for other works by this author on:
J.C. Schippers
J.C. Schippers
*Kiwa N.V. Water Research, PO Box 1072, 3430 BB Nieuwegein, The Netherlands
****International Institute for Infrastructure, Hydraulics and Environmental Engineering, IHE Delft, P.O. Box 3015, 2601DA Delft, The Netherlands
Search for other works by this author on:
Water Supply (2003) 3 (5-6): 205–210.
Citation
J.W.N.M. Kappelhof, H.S. Vrouwenvelder, M. Schaap, J.C. Kruithof, D. van der Kooij, J.C. Schippers; An in situ biofouling monitor for membrane systems. Water Supply 1 December 2003; 3 (5-6): 205–210. doi: https://doi.org/10.2166/ws.2003.0168
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00