The current paper reports the investigation of two transient-based techniques for leak detection in water pipe systems using physical data collected in the laboratory and in quasi-field conditions. The first is the analysis of the leak reflected wave during a transient event and the second is inverse transient analysis (ITA). This was approached through the development of an inverse transient analysis tool and the collection of transient data for the testing and validation of this model. Two experimental programmes were carried out at Imperial College and in cooperation with Thames Water for the validation and testing of these techniques. Evaluation of the presence, location and size of leaks was carried out using the collected data. Transient-based techniques have been shown to be successful in the detection and location of leaks and leak location uncertainties depended on the leak size and location, flow regime and location where the transient event was generated. These leak detection methods are very promising for identifying the general area of the trunk main with leakage, and can be combined with other leak location techniques (e.g. acoustic equipment) to more precisely pinpoint the leak position. Transient-based techniques are particularly important for the diagnosis, monitoring and control of existing water supply systems, not only to detect leaks, but also to better understand the causes of pipe bursts and accidents, particularly when these are due to natural transient events.
Skip Nav Destination
Article navigation
Research Article|
December 01 2004
Application of hydraulic transients for leak detection in water supply systems Available to Purchase
D. Covas;
*Civil Eng. Dept., Instituto Superior Técnico, Av. Rovisco Pais, 1049-001 Lisbon, Portugal (E-mail: [email protected]; [email protected])
E-mail: [email protected]
Search for other works by this author on:
H. Ramos;
H. Ramos
*Civil Eng. Dept., Instituto Superior Técnico, Av. Rovisco Pais, 1049-001 Lisbon, Portugal (E-mail: [email protected]; [email protected])
Search for other works by this author on:
N. Graham;
N. Graham
**Civil and Environ. Eng. Dept., Imperial College, Imperial College Road, SW7 2BU, London, UK (E-mail: [email protected]; [email protected])
Search for other works by this author on:
C. Maksimovic
C. Maksimovic
**Civil and Environ. Eng. Dept., Imperial College, Imperial College Road, SW7 2BU, London, UK (E-mail: [email protected]; [email protected])
Search for other works by this author on:
Water Supply (2004) 4 (5-6): 365–374.
Citation
D. Covas, H. Ramos, N. Graham, C. Maksimovic; Application of hydraulic transients for leak detection in water supply systems. Water Supply 1 December 2004; 4 (5-6): 365–374. doi: https://doi.org/10.2166/ws.2004.0127
Download citation file:
Sign in
Don't already have an account? Register
Client Account
You could not be signed in. Please check your email address / username and password and try again.
Could not validate captcha. Please try again.
eBook
Pay-Per-View Access
$38.00