An ozone reaction model combined with CFD (Computational Fluid Dynamics) technique was developed in this research. In the simulation of ozonation, hydrodynamic behavior caused by bubbling of ozone contacting-gas is important as well as reaction kinetics. CFD technique elucidated hydrodynamic behavior in the selected ozone contactor, which consisted of three main chambers. Back-mixing zone was found in each chamber. The higher velocities of water were observed in the second and third chambers than that in the first one. The flow of the opposite direction to the main flow was observed near the water surface. Based on the results of CFD simulation, each chamber was divided into small compartments, and hydrodynamic behavior and effective volume were discussed. Mass balance equations were also established in each compartment with reaction terms associated with DOC, odor compounds, bacteria, bromide ion and bromate ion. This reaction model was intended to predict dissolved ozone concentration, especially. We concluded that the model could predict favourably the mass balance of ozone, namely absorption efficiency of gaseous ozone, dissolved ozone concentration and ozone consumption. After establishing the model, we discussed the effects of hydrodynamic behavior on dissolved ozone concentration.
Skip Nav Destination
Article navigation
Research Article|
December 01 2004
Evaluating effective volume and hydrodynamic behavior in a full-scale ozone contactor with computational fluid dynamics simulation Available to Purchase
T. Mizuno;
*Department of Urban and Environmental Engineering, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-8501, Japan
E-mail: [email protected]
Search for other works by this author on:
N.-S. Park;
N.-S. Park
*Department of Urban and Environmental Engineering, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-8501, Japan
Search for other works by this author on:
H. Tsuno;
H. Tsuno
*Department of Urban and Environmental Engineering, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-8501, Japan
Search for other works by this author on:
T. Hidaka
T. Hidaka
*Department of Urban and Environmental Engineering, Kyoto University, Yoshida-honmachi, Sakyo-ku, Kyoto 606-8501, Japan
Search for other works by this author on:
Water Supply (2004) 4 (5-6): 277–288.
Citation
T. Mizuno, N.-S. Park, H. Tsuno, T. Hidaka; Evaluating effective volume and hydrodynamic behavior in a full-scale ozone contactor with computational fluid dynamics simulation. Water Supply 1 December 2004; 4 (5-6): 277–288. doi: https://doi.org/10.2166/ws.2004.0118
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00