A new generation of high gradient magnetic separation (HGMS) has recently received attention again, especially for its applications in the field of water and wastewater treatment. The reason for this attention is that a newly developed superconducting magnet can be used to easily generate a high magnetic field, under which even weakly paramagnetic materials can be separated at high efficiency. We have developed a new wastewater treatment process using magnetic gel particles containing immobilized microorganisms and magnetic particles. The magnetic gel particles are separated and recovered from the effluent in water and wastewater treatment processes, and are then recycled to a bioreactor directly or reused after storing. In this research, a novel type of magnetic separator without a filter matrix was designed for the separation and recovery of magnetic gel particles with different magnetic characteristics. No backwashing is required for this new type of separator. By using the separator, polyethylene glycol (PEG) gel particles with 2% magnetite were continuously separated and recovered from the PEG gel particles with 0.04% magnetite at an efficiency of around 90%. The PEG gel particles containing nitrifying bacteria and magnetic particles were available for the oxidation of ammonia solution at a slightly lower nitrification rate than the PEG gel particles with nitrifying bacteria but without magnetite.
Skip Nav Destination
Article navigation
Research Article|
February 01 2004
A new wastewater treatment system recovering magnetically immobilized microorganisms under strong magnetic field Available to Purchase
H. Ozaki;
*Department of Civil Engineering, Osaka Sangyo University, 3-1-1, Nakagaito, Daito, Osaka 574-8530, Japan (E-mail: [email protected])
E-mail: [email protected]
Search for other works by this author on:
S. Kurinobu;
S. Kurinobu
**Department of Electronic and Electrical Engineering, Fukuyama University, 1-banchi, Gakuencho, Fukuyama, Hiroshima 729-0292, Japan (E-mail: [email protected])
Search for other works by this author on:
T. Watanabe;
T. Watanabe
***Department of Electrical Engineering, Graduate School of Engineering, Tokyo Metropolitan University, 1-1 Minami Osawa, Hachioji, Tokyo, 192-0397, Japan (E-mail: [email protected])
Search for other works by this author on:
S. Nishijima;
S. Nishijima
****Department of Nuclear Engineering, Graduate School of Engineering, Osaka University, Yamadaoka 2-1, Suita, Osaka, 565-0871, Japan (E-mail: [email protected])
Search for other works by this author on:
T. Sumino
T. Sumino
*****Matsudo Research Laboratory, Hitachi Plant Engineering & Construction Co., Ltd., 537 Kami-Hongo Matsudo, Chiba 271-0064, Japan (E-mail: [email protected])
Search for other works by this author on:
Water Supply (2004) 4 (1): 47–54.
Citation
H. Ozaki, S. Kurinobu, T. Watanabe, S. Nishijima, T. Sumino; A new wastewater treatment system recovering magnetically immobilized microorganisms under strong magnetic field. Water Supply 1 February 2004; 4 (1): 47–54. doi: https://doi.org/10.2166/ws.2004.0006